• Title/Summary/Keyword: Ultrasound Diagnosis

Search Result 539, Processing Time 0.023 seconds

A Study on Pulse Pattern Using Ultrasonic Device (초음파기기를 이용한 맥상(脈象) 연구)

  • Kim, Hee Young;Park, Jeongbin;Keum, Yujeong;Yeo, Inkeum;Eom, Dongmyung;Song, Jichung
    • Journal of Korean Medical classics
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2021
  • Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.

Hepatic Encephalopathy in a Connemara Pony

  • Park, Kyung-won;Lee, Eun-bee;Park, Young-jae;Jung, Ji-Youl;Kim, Jae-Hoon;Jeong, Hyohoon;Seo, Jong-pil
    • Journal of Veterinary Clinics
    • /
    • v.38 no.6
    • /
    • pp.299-304
    • /
    • 2021
  • A 3-year-old female Connemara pony was referred to Jeju National University Equine Hospital because of weight loss and prolonged anorexia. On admission, heart and respiratory rates were slightly elevated while body temperature was within the normal range. The color of the conjunctival and oral mucosa was yellowish pink. The blood chemistry results showed that total bilirubin, aspartate aminotransferase, and gamma-glutamyl transferase levels were remarkably elevated while blood urea nitrogen was within the reference range. Transcutaneous abdominal ultrasound revealed an enlarged right lobe of the liver with prominently increased parenchymal echogenicity, reduced hepatic vessels, and rounded caudal border. The pony was tentatively diagnosed with chronic hepatitis and icterus; rest and supportive treatments were provided. Clinical signs aggravated on day 2 with hind quarter paresis and cranial nerve signs such as circling, drooping, jerking, and head pressing against walls. Recumbency and generalized ataxia (grade 5/5) were shown on day 3. Plasma ammonia concentration on day 3 was as high as 656 µmol/L. Necropsy and histopathologic examinations strongly supported a diagnosis of hepatic encephalopathy. This case of hepatic encephalopathy exhibited rapid progress from low to terminal grade within 4 days in a Connemara pony. The results provide well-established clinical and pathological data for future application.

Dual-mode diagnosis system for water quality and corrosion in pipe using convolutional neural networks (CNN) and ultrasound (합성곱 신경망과 초음파 기반 상수도관 수질 및 부식 분석용 이중모드 진단 시스템)

  • So Yeon Moon;Hyeon-Ju Jeon;Yeongho Sung;Min-Seo Kim;Daehun Kim;Jaeyeop Choi;Junghwan Oh;O-Joun Lee;Hae Gyun Lim
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.685-686
    • /
    • 2023
  • 상수도관의 수질 및 부식도 검사에는 파이프에 손상을 입히지 않고 지속적인 방법이 필요하다. 초음파는 이를 만족하면서 상태를 확인할 수 있고 주파수가 높을수록 해상도가 좋아져 정밀한 측정이 가능하다는 장점이 있다. 이러한 특성을 이용해 상수도관 모니터링 시스템으로 초음파 기반의 Scanning Acoustic Microscopy(SAM)과 Convolutional Neural Network(CNN)을 사용하는 새로운 방법을 제안한다. 기존의 Non-Destructive Testing(NDT)방식의 단점을 보완하면서 더 높은 해상도로 상수도관을 점검하는 방식으로, SAM 을 이용하여 부식으로 인한 파이프 두께 변화와 부유물의 여부 및 수질을 동시에 감지하고 얻은 데이터를 CNN 으로 분석했다. CNN 의 높은 정확도 결과로 이 시스템의 파이프 부식도 및 수질 모니터링에 대한 적합성을 보여주었다.

