• Title/Summary/Keyword: Ultrasonography (US)

Search Result 190, Processing Time 0.026 seconds

Use of office-based ultrasonography for soft tissue lesions : A report of 3 cases with literature review (안면부 연조직 진단에서 외래기반 초음파의 사용 : 증례 보고(3례) 및 문헌 고찰)

  • Kim, Jae-Young;Kim, Min-Kyu;Lee, Sung-Hwa;Kim, Hyung Jun;Nam, Woong
    • The Journal of the Korean dental association
    • /
    • v.53 no.2
    • /
    • pp.143-152
    • /
    • 2015
  • Ultrasonography is relatively inexpensive, non-invasive imaging tool and provides real-time imaging. In addition, the images can be obtained repeatedly. But it is not widely used by dentists because it is hard to interpret and technique sensitive. Above all, ultrasonography cannot be used for hard tissue diagnosis. However, ultrasonography can be applied for diagnosis of infection, soft tissue tumor and inflammatory muscle diseases which are commonly found in dental outpatients. Generally, it shows well-defined border, hypoechoic and homogenous structure in case of benign tumor. Malignant tumor appears relatively irregular margin and heterogenous structure. Cyst represents relatively echo-free features compared with benign tumor. Although the general characteristics of abscess are similar with benign tumor, we can observe an increased vascularity and different clinical features. The purpose of this report is to present 3 cases of US images using office-based ultrasonography with their features and discuss the role of office-based ultrasound in dentistry for diagnosis of soft tissue lesions with literature review.

Ultrasonographic Evaluation of Renal Cortex and Outer Medulla Thickness in Dogs with Chronic Kidney Disease

  • Lee, Siheon;Hong, Sungkyun;Kim, Hyejin;Oh, Dayoung;Kim, Seungji;Choen, Sangkyung;Choi, Mincheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.34 no.3
    • /
    • pp.208-212
    • /
    • 2017
  • This study was performed to retrospectively pursue any correlation between renal cortex thickness (RCT), outer medulla thickness (OMT) on ultrasonography (US) and chronic kidney disease (CKD) with International Renal Interest Society (IRIS) stage. Medical records and US findings of the dogs diagnosed CKD were reviewed for comparing to those of the clinically healthy dogs from March. 2015 through June. 2016. To evaluate the correlation about normal and CKD patients, RCT and the OMT were measured on US images. RCT and OMT were adjusted by dividing body surface area for standardization (RCTS, OMTS). Also the ratio of RCT/OMT were calculated and these indices were evaluated to investigate any tendency between 5 groups (normal and 4 IRIS stages) using Jonckheere-Terpstra trend test (J-T test). The RCTS showed a declining tendency (p < 0.02) and the OMTS showed an inclining tendency from normal through each IRIS stage (p < 0.01). The RCT/OMT showed also declining tendency (p < 0.01). Although the gold standard for renal function including GFR is lack, it is thought that differentiation between normal and CKD patients could be possible on US measurement of renal cortex and outer medulla thickness, which could be an alternative index for kidney function in diagnostic imaging.

Usefulness of Serial Ultrasonography of the Rotator Cuff Repair (회전근 개 파열의 수술적 치료시 초음파 연속 검사의 유용성)

  • Park, Jae-Hyun;Choi, Won-Ki;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.78-85
    • /
    • 2008
  • Purpose: The findings of preoperative magnetic resonance imaging (MRI) and ultrasonography (US) examination in the diagnosis of rotator cuff tear were then compared with the findings of arthroscopic examination, and to evaluate the postoperative integrity of rotator cuff using serial US examination. Methods: Between February and May 2008, 29 patients with rotator cuff tear had undergone preoperative US and MRI examination and subsequent arthroscopic examination. And the results of MRI and US were compared with intra-operative results of the arthroscopic examination. We observed the postoperative integrity of rotator cuff using serial (postoperative 2 weeks, 6 weeks, 3 months) US examination. Results: The sensitivity of US and MRI for identifying rotator cuff tear were 100% and 100%. The sensitivity of US and MRI were 95% and 82% in full thickness tear, and 50%, 33% in partial thickness tear, respectively. Overall accuracy of US and MRI were 86%, 69%. Among 22 patients were operated for full thickness tear, intra-operative gap formation was identified in 11 patients (50%, small to medium 2 cases, large to massive 9 cases) which were identified at 2 weeks postoperative US. We could find 5 re-tears (23%, small to medium 1 case, large to massive 4 cases) on 6 weeks postoperative US after passive range of motion (ROM) exercise, and could also find 7 re-tears (32%, small to medium 2 cases, large to massive 5 cases)on 3 months postoperative US after active ROM exercise. Conclusion: Serial US after arthroscopic rotator cuff repair was useful to differentiate intra-operative gap formation from postoperative re-tear. We found 5 retears (23%) at 6 weeks and 7 retears (32%) at 3 months postoperative US, it was useful to make treatment plan during postoperative rehabilitation.

