• Title/Summary/Keyword: Ultrasonic Signal

Search Result 638, Processing Time 0.023 seconds

A Study on the Detection of Ultrasonic Signal for the Diagnosis of Transformer (변압기 예방진단을 위한 초음파 신호 검출에 관한 연구)

  • 권동진;광희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.65-70
    • /
    • 1995
  • This paper describes the detection of the ultrasonic signals reduced by materials of a transformer for diagnosis of the transformer using ultrasonic signal which is generated by partial discharge. When partial discharge is generated on the surface of the winding and between the winding and the core in the transformer, the ultrasonic signal can be measured as the proper selection of the ultrasonic detectors' location.

  • PDF

A Study on the Enhancement of Ultrasonic Signal Recognition in Ferrite Carbon Steel Weld Zone Using Neural Networks (신경회로망을 이용한 페라이트계 탄소강 용접부의 초음파 신호 인식 향상에 관한 연구)

  • Yun, In-Sik;Park, Won-Kyou;Yi, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.158-164
    • /
    • 2002
  • This paper proposes the optimization of ultrasonic signal recognition in ferrite carbon steel weld zone using neural networks. For these purposes, the ultrasonic signals for defects as porosity, incomplete penetration and slag inclusion in the weld zone are acquired in the type of time series data. And then their applications evaluated feature extraction based on the time-frequency-attractor domain(peak to peak, rise time, rise slope, fall time, fall slope, pulse duration, power spectrum, and bandwidth) and attractor characteristics (fractal dimension and attractor quadrant) etc. The proposed neural networks system in this study can enhances performance of ultrasonic signal recognition.

Ultrasonic Distance Measurement Method by Using the Envelope Model of Received Signal Based on System Dynamic Model of Ultrasonic Transducers

  • Choe, Jin-Hee;Lee, Kook-Sun;Choy, Ick;Cho, Whang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.981-988
    • /
    • 2018
  • In order to acquire an accurate TOF, this paper proposes a method that produces TOF by using a mathematical model for the envelope of the received signal obtained from a system dynamic model of ultrasonic transducer. The proposed method estimates the arrival time of the received signal retrospectively by comparing its wave form obtained after triggering point with its mathematical envelope model. Experimental result shows that the error due to variation of triggering point can be dramatically decreased by implementing the proposed method.

Determination Method of O.T. Aging Level by Model Partial Discharge Test (모의 부분방전 시험에 의한 O.T. 절연열화 판정기준 설정 방안)

  • 진상범;권동진;곽회로;정용기;조국희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.85-95
    • /
    • 1995
  • This paper describes a diagnosis of transformer by ultrasonic signal due to partial discharge. The ultrasonic signal can be measured when partial discharge is generated in a real transformer. The trend of partial discharge in transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is destroyed. The number of ultrasonic signals is closely related to the number of the electrical signals by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average.

  • PDF

Assessment of Bearing Damage by Ultrasonic Measurement (초음파 측정에 의한 베어링손상 평가)

  • LEE SANG-GUK;LEE In-CHEOL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.395-400
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established. Bearing diagnosis system is composed of four parts as follows : sensing part for ultrasonic sensor and preamplifier, signal processing part for measuring frequency spectrum, energy and amplitude, interface part for connecting ultrasonic signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

  • PDF

A Study on the Wet Type Ultrasonic Flow-meter System Development (습식방식의 초음파 유량계 시스템 개발에 관한 연구)

  • Lee Eung-Suk;Kwon Oh-Hoon;Rho Myung-Hwan;Lee Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

Ultrasonic Signal Characteristics of Corona Discharges in Air (공기중 코로나방전의 초음파신호 특성)

  • Lee, Sang-Woo;Kim, In-Sik;Lee, Kwang-Sik;Lee, Dong-In;Lee, Dong-Heoon;Bae, Sang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1702-1704
    • /
    • 1998
  • In order to establish the usefulness of ultrasonic techniques for detecting corona discharges in high-voltage power apparatus, it is first necessary to determine the relationship between electrical and ultrasonic signals of corona discharges in air. In this paper, various characteristics of ultrasonic signal detection for point-to-plane corona discharges using a 200[kHz] ultrasonic sensor are examined. In regard to the attenuation and directivity of ultrasonic signals, the signals were inversely proportional to the distance between corona sources and ultrasonic receiving sensors, and half attenuation angles were approximately 7.0 degree. Ultrasonic signals of positive polarities were first obserbed at corona inception voltages. and the signals were increased with increasing the applied voltages.

  • PDF

A Study on the Measurement of Foreign Material in Dissimilar Metal Contact Using Pulse Laser and Confocal Fabry-Perot Interferometer (펄스 레이저와 CFPI를 이용한 이종금속 접촉부의 이물질 측정에 관한 연구)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.160-164
    • /
    • 2013
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasonics by using laser beam. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this study, galvanic corrosion phenomenon was measured by non-destructive and non-contact method using the laser. The case of mixed foreign material on the part of corrosion was assumed and laser ultrasonic experiment was conducted. Ultrasonic was generated by pulse laser from the back side of the specimen and ultrasonic signal was acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer(CFPI). The characteristic of the ultrasonic signal of exist foreign material part was analyzed and the location and size of foreign material was measured.

Signal-to-noise ratio enhancement of ultrasonic signal by using constant frequency-to-bandwidth ratio decomposition method (비대역폭 분할 방법을 이용한 초음파 신호의 S/N 비 개선)

  • 김태현;구길모;고대식;전계석
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.5
    • /
    • pp.50-57
    • /
    • 1994
  • In the non-destructive evaluation techniques using ultrasonic signal, backscattering noise from grain interface decreases the SNR of received signal. In this paper, SSP(split-spectrum processing) based on the constant FBR decomposition method has been applied to enhance the SNR. This algorithm helps to find optimal parameters of filter bank through a simple theory and has an advantage that reduce the signal processing time compared with the conventional constant bandwidth decomposition method. In this experiment, the 304 stainless steel sample is heat-treated and received ultrasonic signal is processed by SSP using the constand bandwidth decomposition method and the constand FBR decomposition method enhanced the SNR by 1.4 dB and reduced the required number of filters by 4 compared with the constant bandwidth decomposition method.

  • PDF

A Study on the Improvement in Performance of Ultrasonic Pulsed Doppler Velocimeter (초음파 펄스 도플러 속도계의 성능 개선에 관한 연구)

  • 이은방;이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.3
    • /
    • pp.85-95
    • /
    • 1996
  • In the velocimeter, the ultrasonic pulse signal is used for measuring the profile velocity of moving targets distributed in space because of the merits of its high distance resolution and harmless affect to the human body. The velocity reading in conventional ultrasonic pulsed velocimeter depends on the wave pattern reflecting the spatial distribution of scatters and includes observational error due to the signal processing of analyzing pulse signal. In this paper, we evaluate an influence of the received waveform of pulsed signal on the velocity information by setting a model. Subsequently, in order to improve the distance resolution and to obtain precise velocity information without the influence of the spatial distribution of scatterers, we propose a new method for the analysis of Doppler pulsed signal, in which the pulsed signal is transformed into a phase function with local data. Finally, it is confirmed that the performance of the velocimeter is more improved in the proposed method than in the conventional one.