• Title/Summary/Keyword: Ultrasonography imaging

Search Result 539, Processing Time 0.02 seconds

Diagnostic Imaging of Paraprostatic Cyst with Osseous Metaplasia in a Dog (개에서 골화생을 동반한 전립선 주위종의 영상의학 증례)

  • Choi, Ji-Hye;Keh, Seo-Yeon;Kim, Sung-Soo;Choi, Hee-Yeon;Kim, Hyun-Wook;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.468-473
    • /
    • 2010
  • A 6-year-old intact male Doberman pinscher presented with a thin soft stool and urinary signs. On radiography, three masses were observed in the caudal abdomen. One mass was described as a large, round, mineralized mass, with an "eggshell" appearance. The second mass was located caudal to the mineralized mass, and the third mass was located between the two masses. The second and the third masses had a soft tissue density. Ultrasonography was performed to identify the features and the origins of the masses. The first mass contained a large amount of anechoic fluid and had a thin wall; it was determined to be a cyst. Strong acoustic shadowing artifact was created by the mineralized cystic wall. Caudal to the cyst, the second mass was shown to be the prostate. A hypoechoic stalk connected the prostate and the cyst, which represented the cyst as a paraprostatic cyst with mineralization. The third mass was the normal urinary bladder. The cyst was removed surgically and confirmed by histopathologic examination. This report described typical clinical findings, diagnostic imaging, and treatment of a paraprostatic cyst.

Medical Imaging of Pyothorax in a Dog (개에서 농흉증의 영상의학적 접근)

  • Choi, Ho-Jung;Lee, Young-Won;Park, Ki-Tae;Wang, Ji-Hwan;Kim, Young-Ki;Yeon, Seong-Chan;Lee, Hyo-Jong;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.107-112
    • /
    • 2010
  • A 3-years-old female Pointer was evaluated for anorexia, dyspnea and exercise intolerance for 10 days. Auscultation revealed muffling of heart sound. There were leukocytosis, anemia, hypoalbuminaemia and hyperglobulinaemia on the blood profiles. Radiography showed severe pleural effusion. Thorax ultrasonographs described traped pleural effusion, pericardial effusion and collapsed right lung lobe(s). On CT images, thoracic neoplasia and lung torsion were ruled-out. Thoracocentesis with thoracoscopy and bacterial culture revealed pyothorax and pleuritis. The diagnosis of pyothorax in dogs and cats is based on clinical signs, radiography, thoracocentesis and cytology and culture of the exudate. In this case, various diagnostic medical imaging techniques (radiography, ultrasonography, CT and thoracoscopy) were used for diagnosis of pyothorax.

Neonatal Intracranial Ischemia and Hemorrhage : Role of Cranial Sonography and CT Scanning

  • Khan, Imran Ahmad;Wahab, Shagufta;Khan, Rizwan Ahmad;Ullah, Kkram;Ali, Manazir
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.89-94
    • /
    • 2010
  • Objective : To evaluate the role of cranial sonography and computed tomography in the diagnosis of neonatal intracranial hemorrhage and hypoxic-ischemic injury in an Indian set-up. Methods : The study included 100 neonates who underwent cranial sonography and computed tomography (CT) in the first month of life for suspected intracranial ischemia and hemorrhage. Two observers rated the images for possible intracranial lesions and a kappa statistic for interobserver agreement was calculated. Results : There was no significant difference in the kappa values of CT and ultrasonography (USG) for the diagnosis of germinal matrix hemorrhage/intraventricular hemorrhage (GMH/IVH) and periventricular leucomalacia (PVL) and both showed good interobserver agreement. USG, however detected more cases of GMH/IVH (24 cases) and PVL (19) cases than CT (22 cases and 16 cases of IVH and PVL, respectively). CT had significantly better interobserver agreement for the diagnosis of hypoxic ischemic injury (HII) in term infants and also detected more cases (33) as compared to USG (18). CT also detected 6 cases of extraaxial hemorrhages as compared to 1 detected by USG. Conclusion : USG is better modality for imaging preterm neonates with suspected IVH or PVL. However, USG is unreliable in the imaging of term newborns with suspected HII where CT or magnetic resonance image scan is a better modality.

