• Title/Summary/Keyword: Ultrasonography (US)

Search Result 193, Processing Time 0.029 seconds

A Clinical Significance of Abdominal Ultrasonography (복부 초음파검사의 중요성)

  • Jeong, Gyu-Byeong
    • Journal of Korea Association of Health Promotion
    • /
    • v.3 no.1
    • /
    • pp.110-120
    • /
    • 2005
  • The ultrasonography(US) is one of very important item for abdominal evaluation. Especially for the routine check of the abdomen, the US becomes the essential part of the precedure. Though the abdominal US is simple and easy, its value is very high for detection of various morphological changes of abdominal organs. The study techniques of US, common abdominal abnormalities, standardization of image interpretation, and clinical significance of the lesions, etc, were discussed.

  • PDF

Abnormal Findings of the Ultrasonography for Elbow and Forearm (주관절과 전완부의 초음파 이상 소견)

  • Kim, Eunkuk
    • Clinical Pain
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Ultrasonography (US) of the elbow is an increasingly utilized modality for a variety of diagnoses. In this brief review, US findings for the pathologic conditions of forearm and elbow are described. The most common pathologies discussed here include distal biceps tendon and triceps tendon lesions, medial and lateral epicondylopathies, ulnar collateral ligament tears, ulnar nerve subluxation, joint effusions, and intra-articular bodies.

The pros and cons of ultrasound-guided procedures in pain medicine

  • Jee Youn Moon
    • The Korean Journal of Pain
    • /
    • v.37 no.3
    • /
    • pp.201-210
    • /
    • 2024
  • The application of ultrasound (US) in pain medicine has been a rapidly growing field since the 2000s. Musculoskeletal injections, peripheral nerve blocks, and neuraxial injections under US guidance have been acknowledged for managing chronic pain. Although many studies on US-guided pain procedures have been published, there needs to be a classification system to evaluate which image device, the US or fluoroscopy, is clinically and technically better in various pain interventions. Therefore, this narrative review introduces the classification system for the US-guided pain procedures according to their clinical and technical outcomes and designates US-guided pain procedures into one of the four categories by reviewing previous prospective randomized comparative trials.

Contrast-Enhanced Spectral Mammography Versus Ultrasonography: Diagnostic Performance in Symptomatic Patients with Dense Breasts

  • Zhongfei Lu;Cuijuan Hao;Yan Pan;Ning Mao;Xin Wang;Xundi Yin
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.442-449
    • /
    • 2020
  • Objective: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) versus ultrasonography (US) in symptomatic patients with dense breasts, while using histology as the gold standard. Materials and Methods: After obtaining approval from the local ethics board, this prospective study collected data from patients with symptomatic breasts who underwent CESM and US examinations from May 1, 2017 to September 30, 2017. We then selected those with dense breasts and pathological results as our sample population. Both CESM and US results were classified by a radiologist through the Breast Imaging Reporting and Data System, and the results were compared with their corresponding histological results. The chi-square test was conducted to compare the diagnostic performance of CESM and US, and the receiver operating characteristic curves for the two imaging modalities were obtained. Results: A total of 131 lesions from 115 patients with dense breasts were included in this study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 93.8%, 88.1%, 88.2%, 93.7%, and 90.8% for CESM, and 90.6%, 82.1%, 82.9%, 90.2%, and 86.3% for US, respectively. The p values for sensitivity, specificity, PPV, NPV, and accuracy were 0.687, 0.388, 0.370, 0.702, and 0.238, respectively. The area under the curve of CESM (0.917) was comparable with that of US (0.884); however, the differences between CESM and US were not statistically significant (p = 0.225). Eight false-positive cases and 4 false-negative cases for breast cancer were found in CESM, while 12 false-positive cases and 6 false-negative cases were found in US. Conclusion: The diagnostic performances of CESM and US are comparable in symptomatic women with dense breasts; however, the routine use of additional US imaging is questionable for lesions that can be detected by CESM.

The efficacy of ultrasonography in monitoring the healing of jaw lesions

  • Zainedeen, Obai;Haffar, Iyad Al;Kochaji, Nabil;Wassouf, George
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose: This study aimed to assess the reliability of ultrasonography (US) in comparison with cone-beam computed tomography (CBCT) as a tool for monitoring the healing of jaw lesions. Materials and Methods: Twenty-one radiolucent lesions in jaws referred to the Oral Surgery Department at our institution were selected for this study. All lesions underwent CBCT and US examinations. The anteroposterior, superoinferior, and mesiodistal dimensions of the lesions were measured on CBCT and US images before surgery and at 6 months after surgery. The dimensions were compared between the US and CBCT images. Blood-flow velocity around the lesions was measured by color Doppler before surgery and at 1 week and 6 months after surgery to assess the capability of US to show changes in blood-flow velocity around the lesion. Results: Before surgery, there were no significant differences between US and CBCT in the mesiodistal and anteroposterior dimensions, although a significant difference was found in the superoinferior dimension (P<.05). However, at 6 months after surgery, significant differences were found between US and CBCT in all dimensions, and it is likely that the US measurements more accurately reflected the extent of healing. The average blood-flow velocity increased at 1 week after surgery (5.84 cm/s) compared with the velocity before surgery (4 cm/s) (P<.05). Then, at 6 months after surgery, the blood-flow velocity significantly decreased (3.53 cm/s) compared to the velocity measured at 1 week after surgery (P<.05). Conclusion: US with color Doppler was confirmed to be a more efficient tool than CBCT for monitoring bone healing.

