• Title/Summary/Keyword: Ultrasonographic evaluation

Search Result 98, Processing Time 0.021 seconds

Ultrasonographic Diagnosis in the Knee (슬관절에서의 초음파적 진단)

  • Min, Kyoung-Dae
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • Ultrasound is a first line examination of the knee and useful diagnostic tool in assessing the various knee lesions. The advantages of ultrasound are that it is non-invasive, easily available at bed side, cheap, well accepted by patients, and that it has technical benefits including dynamic evaluation. Its limitations include reliability, which is largely operator dependent and its inability to evaluate deep structures. Technical guidelines of the ultrasound released by European Society of MusculoSkeletal Radiology (ESSR) and ultrasonographic findings of various knee lesions are described.

  • PDF

Quantitative Evaluation of Median Nerve Motor Function in Carpal Tunnel Syndrome Using Load Cell : Correlation with Clinical, Electrodiagnostic, and Ultrasonographic Findings

  • Kim, Dong Hwan;Park, Sung Bae;Lee, Sang Hyung;Son, Young-Je;Chung, Gih Sung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.232-235
    • /
    • 2013
  • Objective : Major complaints of carpal tunnel syndrome (CTS) are sensory components. However, motor deficit also impedes functional status of hand. Contrary to evaluation of sensory function, the objective, quantitative evaluation of median nerve motor function is not easy. The motor function of median was evaluated quantitatively using load cell and its correlation with findings of electrodiagnostic study (EDS) was evaluated. Methods : Objective motor function of median nerve was evaluated by load cell and personal computer-based measurement system. All of the measurement was done in patients diagnosed as having idiopathic CTS by clinical features and EDS findings. The strength of thumb abduction and index finger flexion was measured in each hand three times, and the average value was used to calculate thumb index ratio (TIR). The correlation of TIR with clinical, EDS, and ultrasonographic findings were evaluated. Results : The TIR was evaluated in 67 patients (119 hands). There were 14 males and 53 females, mean age were 57.6 years (range 28 to 81). The higher preoperative nerve conductive studies grade of the patients, the lower TIR was observed [p<0.001, analysis of variance (ANOVA)]. TIR of cases with thenar atrophy were significantly lower than those without (p<0.001, t-test). TIR were significantly lower in patients with severe median nerve swelling in ultrasonography (p=0.042, ANOVA). Conclusion : Measurements of median nerve motor function using load cell is a valuable evaluation tool in CTS. It might be helpful in detecting subclinical motor dysfunction before muscle atrophy develops.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Evaluation of Normal Abdominal Organs by Diagnostic Imaging in the Premature Miniature Pig (미성숙 미니돼지에서 방사선과 초음파를 이용한 복부장기의 평가)

  • Chang, Jin-Hwa;Jung, Joo-Hyun;Oh, Sun-Kyoung;Choi, Min-Cheol
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.417-421
    • /
    • 2009
  • This report describes the normal radiographic and ultrasonographic morphological features of premature minipigs at 4, 8, 12 and 20 weeks of age. Radiographic examination is a simple diagnostic method used to identify the general morphologic state of major organs and their adjacent structures, and to assess the presence of abnormalities. The parameters for evaluation in plain abdominal radiographs are the degree of diffuse serosal margin details, extent of visualization of each organ, their size, shape, and contour, locations of main organs - such as the liver, stomach, spleen, kidneys, urinary bladder - the distribution of the intestines, and assessment of the retroperitoneal space and its contents. Ultrasonographic examinations are used to investigate their internal condition. The parameters for evaluation in abdominal ultrasonography are echogenicity, echotexture, and size and shape of the main organs such as the liver, spleen, kidney, urinary bladder and gastrointestinal tract. Minipigs had similar findings compared to dogs or cats.