Two cases of female hydrocele of the canal of nuck

  • Choi, Yu-Mi;Lee, Gyu-Min;Yi, Jung-Bin;Yoon, Kyung-Lim;Shim, Kye-Shik;Bae, Chong-Woo;Choi, Sung-Il;Kim, Hyun-Cheol
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.4
    • /
    • pp.143-146
    • /
    • 2012
  • The processus vaginalis within the inguinal canal forms the canal of Nuck, which is a homolog of the processus vaginalis in women. Incomplete obliteration of the processus vaginalis causes indirect inguinal hernia or hydrocele of the canal of Nuck, a very rare condition in women. Here, we report 2 cases of hydrocele of the canal of Nuck that were diagnosed with ultrasonography in both cases and magnetic resonance imaging in 1 case to confirm the sonographic diagnosis. High ligation and hydrocelectomy were conducted in both patients. In 1 patient, 14 months later, the occurrence of contralateral inguinal hernia was suspected, but did not require surgery. The other patient had a history of surgery for left inguinal hernia 11 months before the occurrence of right hydrocele of the canal of Nuck. In both cases, the occurrence of an inguinal hernia on the contralateral side was noted.

Arteriovenous Malformation on the Medial Plantar Area of the Foot: A Case Report (족저 내측부의 동정맥 기형: 증례 보고)

  • Ha, Dae-Ho;Kwon, Jung-Nam;Kim, Yu-Mi;Lee, Jun-Hyung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.4
    • /
    • pp.187-191
    • /
    • 2016
  • Arteriovenous malformation (A-V malformation) is defined as an abnormal connection between arteries and veins that lead to A-V shunting with an intervening network of vessels. A-V malformation is a rare condition, and spontaneous regression is also rare. A-V malformation becomes symptomatic when the surrounding tissue and osseous structures are negatively affected. A-V malformation has a high recurrence rate and is relatively hard to treat. In this case, a huge mass with pulsatile and bruit on the medial plantar area were observed. With the diagnosis of A-V malformation in accordance with the results from ultrasonography, magnetic resonance imaging and computed tomography angiography, and mass excision with feeding vessel ligation through plantar midfoot approach was completed successfully.

Herlyn-Werner-Wunderlich Syndrome with Central Precocious Puberty: A Case Report

  • Han, Jeeho;Lee, Jae Man;Kim, Geon Hee;Kim, Su Jin
    • Childhood Kidney Diseases
    • /
    • v.23 no.2
    • /
    • pp.124-127
    • /
    • 2019
  • Herlyn-Werner-Wunderlich (HWW) syndrome is a rare congenital anomaly of the genitourinary tract comprising uterus didelphys, obstructed hemivagina, and ipsilateral renal agenesis. Patients with HWW syndrome usually present symptoms such as dysmenorrhea, abdominal pain, pelvic mass, and purulent vaginal discharge. If not treated at an appropriate time, complications such as infertility, endometriosis, pyosalpinx, and subsequent pelvic adhesions may occur. Here, we report a case of HWW syndrome in a 7-year-old-girl who was also diagnosed as having central precocious puberty. She was brought to the pediatric department with chief complaints of lump in her breast and vaginal discharge. When she was around 2 months old, she was confirmed to have a single kidney on ultrasonography. We checked her past medical history and diagnosed her as having HWW syndrome based on the results of imaging studies, including abdominal ultrasonography and pelvic magnetic resonance imaging. She underwent treatment with gonadotropin-releasing hormone analogue for 2 years. During 24 months of follow-up, she showed no serious problems or complications. If renal anomalies are identified immediately after birth or in infancy, further screening tests should be conducted prior to menstruation for determining congenital abnormalities of the reproductive tract and vice versa.