A Case Report of Axillary Hibernoma: US, CT, MR, and Histopathologic Findings (액와부 갈색지방종의 증례 보고: 초음파, 컴퓨터단층촬영, 자기공명영상, 병리 소견)

  • Ji Yeon Park;Seong Yoon Yi;Ji Young Lee;Tae Jung Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.439-443
    • /
    • 2022
  • Hibernoma is a rare benign tumor of brown adipose tissue. Herein, we report a case of axillary hibernoma in a 53-year-old female and discuss the various radiologic findings. The US revealed a 4.5-cm well-defined oval heterogenous hyperechoic mass in the right axilla with anterior displacement of the axillary vessels. Non-enhanced chest CT showed a 5.0-cm well defined, oval, and low-attenuated mass. MRI demonstrated a 5.5-cm mass with heterogeneous intermediate-to-high signal intensity on T1-and T2-weighted images and irregular enhancement at the peripheral portion. The patient underwent an US-guided core needle biopsy and the final diagnosis was hibernoma.

MRI Findings and Differential Diagnosis of Benign and Malignant Tumors of the Uterine Corpus (자궁체부의 양성 및 악성 종양의 자기공명영상 소견과 감별 진단)

  • Jihyun Kim;Suk Hee Heo;Sang Soo Shin;Yong Yeon Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1103-1123
    • /
    • 2021
  • The uterus can be largely divided into the uterine corpus and uterine cervix. Diseases that can occur in the uterine corpus, composed of the endometrium and myometrium, vary from benign to malignant tumors. Ultrasound and CT are the primary non-invasive evaluation methods to differentiate between benign and malignant tumors, but in some cases, they are difficult to differentiate due to their non-specific imaging findings. However, magnetic resonance imaging (MRI), which has high resolution, helps not only in locating lesions but also in evaluating histological characteristics and staging of malignant tumors. In this review article, the characteristic MRI findings that radiologists should be aware of regarding various benign and malignant tumors detected in the uterine corpus are summarized with their points of differentiation.

Variations of Speed of Sound and Attenuation Coefficient with Porosity and Structure in Bone Mimics (뼈 모사체에서 다공율 및 구조에 대한 음속 및 감쇠계수의 변화)

  • Kim, Seong-Il;Choi, Min-Joo;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.388-394
    • /
    • 2010
  • In the present study, polyacetal bone mimics with circular cylindrical pores were used to investigate variations of speed of sound and attenuation coefficient with porosity and microarchitecture in bone. The speed of sound and attenuation coefficient of the 6 bone mimics with porosities from 0 % to 65.9 % were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. Independently of the structural properties of the bone mimics, the speed of sound decreased almost linearly with the increasing porosity. The attenuation coefficient measured at 1.0 MHz exhibited linear or nonlinear correlations with the porosity, depending on the structural properties of the bone mimics. These results are consistent with those previously published by other researchers using bone samples and mimics, and advances our understanding of the relationships of the ultrasonic parameters for the diagnosis of osteoporosis with the bone density and microarchitecture in human bones.

Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler (혈관협착팬텀의 제작 및 파워도플러의 영상 평가)

  • Park, Hee-Young;Bae, Jong-Rim;Kim, Jeong-Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.732-739
    • /
    • 2009
  • Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.

Granular Cell Tumor of the Axillary Accessory Breast: A Case Report (액와부 부유방에 발생한 과립 세포 종양: 증례 보고)

  • Youn Joo Jung;Kyung Jin Nam;Ki Seok Choo;Kyeyoung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.275-279
    • /
    • 2023
  • Granular cell tumors (GCTs) are rare benign soft tissue tumors that can occur throughout the body, particularly the head and neck; only 5%-8% of GCTs occur in the breast. We report a case of a GCT of the axillary accessory breast, which is a rare location of this tumor. A 50-year-old woman had a 2-month history of a palpable mass in the left axilla. Physical examination, as well as mammographic and ultrasonographic findings suggested a breast malignancy. Histopathological examination showed a benign GCT, and wide local excision was performed. The patient has remained disease-free over 2 years postoperatively. Although most GCTs are benign, wide complete resection of the tumor and follow-up are required considering the possibility of recurrence. The radiologist should know the characteristics of GCTs as a differential diagnosis of breast and axillary lesions to prevent unnecessary treatment.

