• 제목/요약/키워드: Ultrasonic diagnosis

검색결과 211건 처리시간 0.026초

Clinical Features and Survival Analysis of Very Young (Age<35) Breast Cancer Patients

  • Wei, Xue-Qing;Li, Xing;Xin, Xiao-Jie;Tong, Zhong-Sheng;Zhang, Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권10호
    • /
    • pp.5949-5952
    • /
    • 2013
  • Objectives: To compare the clinicalpathological features and prognosis between premenopausal breast cancer patients aged of <35 and ${\geq}35$ years old. Methods: The clinical data and survival status of 1498 cases premenopausal operable breast cancer treated in our hospital from 2002.1 to 2004. 12 were collected, 118 cases were aged <35. They were divided into 4 groups: Luminal A, Luminal B, HER2-positive, Triple-negative. The disease free survival (DFS) and overall survival (OS) were identified. Results: The 5-year DFS and OS rates were significantly lower in age<35 than in $age{\geq}35$ patients. In the Luminal B, HER2-positive, Triple-negative group, the 5-year recurrence risk was higher in age<35 than in $age{\geq}35$ patients, and age<35 patients' 5-year death risk was higher only in Luminal B, Triple-negative group. Regardless of whether lymph node involved, age<35 patients had a bad prognosis in both DFS and OS. Conclusions: Compared with premenopausal age ${\geq}35$ breast cancer, age<35 patients had a worse outcome.

超音波 信號 數의 移動平均에 의한 電力用 變壓器 豫防診 (Preventive diagnosis of the power transformer by the moving average of ultrasonic signal number)

  • 권동진;곽희로;정상진;김정부
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.432-437
    • /
    • 1996
  • This paper describes a diagnostic technique of power transformers by on-line detection of ultrasonic signals. A trend of partial discharge variation in a real transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is punctured. The number of electrical signals is closely related to the ultrasonic signals generated by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based on the trend analysis of ultrasonic signal number caused by partial discharge. (author). 14 refs., 10 figs.

  • PDF

초음파 측정기법을 사용한 케이블 접속부 예방진단 연구 (A Study on the Predictive Diagnosis of the Cable Joint Using Ultrasonic Technique)

  • 곽희로;이동준;박동화
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.78-84
    • /
    • 2000
  • 본 논문에서는 케이블 첩속부 내부 계면얘서 발생하는 부분방전에 의한 초음파 선호를 계측, 분석함으로써 예방진단기법을 제시하고자 한다, 초음파 선호의 분석 방법으로는 wavelet transfonn으로 필터링 하여 얻은 주요 특성 선호만올 Fast Fourier Transform (FFT)로 분석하였다. 그 결과 계면에 수분과 금속가루 존재시 그리고 인가 전압이 높아짐에 따라 서로 다른 특성을 얻을 수 있었다.

  • PDF

초음파 Doppler법에 의한 비침투적인 생체조직의 진동속도 계측 (In Vivo Doppler-Based Measurement of Bending Vibration Velocity in Liver Vibrated by Lo7v Frequency Signal)

  • 박무훈;장윤석
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.407-412
    • /
    • 1997
  • In this paper, we present a new method to diagnose the characteristics of the soft tissue, especially a liver. In order to diagnose the characteristics of a liver, it is necessary to evaluate the propagation delay time and propagation velocity of bending vibration In a liver. For this purpose, we measure the propagation velocity of bending vibration in a liver for low frequency forced vibration using a standard ultrasonic Doppler diagnosis equipment. We have carried out preliminary experiments by using an ultrasonic probe of 3.5MHz and obtained some results. This new measurement method developed here can be applied to new research and medical fields for acoustic non-invasive diagnosis of soft tissue.

  • PDF

절연진단용 광섬유 센서의 초음파 검출특성 (Ultrasonic-detection characteristics of optical-fiber sensor for insulation diagnosis)

  • 이상훈;심승환;이광식;김달우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.183-186
    • /
    • 2002
  • It is well known that a discharge in oil is the source of various physical and chemical phenomena. One of them is ultra-sonic wave, and its detection is a useful method to the diagnosis of the transformer insulation condition. Conventionally, ultra-sonic waves are detected by Piezo-electric trans-ducer(PZT), and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test of the ultrasonic-detecting ability was performed for both of PZT and fiber-optic sensor. Discharge test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and showed time-delay characteristics. We analyzed the data with frequency domain and wavelet transform.

  • PDF

고압권선에서 발생하는 부분방전에 의한 초음파 신호 검출 (Detection of Ultrasonic Signals by PD at the High Voltage Winding)

  • 권동진;곽희로;정상진;김한상;송일근;김경화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.456-458
    • /
    • 1995
  • This paper describes a diagnosis of power transformers by on-line detection of ultrasonic signals. Partial discharge in power transformer generates ultrasonic signals. The trend of the ultrasonic signal number can be measured when partial discharge is generated in HV Winding. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based in the trend analysis of the number of ultrasonic signals caused by partial discharge.