A Reproducible and Reliable Method for Measuring Masseter Muscle Thickness in Maximal Bite Force Using Ultrasonography

  • Hyun-Jeong Park;Sun-Kyoung Yu;Yo-Seob Seo;Ji-Won Ryu
    • Journal of Oral Medicine and Pain
    • /
    • v.47 no.4
    • /
    • pp.206-211
    • /
    • 2022
  • Purpose: The purpose of this study is to develop a reproducible and reliable method for evaluating the masseter's functional state by measuring the masseter muscle with ultrasonography (US). Methods: Nineteen healthy adults (9 males, 10 females) were the subjects of this study. During US scanning, the image was taken from the thickest part of the masseter muscle in the image. To evaluate changes in thickness during masseter function, US images were taken of the participant's masseter muscle at rest and during clenching. In this study, US scanning was conducted using two approaches to compare the difference in masseter muscle thickness determined when inducing maximum bite force (MBF). Results: All 19 subjects completed US scanning of the masseter muscle at rest and during clenching under the conventional method and the articulation paper method. There was no difference in masseter muscle thickness measured at rest. However, the thickness of the masseter muscles determined by the articulation paper during jaw clenching was greater than that measured by the conventional method. Conclusions: In conclusion, using the US for masseter muscle evaluation can offer objective and functional information on the masseter muscle. A standardized US scanning method needs to be developed to obtain reproducible and reliable information on the masseter muscle at rest and during clenching. In particular, generating MBF using an articulation paper can be a reproducible and reliable method of measuring the functional state of the masseter muscle.

Contrast-Enhanced CT and Ultrasonography Features of Intracholecystic Papillary Neoplasm with or without associated Invasive Carcinoma

  • Jae Hyun Kim;Jung Hoon Kim;Hyo-Jin Kang;Jae Seok Bae
    • Korean Journal of Radiology
    • /
    • v.24 no.1
    • /
    • pp.39-50
    • /
    • 2023
  • Objective: To assess the contrast-enhanced CT and ultrasonography (US) findings of intracholecystic papillary neoplasm (ICPN) and determine the imaging features predicting ICPN associated with invasive carcinoma (ICPN-IC). Materials and Methods: In this retrospective study, we enrolled 119 consecutive patients, including 60 male and 59 female, with a mean age ± standard deviation of 63.3 ± 12.1 years, who had pathologically confirmed ICPN (low-grade dysplasia [DP] = 34, high-grade DP = 35, IC = 50) and underwent preoperative CT or US. Two radiologists independently assessed the CT and US findings, focusing on wall and polypoid lesion characteristics. The likelihood of ICPN-IC was graded on a 5-point scale. Univariable and multivariable logistic regression analyses were performed to identify significant predictors of ICPN-IC separately for wall and polypoid lesion findings. The performances of CT and US in distinguishing ICPN-IC from ICPN with DP (ICPN-DP) was evaluated using the area under the receiver operating characteristic curve (AUC). Results: For wall characteristics, the maximum wall thickness (adjusted odds ratio [aOR] = 1.4; 95% confidence interval [CI]: 1.1-1.9) and mucosal discontinuity (aOR = 5.6; 95% CI: 1.3-23.4) on CT were independently associated with ICPN-IC. Among 119 ICPNs, 110 (92.4%) showed polypoid lesions. Regarding polypoid lesion findings, multiplicity (aOR = 4.0; 95% CI: 1.6-10.4), lesion base wall thickening (aOR = 6.0; 95% CI: 2.3-15.8) on CT, and polyp size (aOR = 1.1; 95% CI: 1.0-1.2) on US were independently associated with ICPN-IC. CT showed a higher diagnostic performance than US in predicting ICPN-IC (AUC = 0.793 vs. 0.676; p = 0.002). Conclusion: ICPN showed polypoid lesions and/or wall thickening on CT or US. A thick wall, multiplicity, presence of wall thickening in the polypoid lesion base, and large polyp size are imaging findings independently associated with invasive cancer and may be useful for differentiating ICPN-IC from ICPN-DP.