Diagnostic Efficacy of Fine Needle Aspiration Cytology, Frozen section Biopsy and Ultrasonography for a Palpable Thyroid Mass (갑상선 촉지 종괴에서 시행한 세침흡인세포검사법, 동결절편검사법 및 초음파검사법의 진단적 유용성)

  • Lee Byoung-Kil;Jung Sung-Hoo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.18 no.2
    • /
    • pp.168-172
    • /
    • 2002
  • Objectives: This study was done to determine the diagnostic efficacy of fine needle aspiration cytology (FNA), frozen section biopsy (FSx) and ultrasonography in a palpable thyroid mass. Materials and Methods: During the period from July 1999 to March 2002, the medical records of 98 patients who underwent a thyroidectomy for thyroid mass, at the Department of Surgery, Chonbuk National University Hospital, were reviewed retrospectively. Ninety eight cases were classified according to whether the FNA cytological diagnosis inadequate, benign, suspicious, or malignant and the FSx diagnosis benign or malignant and the ultrasonographic examination was benign, suspicious, or malignant. The diagnostic correlations of ultrasonography, FNA cytology, frozen section, and both FNA cytology and frozen section with definite histologic diagnosis were evaluated. Results: According to the FNA cytological interpretation, 76 cases were diagnosed as benign, 6 cases suspicious, 13 cases malignant, and 3 cases inadequate. The sensitivity and specificity for FNA were 86.3% and 95.9% and for FSx 95.5% and 100% respectively. The diagnostic accuracy of FNA and FSx were 93.5% and 98.9% respectively. Based on a definite histologic diagnosis, the ultrasonographic examination had a sensitivity and a specificity of 77.2% and 78.9%. Conclusion: The results confirm that FNA cytology is a reliable and useful tool in the initial evaluation of a palpable thyroid mass compared to the ultrasonographic examination. Intraoperative FSx is a valuable diagnostic procedure to confirm the cytological diagnosis with undetermined or unsatisfactory cytological diagnosis.

Value of Ultrasonography in the Diagnosis of Carpal Tunnel Syndrome : Correlation with Electrophysiological Abnormalities and Clinical Severity

  • Kim, Min-Kyu;Jeon, Hong-Jun;Park, Se-Hyuck;Park, Dong-Sik;Nam, Hee-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.78-82
    • /
    • 2014
  • Objective : To investigate a diagnostic value of ultrasonography in carpal tunnel syndrome (CTS) patients and to evaluate a correlation of sonographic measurements with the degree of electrodiagnostic abnormalities and clinical severity. Methods : Two-hundred-forty-six symptomatic hands in 135 patients and 30 asymptomatic hands in 19 healthy individuals as control group were included. In ultrasonographic study, we measured the cross-sectional area (CSA) and flattening ratio (FR) of the median nerve at the pisiform as well as palmar bowing (PB) of the flexor retinaculum. Sensitivity and specificity of ultrasonographic measurements were evaluated and ultrasonographic data from the symptomatic and control hands were compared to the grade of electrodiagnostic and clinical severity. Results : The mean CSA was $13.7{\pm}4.2mm^2$ in symptomatic hands and $7.9{\pm}1.3mm^2$ in asymptomatic hands. The mean FR was $4.2{\pm}1.0$ in symptomatic hands and $3.4{\pm}0.4$ in asymptomatic hands. The mean PB was $3.5{\pm}0.5$ mm in symptomatic hands and $2.6{\pm}0.3$ mm in asymptomatic hands. Statistical analysis showed differences of the mean CSA, FR and PB between groups were significant. A cut-off value of $10mm^2$ for the mean CSA was found to be the upper limit for normal value. Both the mean CSA and PB are correlated with the grade of electrophysiological abnormalities and clinical severity, respectively. Conclusion : Ultrasographic measurement of the CSA and PB is helpful to diagnose CTS as a non-invasive and an alternative modality for the evaluation of CTS. In addition, ultrasonography also provides a reliable correlation with the grade of electrodiagnostic abnormalities and clinical severity.

Ultrasonographic Indeterminate Lymph Nodes in Preoperative Thyroid Cancer Patients: Malignancy Risk and Ultrasonographic Findings Predictive of Malignancy

