• 제목/요약/키워드: Ultrasonic tip

검색결과 111건 처리시간 0.025초

굴곡 진동모드를 이용한 초음파 선형 압전 액추에이터 개발 (Development of ultrasonic linear piezoelectric actuator with flexuralvibration mode)

  • 윤장호;최우천;강종윤;강진규;윤석진
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.461-466
    • /
    • 2009
  • This paper represents a piezoelectric ultrasonic linear actuator with flexural vibration mode. The actuator is composed of two piezo ceramics, the elastic body, and the connecting tip. It is driven by the frictional force between the connecting tip and the linear motion guide. Unimorph actuators have flexural vibration. Its middle point is fixed so that suitable to the flexural vibration of $3/2\lambda$. These vibrations contribute to elliptical motion by mixed mode between longitudinal and transverse mode. It was generated when the ultrasonic electrical signals with 90 degree phase difference are applied to two ceramics. A linear movement can be easily obtained using the elliptical motion. The ATILA, FEM simulator has been used to design actuator and verify the kinetic and dynamic analysis. We used the ceramics of $20\times10\times1$ mm size and confirmed the flexural vibration of the $3/2\lambda$ at the 79 kHz through the scanning of 3D-vibrometer. The maximum velocity of actuator was 221 mm/sec and the thrust force of actuator was 2.7 N in 200Vp-p of additional voltage.

UAFM(초음파원자현미경) 팁의 진동-접촉 해석과 나노 표면에의 응용 (Vibro-Contact Analysis of Ultrasonic Atomic Force Microscopy Tip and It's Application to Nano Surface)

  • 박태성;곽동열;박익근;김정석
    • 비파괴검사학회지
    • /
    • 제30권2호
    • /
    • pp.132-138
    • /
    • 2010
  • 본 연구에서는 접촉역학 특성에 의한 캔틸레버 탑의 접촉-진동을 연구하고 나노스케일의 표면에서 탄성특성을 이미지화 하였다. 스프링-질량 모텔과 Herzian 이론을 이용하여 접촉공진주파수를 이론적으로 계산하고 초음파원자현미경을 이용하여 캔틸레버의 자유공진주파수와 접촉공진주파수의 변화를 분석하였다. 또한, 프로토타입의 초음파원자현미경을 이용하여 구상화 열처리된 시험편의 탄성 이미지를 위상과 진폭 신호를 이용하여 성공적으로 얻을 수 었었다.

치과 임플란트 수술용 고출력 초음파 수술기 설계 및 제작 (Design and Fabrication of a High Power Piezoelectric Ultrasonic Surgery Unit for Dental Implantation)

  • 김나리;전대우;김진호;김선욱;황종희;이정배;최성재;임대진;이영진
    • 한국전기전자재료학회논문지
    • /
    • 제30권10호
    • /
    • pp.656-664
    • /
    • 2017
  • This paper presents the design and fabrication of a high power piezoelectric ultrasonic surgery unit for multi-purpose dental implantation. A conventional piezoelectric ultrasonic surgery units consists of a transducer and a tip. However, the drawback of this simple structure is that the output performance of the transducer considerably changes with the change of the tips. An ultrasonic surgery unit that has an additional booster between the transducer and the tip can solve this problem to some extent; for this, an optimal structural design for the transducer is required. We used the Bolted Langevin Transducer (BLT) as the basic transducer; it consists of piezoelectric ceramics and a metal body. It's structure was optimized using mathematical methods to determine the length and radius of the tail and head masses. Additionally, the booster was also subjected to the same methods. Using these mathematical methods, optimal results in terms of the resonance frequency (24.96 kHz), displacement ($14.27{\mu}m$), and pressure (2.8 MPa), could be obtained. The validity of this proposed surgery unit was confirmed experimentally, exhibiting a cutting force of around 7% higher than that of a conventional surgery unit.

분말사출성형을 이용한 치과용 스케일러 팁 금형 및 성형기술개발 (Development of Dental Scaler Tip Mold and it's Molding Technology using Powder Injection Molding)

  • 고영배;김종선;정성택;황철진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.83-84
    • /
    • 2006
  • Due to the capability of net shaping for complex 3D geometry, powder injection molding (PIM) is widely used for automotive parts, electronics and medical industry. In this study, an ultrasonic dental scaler tip produced by machining process was redesigned for the PIM process. An injection mold was designed and manufactured to produce the dental scaler tip by the PIM process.

  • PDF

Development of Dental Scaler Tip Mold with Powder Injection Molding Process

  • Hwang, C.J.;Ko, Y.B.;Park, H.P.;Chung, S.T.;Rhee, B.O.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.499-500
    • /
    • 2006
  • With the capability of net shaping for complex 3D geometry, powder injection molding (PIM) is widely used for automotive parts, electronics and medical industry. In this study, an ultrasonic dental scaler tip produced by machining process was redesigned for the PIM process. An injection mold was designed and machined to produce the dental scaler tip by the PIM process.