  • PDF

Fascicular Involvement of the Median Nerve Trunk in the Upper Arm: Manifestation as Anterior Interosseous Nerve Syndrome With Unique Imaging Features

  • Jae Eun Park;Darryl B. Sneag;Yun Sun Choi;Sung Hoon Oh;SeongJu Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.449-458
    • /
    • 2024
  • Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.

Imaging of Scrotal Tumors (음낭 종양의 영상 소견)

  • Seungsoo Lee;Young Taik Oh;Dae Chul Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1053-1065
    • /
    • 2021
  • Ultrasonography is effective for imaging superficial organs, such as the scrotum. Using a highfrequency transducer, ultrasonography can identify the location and characteristics of scrotal lesions with high accuracy. The primary role of ultrasound (US) in the evaluation of a scrotal mass is to determine if it is intratesticular or extratesticular. Additional clinical information and other imaging options may be needed to diagnose benign tumors and pseudo-tumors. MRI is an effective problem-solving tool in cases with nondiagnostic US findings. CT is helpful for staging testicular cancer and localizing undescended testis. This review covers the imaging features of testicular and extratesticular tumors.

Diagnostic Accuracy of Ultrasonography in Differentiating Benign and Malignant Thyroid Nodules Using Fine Needle Aspiration Cytology as the Reference Standard

  • Alam, Tariq;Khattak, Yasir Jamil;Beg, Madiha;Raouf, Abdul;Azeemuddin, Muhammad;Khan, Asif Alam
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.10039-10043
    • /
    • 2014
  • Background: In Pakistan thyroid cancer is responsible for 1.2% cases of all malignant tumors. Ultrasonography (US) is helpful in detecting cancerous thyroid nodules on basis of different features like echogenicity, margins, microcalcifications, size, shape and abnormal neck lymph nodes. We therefore aimed to calculate diagnostic accuracy of ultrasound in detection of carcinoma in thyroid nodules taking fine needle aspiration cytology as the reference standard. Materials and Methods: A cross-sectional analytical study was designed to prospectively collect data from December 2010 till December 2012 from the Department of Radiology in Aga Khan University Hospital, Karachi, Pakistan. A total of 100 patients of both genders were enrolled after informed consent via applying non-probability consecutive sampling technique. Patients referred to Radiology department of Aga Khan University to perform thyroid ultrasound followed by fine-needle aspiration cytology of thyroid nodules were included. They were excluded if proven for thyroid malignancy or if their US or FNAC was conducted outside our institution. Results: The subjects comprised 76 (76%) females and 24 males. Mean age was $41.8{\pm}SD$ 12.3 years. Sensitivity and specificity with 95%CI of ultrasound in differentiating malignant thyroid nodule from benign thyroid nodule calculated to be 91.7% (95%CI, 0.72-0.98) and 78.94% (0.68-0.87) respectively. Reported positive predictive value and negative PV were 57.9% (0.41-0.73) and 96.8% (0.88-0.99) and overall accuracy was 82%. Likelihood ratio (LR) positive was computed to be 4.3 and LR negative was 0.1. Conclusions: Ultrasonography has a high diagnostic accuracy in detecting malignancy in thyroid nodules on the basis of features like echogenicity, margins, micro calcifications and shape.

Factors Associated with Periductal Fibrosis Diagnosed by Ultrasonography Screening among a High Risk Population for Cholangiocarcinoma in Northeast Thailand

  • Intajarurnsan, Sutheera;Khuntikeo, Narong;Chamadol, Nittaya;Thinkhamrop, Bandit;Promthet, Supannee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4131-4136
    • /
    • 2016
  • Background: The population in northeast Thailand continues to present with hepatobiliary abnormalities, particularly periductal fibrosis (PDF) which is the result of chronic infection with liver fluke (Opisthorchis viverini; OV) and may lead to the development of cholangiocarcinoma (CCA). Although the prevalence of OV infection has been decreased due to a liver fluke control program over decades, the prevalence of PDF remains high. This study aimed to investigate demographic factors associated with PDF risk based on ultrasonography (US) screening. Materials and Methods: This cross-sectional study is part of the Cholangiocarcinoma Screening and Care Program (CASCAP), a prospective cohort study. Multiple logistic regression was used for data analysis. Results: In 55,246 subjects, the overall prevalence of PDF was 33.0% (95%CI: 32.6 - 33.4). Males (33.9 %) were at higher risk for developing PDF than females (32.2 %) (ORcrude = 0.93; 95%CI: 0.89 - 0.96; p-value < 0.001). Factors associated with an increased PDF risk, in addition to OV infection, included old age (${\geq}70$ years) (ORadj = 1.28, 95% CI: 1.14 - 1.44, p < 0.001) and hepatitis B infection (ORadj = 1.31, 95% CI: 1.11 - 1.55, p = 0.001). In contrast, number of praziquantel treatments (> 2 times) (ORadj = 0.54, 95% CI: 0.47 - 0.63, p < 0.001) and diabetes mellitus (ORadj = 0.57, 95% CI: 0.49 - 0.65, p < 0.001) were significantly associated with a decreased PDF risk. Conclusions: Future US screening should closely examine older people and hepatitis B subjects for the purpose of PDF surveillance among high risk groups for CCA. However, the results of inverse associations require further investigation in order to confirm our findings.