  • PDF

배전용 전력 케이블 접속재의 내부고장 검출에 관한 기초연구 (A Basic Study on Detection of Internal Defects in Distribution Cable Splices)

  • 박치영;진상범;곽희로;김상준;송일근;권동진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.122-124
    • /
    • 1996
  • This paper describes a diagnosis of distribution cable splices by analysis of ultrasonic signals which are generated by partial discharge. A method of ultrasonic signal was used to detect internal defects in distribution cable splices. It is possible that analysis of ultrasonic signal predicts failure by partial discharge generated in distribution cable splices.

  • PDF

개선된 초음파방법에 의한 변압기내 부분방전 위치 검출 (Improved Ultrasonic Method for Locating Partial Discharges in Transformers)

  • 곽희로;김재철;조국희;한민구;임주일;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.252-257
    • /
    • 1988
  • This paper discribes an improved technique for locating partial discharge sites within operating transformers by ultrasonic method which utilizes the different travel times of the electrical and ultrasonic signals produced by partial discharges to determine the location of the sources. The technique was to develope the measurement system based on the enhancement of the acoustic emission signals using signal square, circuit to improve the detectable sensitivity and reliability. Also an ultrasonic pulse generator was designed and made to transmit periodically pulses equivalent to pratial discharges and to check the good performance of the system, echo effects and self-diagnosis. Through the laboratory work, it was confirmed that the system and the generator can be used satisfactorily for diagnosing power transformers and for studying echo effects and self-diagnosis of the system.

  • PDF

초음파를 이용한 골다공증 진단 (Ultrasonic Diagnosis of Osteoporosis)

  • 이강일;윤석왕
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권2E호
    • /
    • pp.64-72
    • /
    • 2010
  • Osteoporosis is a skeletal disease characterized by two factors: reduced bone mass and microstructure disruption of bone tissue. These symptoms increase bone fragility and can contribute to eventual fracture. In recent years, quantitative ultrasound (QUS) technologies have played a growing role in the diagnosis of osteoporosis. Most of the commercial bone sonometers measure speed of sound and/or broadband ultrasound attenuation at peripheral skeletal sites. However, QUS parameters are purely empirical measures that have not yet been firmly linked to physical parameters, such as bone strength or porosity, and the underlying physics for their variations in cancellous bone is not well understood yet. This paper reviews the QUS technologies for the diagnosis of osteoporosis and also addresses several theoretical models, such as the Biot model, the scattering model, the stratified model, and the modified Biot-Attenborough model, for ultrasonic wave propagation in bone.

원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구 (A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants)

  • 김경조;강석철;구철수;김진호;박재석;주금종;박치승
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.325-330
    • /
    • 2004
  • 원자력발전소에는 여러 종류의 케이블이 전력공급, 감시 및 제어신호의 전달을 위해 열악한 환경하에서 이용되고 있다. 발전소의 안전한 운전을 위해서 이 케이블이 어느 정도 열화 되었는지 확인할 필요가 있다. 특히, 원자력발전소의 수명 연장과 더불어 저압 케이블을 장기간 사용함에 따라서 저압케이블의 열화를 평가하기 위한 방법이 필요하게 되었다 저압케이블의 열화를 측정하는 파라미터로는 주변 온도, 절연재질의 경도, 파단시 연신률(EAB, Elongation At Breaking Point) 등이 있다. 그러나, 온도나 경도를 계측하는 검사는 정량적인 판단기준의 설정이 곤란하고 진단의 정밀도가 낮으며, 부분적으로 샘플링하는 방법은 샘플링되는 케이블에 연결된 부하를 정전시켜야 하고 장소와 시간적인 제약이 있으며, 전기적 측정법은 노화 초기부터 중기까지의 열화정도를 확인하기 어렵다. 본 연구에서는 재료의 열화에 따라서 초음파의 음속이 변화한다는 이론적인 배경(1,2)을 바탕으로 저압 케이블 재료의 열화에 따른 초음파의 음속을 측정하였다. 이를 위해, 원자력발전소에서 사용되는 저압케이블을 가속 열화시켰으며, 저압케이블의 피복재에서 초음파의 음속을 측정할 수 있는 장비를 개발하여, 초음파의 음속측정 후 인장시험을 통해 파단시 연신률을 측정하였다. 파단시 연신률이 증가함에 따라서 음속이 선형적으로 감소하였으며, 초음파의 음속은 열화의 정량적 평가 파라미터로서의 사용 가능성을 확인할 수 있었다.