  • PDF

LED 공정의 균일 코팅을 위한 초음파 진동자 설계 및 해석 (Design and Analysis of Ultrasonic Vibrator for Conformal Coating in LED Packaging)

  • 손병호;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.631-636
    • /
    • 2009
  • This paper presents design and analysis of ultrasonic vibrator featuring the piezoelectric actuator. After describing a geometric configuration of the proposed vibrator, an analytical model of the ultrasonic vibrator is formulated by adopting liquid film pattern theory and wave theory. The dynamic analysis and geometric optimization are then undertaken using a software ANSYS. The optimization is performed by taking the amplitude of the tip displacement as an objective function. The fluid flow characteristics of the proposed vibrator are analyzed by taking three different fluids: water, silicon oil and ethylene-glycol. This is achieved using a software FLUENT.

  • PDF

초음파회절방법(超音波回折方法)을 이용한 귀렬(龜裂)의 높이 측정(測定) (Measurement of the Crack Height using the Two-Probe Ultrasonic Diffraction Method.)

  • 이재옥;이승규;김영길
    • 비파괴검사학회지
    • /
    • 제7권2호
    • /
    • pp.35-41
    • /
    • 1988
  • The optimum test conditions of measuring the crack height were determined for the two-probe ultrasonic diffraction method. The applicability and the accuracy of the two-probe ultrasonic diffraction method on the inclined artificial cracks and the fatigue cracks were evaluated. It us possible to measure the height of the normal and inclined artificial cracks with the maximum error of ${\pm}\;0.5mm$ with the two-probe ultrasonic diffraction method. It was found, however, that the accuracy of this method in meaasuring the height of the fatigue crack depends on the degree of closure of the crack tip. It was desirable to choose a refraction angle as small as possible, but the angle should not be so small that the distortion of the lateral waveform became appreciable.

  • PDF

초음파 금속 용착을 위한 반파장 혼의 설계 및 제작 (A Horn of Half-wave Design and Manufacture for Ultrasonic Metal Welding)

  • 김은미;장호수;박동삼
    • 한국생산제조학회지
    • /
    • 제19권6호
    • /
    • pp.790-796
    • /
    • 2010
  • This paper designed the horn of half-wave needed for Ultrasonic meta) welding. The horn has to be designed and manufactured accurately, because measurements such as the shape, length, mass and etc. have effects on the resonant frequency and the vibration mode. Designed horn of half-wave has the feature of 40,000Hz of nature frequency, and maximizes vibration range in the Tip by resonance in the frequency of ultrasonic wave machine. In this study, we calculated and analyzed the natural frequency to find the optimal design of the horn that amplified the amplitude about double by the modal analysis and harmonic analysis using ANSYS. And we did FFT analysis of the manufactured horn.

LED 공정의 균일 코팅을 위한 초음파 진동자 설계 및 해석 (Design and Analysis of Ultrasonic Vibrator for Conformal Coating in LED Packaging)

  • 손병호;최승복
    • 한국소음진동공학회논문집
    • /
    • 제19권12호
    • /
    • pp.1289-1295
    • /
    • 2009
  • This paper presents design and analysis of ultrasonic vibrator featuring the piezoelectric actuator. After describing a geometric configuration of the proposed vibrator, an analytical model of the ultrasonic vibrator is formulated by adopting liquid film pattern theory and wave theory. The dynamic analysis and geometric optimization are then undertaken using a software ANSYS. The optimization is performed by taking the amplitude of the tip displacement as an objective function. The fluid flow characteristics of the proposed vibrator are analyzed by taking three different fluids: water, silicon oil and ethylene-glycol. This is achieved using a software FLUENT.

초음파를 이용한 콘크리트 시편의 피복두께 이하에 위치한 균열깊이 탐사 (Measurement of Crack Depth Located under Steel Reinforcement in Reinforced Concrete Specimens using Ultrasonic Method)

  • 임홍철;김연수;우상균;송영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.181-188
    • /
    • 2002
  • The objective of this study is to determine crack depth located under steel reinforcement in concrete specimens using ultrasonic method. Experimental studies were performed on concrete specimens containing vertical and inclined surface-opening cracks with known depths. The other studies were carried out on specimens with flexural crack. Experimental results have shown that the crack depth is effectually measured when the distance between the probes is less than the crack depth. The effect of steel on crack depth estimation is studied through a model by considering P-waves diffaction at the tip of crack and steel. In addition, experimental results show that the ultrasonic method is one of useful methods to evaluate the crack depth in reinforced concrete.