  • Roh-Eul Yoo;Ji-hoon Kim;Jeong Mo Bae;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Seung Hong Choi;Chul-Ho Sohn;Jung Hyo Rhim;Sun-Won Park
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.598-604
    • /
    • 2020
  • Objective: Proper management of lymph nodes (LNs) with ultrasonographic (US) indeterminate features in thyroid cancer patients remains elusive. We aimed to evaluate the malignancy risk and US findings predictive of malignancy for US indeterminate LNs in preoperative thyroid cancer patients through node-by-node correlation. Materials and Methods: A total of 348 LNs in 284 thyroid cancer patients, who underwent fine-needle aspiration or core-needle biopsy between December 2006 and June 2015, were included. We determined the malignancy risks for US probably benign, indeterminate, and suspicious categories. For US indeterminate LNs, which had neither echogenic hilum nor hilar vascularity in the absence of any suspicious finding, US findings were compared between benign and metastatic LNs using Mann-Whitney U test and Fisher's exact test. Results: US imaging diagnoses were probably benign in 20.7% (n = 72) cases, indeterminate in 23.6% (n = 82), and suspicious in 55.7% (n = 194). Malignancy risk of US indeterminate LNs (19.5% [16/82]) differed from those of the US probably benign (2.8% [2/72]) (p = 0.002) and US suspicious LNs (78.4% [152/194]) (p < 0.001). Among US indeterminate LNs, there were no significant differences in short, long, and long-to-short diameter (L/S) ratios between benign and metastatic LNs (3.9 vs. 3.8 mm, p = 0.619; 7.3 vs. 7.3 mm, p = 0.590; 1.9 vs. 1.9, p = 0.652). Conclusion: US indeterminate LNs were frequently encountered during preoperative evaluation and had intermediate malignancy risk. Given the lack of discriminative power of size criteria and L/S ratio, clinical factors such as surgical strategy and node size should be considered for proper triage of US indeterminate LNs in thyroid cancer.

Ultrasonographic evaluation of common compression neuropathies in the upper limb

  • Seok, Jung Im
    • Annals of Clinical Neurophysiology
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Neuromuscular ultrasonography has emerged over the last decade as a useful tool for diagnosing peripheral nerve disorders. It has been studied extensively with a particular focus on the assessment of compression neuropathies. Neuromuscular ultrasonography complements electrodiagnostic studies well by visualizing both the nerve anatomy and surrounding structures, providing useful data that cannot be obtained using the latter methodology only. This review article summarizes and synthesizes the literature focusing on the diagnostic role of neuromuscular ultrasonography in common compression neuropathies of the upper limb.

Ultrasonographic Resistive Index of the Interlobar Renal Artery in Renal Failure Induced by Ochratoxin A and Citrinin Toxicosis in Dogs (Ochratoxin-A 및 Citrinin 중독 신부전 개에서 신장엽간동맥 혈관저항지수에 대한 도플러초음파 평가)

  • Bae, Jun-Woo;Seong, Yun-Sang;Oh, Tae-Ho;Jang, Kwang-Ho;Lee, Keun-Woo;Eom, Ki-Dong
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.427-431
    • /
    • 2006
  • Pulse Doppler ultrasonographic evaluation was performed to investigate the resistive index (RI) of the Interlobar renal artery in 17 dogs (32 kidneys) which were diagnosed with an acute renal failure caused by ochratoxin-A and citrinin contaminated commercial diet. RI was investigated in 7 normal beagle dogs and recovered patients. The mean of RI was resulted as $0.69{\pm}0.04$ in normal dog, however, significantly (p<0.001) increased as $0.76{\pm}0.05$ in renal failure dog. But RI had no relationship with the results of blood chemistry, urine analysis, and excretory urographic image quality. From these results, even though the results of the renal function test were within a normal reference range, it was considered that RI index is more reliable to represent a damaged renal parenchyma, and may have the potential to be a useful clinical tool in monitoring of the renal function.

Ultrasonographic assessment of transitional cell carcinoma of the urinary bladder in dogs: a perspective of tumor size change

  • Kim, Seungji;Kim, Yongbaek;Kim, Wanhee;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.57 no.3
    • /
    • pp.205-208
    • /
    • 2017
  • Study purposes were to evaluate ultrasonographic characteristics of transitional cell carcinoma (TCC) and quantitate bladder tumor size in dogs. Heterogeneous mass, wall involvement, and broad-based attachment were significantly associated with TCC, but not prominently the trigone region. Mass size evaluation revealed a significant correlation between progressive disease (PD) in TCC patients with piroxicam therapy. Largest diameter of target lesion/body weight (cm/kg) ratio showed a high mean value in PD. A value > 0.3 was associated with PD with 83% sensitivity and 66% specificity. The results suggest that ultrasonography can provide evidence for diagnosing and predicting a prognosis for TCC.