Concurrent Torsion of the Caudate Liver Lobe and Spleen in a German Shepherd Dog

  • Seong-won An;Seung-Min Hwang;Il-Gwon Jung;Sang-Kwon Lee;Young-Sam Kwon
    • Journal of Veterinary Clinics
    • /
    • v.41 no.1
    • /
    • pp.30-36
    • /
    • 2024
  • A 3-year-old, 20.6 kg, neutered male German Shepherd dog was referred to Kyungpook National University Veterinary Medicine Teaching Hospital. Clinical examination revealed chronic diarrhea for 6 weeks and a non-tender, distended abdomen without lethargy, anorexia, and vomiting. Diarrhea was watery and had a waxing and waning course despite symptomatic treatment. A complete blood count identified mild leukocytosis and mild anemia. Serum biochemistry analysis showed elevated alanine aminotransferase and aspartate aminotransferase levels, and mild hypoalbuminemia. Abdominal ultrasound examination revealed mixed echogenicity with absent blood flow at the caudate process of the caudate liver lobe and a small amount of ascites. Computed tomography revealed torsion of the caudate process of the caudate liver lobe and spleen and gas dilatation of the intestine. After establishing a diagnosis of organ torsion on imaging, we deemed the condition an emergency and immediately performed surgery. Given that laparotomy confirmed organ torsion, liver lobectomy, total splenectomy, and prophylactic gastropexy were conducted. The patient was discharged 11 days after surgery without complications. In general, liver lobe torsion and splenic torsion are uncommon in dogs and present with nonspecific clinical signs, such as abdominal pain, lethargy, anorexia, and vomiting. In the current case, torsion of the caudate liver lobe and spleen occurred without other clinical signs except for a distended abdomen. Moreover, no reports in dogs have demonstrated the simultaneous occurrence of both diseases.

Clinical Utility of Chest Sonography in Chronic Obstructive Pulmonary Disease Patients Focusing on Diaphragmatic Measurements

  • Hend M. Esmaeel;Kamal A. Atta;Safiya Khalaf;Doaa Gadallah
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.80-90
    • /
    • 2024
  • Background: There are many methods of evaluating diaphragmatic function, including trans-diaphragmatic pressure measurements, which are considered the key rule of diagnosis. We studied the clinical usefulness of chest ultrasonography in evaluating stable chronic obstructive pulmonary disease (COPD) patients and those in exacerbation, focusing on diaphragmatic measurements and their correlation with spirometry and other clinical parameters. Methods: In a prospective case-control study, we enrolled 100 COPD patients divided into 40 stable COPD patients and 60 patients with exacerbation. The analysis included 20 age-matched controls. In addition to the clinical assessment of the study population, radiological evaluation included chest radiographs and chest computed tomography. Transthoracic ultrasonography (TUS) was performed for all included subjects. Results: Multiple A lines (more than 3) were more frequent in COPD exacerbation than in stable patients, as was the case for B-lines. TUS significantly showed high specificity, negative predictive value, positive predictive value, and accuracy in detecting pleural effusion, consolidation, pneumothorax, and lung mass. Diaphragmatic measurements were significantly lower among stable COPD subjects than healthy controls. Diaphragmatic thickness and excursion displayed a significant negative correlation with body mass index and the dyspnea scale, and a positive correlation with spirometry measures. Patients in Global Initiative for Chronic Obstructive Lung Disease (GOLD) group D showed lower diaphragmatic measurements (thickness and excursion). Conclusion: The TUS of COPD patients both in stable and exacerbated conditions and the assessment of diaphragm excursion and thickness by TUS in COPD patients and their correlations to disease-related factors proved informative and paved the way for the better management of COPD patients.