Significance of Follow-Up Ultrasonography 24 Hours Post-Reduction in Detecting Intussusception Recurrence

  • Kim, Sujin;Lim, HyeJi;Park, Sowon;Koh, Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.1
    • /
    • pp.21-29
    • /
    • 2022
  • Purpose: The objective of this study was to identify the significance of 24-hour post-reduction ultrasonography (US) in pediatric patients with intussusception. Methods: A total of 229 patients with intussusception who were treated with saline reduction at Severance Children's Hospital between January 2014 and September 2020 were retrospectively reviewed. The 229 patients with successful saline reduction were divided into two groups: a recurrence at 24 hours group (R, n=41) and a non-recurrence group (NR, n=188). The full patient sample was divided into two groups: follow-up US (FU) or no follow-up US (NFU); the recurrence group was divided into follow-up (R-FU) and non-follow-up (R-NFU) subgroups, and stratified analyses were performed. Results: There were no significant differences in age, sex, laboratory findings, symptoms, and sonographic findings between the NR and R groups. In the R group, 24 patients underwent follow-up US, and 17 patients did not. Specific sonographic findings were statistically significant in the R-FU group compared to the R-NFU group (p=0.002). The R-FU group had fewer admissions (p=0.012) and longer mean hospitalization times (p<0.001) than the R-NFU group. The NFU group had a 12.2% recurrence rate, while the R-FU group recurrence rate was 25.8% (p=0.0099), suggesting that the omission of some recurrent events and follow-up US was a significant variable in the recurrence of intussusception. The median time to recurrence was 21 hours which supports the 24-hour follow-up protocol. Conclusion: Twenty-four-hour follow-up US was shown to be valuable for detecting early recurrence of intussusception.

Using Ultrasonography Measurements to Determine the Depth of the GB 21 Acupoint to Prevent Pneumothorax

  • Chen, Hsiao-Neng;Chang, Chau-Yi;Chen, Lian-Zen;Chang, Yu-Jun;Lin, Jaung-Geng
    • Journal of Acupuncture & Meridian Studies
    • /
    • v.11 no.6
    • /
    • pp.355-360
    • /
    • 2018
  • Introductions: Pneumothorax is the most frequent severe acupuncture-related adverse event occurring at the GB 21 acupoint. This study used ultrasonography (US) to measure the depth of the GB 21 acupoint in adults and assessed its applicability for ensuring safe acupuncture practices. Materials and methods: A US probe was used to measure the vertical depth from the skin to the pleural line of the apex of the lungs at the right and left GB 21 acupoints. The sex, age, body weight, height, and body mass index of each person were recorded. Student t test and generalized estimating equations were used for statistical analysis. Results: Sixty women and 41 men with a median age of 29 years were included in this study. The depth of GB 21 increased with body weight, height, and body mass index (p < 0.001). The mean depth of GB 21 in men (17.4 mm) was greater than that in women (14.6 mm; p < 0.001). The depth difference between the right and left shoulders was significant in men (p < 0.001) but not in women. Conclusions: US can be used to measure GB 21 acupoint depth. Further control studies on its use to ensure safe clinical practices, including preventing acupuncture-related pneumothorax, are warranted.

The Effect of Mobilization Combined with Shoulder Active Contraction of Depth between the Coracoid Process and Humeral Head (어깨의 능동 수축을 동반한 관절가동술이 부리돌기와 위팔뼈 머리 사이의 거리에 미치는 영향)

  • Sun-min Kim;Sang-hun Jang
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.2
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: This study examined the distance between the coracoid process and the humeral head using an ultrasonography device when shoulder active contraction were applied according to the guided direction in the end range of shoulder mobilization. This study aims to provide essential data on treating shoulder disease patients. Methods: The subjects of this study were 20 adults with healthy shoulder joints. ultrasonography (US) equipment was used to examine shoulder joint mobilization under two conditions: (1) anteroposterior (AP) joint mobilization and (2) superoinferior (SI) joint mobilization. Shoulder active contraction was assessed in the end range. The distance between the coracoid process and the humeral head was measured. A linear probe was used for US; the frequency was set to 7.5MHz, and the US image display method was set to B-mode. The US measurement values were measured in (1) the starting position, (2) the end range position, and (3) the end range position of the shoulder active contraction, and the moving distance was drawn in a straight line through the US image. The distance was determined as the measurement value, and the average values were compared. Reults: The results were as follows: (1) the measured AP Joint mobilization increased by an average of .52cm from the end range of the joint mobilization with shoulder active contraction; (2) the measured SI Joint mobilization increased by an average of .49cm from the end range of the joint. Conclusion: When shoulder mobilization is applied, the distance between the coracoid process and the humeral head increases when muscle contraction occurs through shoulder active contraction in the end range, according to the therapist's guidance. Therefore, shoulder mobilization combined with shoulder active contraction is an effective treatment method for patients with shoulder injuries.

  • PDF