Incidentally found unicentric plasma cell variant Castleman's disease in mesentery: focus on ultrasonography and CT findings (우연히 발견된 장간막의 단중심성 형질세포형 Castleman병 1예: 초음파와 CT 소견 중심으로)

  • Kim, Hyun Min;Kim, Bong Soo;Jung, In Ho;Hyun, Chang Lim;Jung, Seung Wook;Jo, Jae Min
    • Journal of Medicine and Life Science
    • /
    • v.15 no.1
    • /
    • pp.19-22
    • /
    • 2018
  • Castleman's disease is a benign lympho-proliferative disorder that commonly occurs in mediastinum. It is known that the disease rarely occurs in mesentery. Most localized abdominal Castleman's diseases are histologically hyaline vascular type. The contrast-enhanced CT in patient with hyaline vascular type Castleman's disease shows a well-defined mass with homogenously intense enhancement. On the other hand, the patient with plasma cell variant has systemic symptoms, but not specific imaging features. We report a unicentric plasma cell variant Castleman's disease in mesentery nearby superior mesenteric artery as presenting a single mass, not accompanied by systemic symptoms with similar characteristics to hyaline vascular type.

Robotized Percutaneous Biopsy (로봇을 이용한 경피 생체 검사)

  • Son, Jaebum;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.105-113
    • /
    • 2012
  • Biopsy is a type of histopathological examinations, in which a physician samples cells or tissues from a patient's suspicious lesion. Such a lesion frequently resides deep inside human body, and then a percutaneous biopsy is therefore performed using a thick needle with the assistance of medical imaging such as computed tomography(CT) and magnetic resonance imaging(MRI). Recently modern robotic technology is being introduced to percutaneous biopsy in order to reduce any possible human error and hazard on physicians caused by medical imaging. After medical imaging locates the exact location of lesion, an optimization algorithm plans the path for a biopsy needle. Subsequently, a robot system moves the biopsy needle to the lesion in accurate and safe way with the control of a practitioner or automatically. In this article, we try to look into the state-of-art of percutaneous biopsy using such robotic technology. We classified percutaneous biopsy robots by mechanical characteristics and by imaging technology. Then, advantage and disadvantage of each class type are described as well as the basic description, and a few representative designs for each type are introduced. Current research issues of robotized percutaneous biopsy are subjectively selected for the readers' convenience. We emphasize the basic technology of actuator and sensors compatible with imaging technology to conclude this review.

Image Evaluation and Association Analysis of the Cardiovascular Disease of the Degree of Pancreatic Steatosis in Ultrasonography

  • Cho, Jin-Young;Ye, Soo-Young;Ko, Seong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • Increasing fat tissue of obese people, increases the rate of cardiovascular disease, diabetes, metabolic syndromes and dyslipidemia. An increase in the focal tissue of pancreas is a known risk factor of these diseases. Although there exists sufficient research on the diagnosis and treatment of pancreatic cancer, studies have been done on fatty pancreas. In this study, based on ultrasound imaging and using a texture characteristic of GLCM, fatty pancreas was divided into three categories: mild, moderate and severe. We compared and analyzed the three groups was by Pancreatic ultrasonography and body characteristics, serological tests, pressure and the degree of arteriosclerosis, against normal control group. The following parameters of control and test groups were measured: WC (waist circumference),BMI (body mass index), TC (total cholesterol), TG (triglyceride), HDL-C (High-density lipoprotein cholesterol) and LDL-C (Low-density lipoprotein cholesterol), SBP (systolic blood pressure), BST (Blood Sugar Test) and aortic PWV (pulse wave velocity). We observed the values correspondingly increasing fat deposition. However, ABI (Ankle Brachial pressure index) stenosis and HDL-C levels decreased with increasing fat deposit (p <0.05); a drop in these parameters are known to be harmful to the human body. The difference in texture characteristics between normal control group and pancreatic fatty group (mild, moderate, and severe) was statistically confirmed. Ultrasound imaging of pancreatic steatosis categorized the disease as mild, moderate and severe based on the characteristic texture. In conclusion, we observed on increase in metabolic syndrome, dyslipidemia, and arteriosclerosis, proportional to the degree of pancreatic fat deposition. The escalation of these diseases was confirmed and was directly related with predictors of cardiovascular diseases.

A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography (조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법)

  • Kim, Ho Joon;Gwak, Seong Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.