Reliability of Ultrasonography for The Longus Colli in Asymptomatic Subjects (건강한 성인의 경장근 두께 측정에 대한 초음파영상법의 신뢰도)

  • Lee, Jin-Ah;Kim, Suhn-Yeop
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.4
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: The objective of this study was to evaluate the inter- and intra-examiner reliability of ultrasonography (US) for measuring the thicknesses and cross-sectional area of the longus colli muscle (LCM) in healthy subjects. Methods: Twenty-five healthy adults participated in this study as subjects and two examiners attended to the study. LCM size was measured at the level of the thyroid cartilage. All subjects were randomly allocated to one of the three different methods. Method 1 was that the examiner A conducts the first measurement and one hour later conducts the second measurement and twenty four hours later conducts the third measurement, respectively. Method 2 was that the examiner B conducts the measurements in the same way as the examiner A. Method 3 was that the examiners A and B randomly conduct the measurements twice at an interval of one hour. Results: The intra-class correlation coefficient (ICC) for the intra-examiner reliability ranged from 0.78 to 0.98 at rest and 0.57 to 0.98 during contraction for the examiner A. The $ICC_{3,3}$ for the intra-examiner reliability ranged from 0.60 to 0.96 at rest and 0.57 to 0.92 during contraction for the examiner B. The $ICC_{2,3}$ for the inter-examiner reliability ranged from 0.80 to 0.91 at rest and 0.84 to 0.93 during contraction. Conclusion: The findings of this study indicate that US is a reliable method for measuring the LCM size.

Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria

  • Younghee Yim;Dong Gyu Na;Eun Ju Ha;Jung Hwan Baek;Jin Yong Sung;Ji-hoon Kim;Won-Jin Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.108-116
    • /
    • 2020
  • Objective: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies. Materials and Methods: A total of 2586 thyroid nodules (≥ 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated. Results: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1-100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8-83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7-19.8%, 0-40.9%, and 0.1-30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0-5.9%, 0-10.9%, and 0.1-8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0-33.8%), decreased with the simulated biopsy size criteria (0-8.7%). Conclusion: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies.

Sonographic Diagnosis of Cervical Lymph Node Metastasis in Patients with Thyroid Cancer and Comparison of European and Korean Guidelines for Stratifying the Risk of Malignant Lymph Node

  • Sae Rom Chung;Jung Hwan Baek;Yun Hwa Rho;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1102-1111
    • /
    • 2022
  • Objective: To evaluate the ultrasonography (US) features for diagnosing metastasis in cervical lymph nodes (LNs) in patients with thyroid cancer and compare the US classification of risk of LN metastasis between European and Korean guidelines. Materials and Methods: From January 2014 to December 2018, US-guided fine-needle aspiration was performed on 836 LNs from 714 patients for the preoperative nodal staging of thyroid cancer. The US features of LNs were retrospectively reviewed for the following features: size, presence of hilum, margin, orientation, cystic change, punctate echogenic foci (PEF), large echogenic foci, eccentric cortical thickening, abnormal vascularity, and cortical hyperechogenicity. A multiple logistic regression analysis was performed to identify the independent US features for the diagnosis of metastatic LNs. The diagnostic performance of independent US features was subsequently evaluated. LNs were categorized according to the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) and European Thyroid Association (ETA) guidelines, and the correlation between the two sets of classifications was assessed. Results: Absence of the hilum, presence of cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity were independent US features of metastatic LNs. Cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity showed high specificity (86.8%-99.6%). The absence of the hilum had the highest sensitivity yet low specificity (66.4%). When LNs were classified according to the ETA guidelines and K-TIRADS, they yielded similar categorizations of malignancy risks and were strongly correlated (Spearman coefficient, 0.9766 [95% confidence interval, 0.973-0.979]). According to the ETA guidelines, 9.8% (82/836) of LNs were classified as "not specified." Conclusion: Absence of hilum, cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity were independent US features suggestive of metastatic LNs in thyroid cancer. Both K-TIRADS and the ETA guidelines provided similar risk stratification for metastatic LNs with a high correlation; however, the ETA guidelines failed to classify 9.8% of LNs into a specific risk stratum. These results may provide a basis for revising LN classification in future guidelines.