• Title/Summary/Keyword: Ultrasonic Power

Search Result 670, Processing Time 0.025 seconds

Precision Measurement of Ultrasonic Power the Milliwatt Range (밀리와트 영역의 초음파 파워 정밀 측정)

  • Jho, Moon-Jae;Hwang, Cheol-Ho;Suh, Sang-Joon;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.25-33
    • /
    • 1990
  • An ultrasonic power measurement system in milliwatt range was constructed. The ultrasonic power can be determined by measuring the radiation pressure on a target using self-compensating microbalance. Measurement was performed using a perfect reflector and a perfect absorber. In order to check the feasibility of the system, the ultrasonic power for the two targets was measured. Also, the systematic measurement errors and the reproducibility were examined. The relative error between two targets is proved to be within 2%. Also when the ultrasonic power range is larger than 10mW, the standard deviation for repeated measurement becomes smaller than ${\pm}$2%.

  • PDF

On the Study of the Period Measurement of Ultrasonic Signal in Damaged Vehicle Tire (자동차 타이어 손상에 의한 초음파 신호 주기 측정에 관한 연구)

  • Park, Jung-Im;Lim, Seung-Gak;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.47-52
    • /
    • 2011
  • We studied about the damaged tire decision algorithm that measured dominant period of ultrasonic signal due to a foreign material on the friction between tire and road surface. We computed the power spectrum about the envelope of ultrasonic signal acquired from the damaged tire, then proposed the dominant period decision algorithm by statistical power threshold value. As the result of simulation, when driving by the speed of 80km/h, the 100ms of dominant period that measured in the proposed algorithm is more accurate than the 97.6ms of power spectrum peak period referenced on the average period of ultrasonic signal envelope peak, 101.24ms.

The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro (압전방식 초음파 치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Cha, Kuk-Bong;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.139-148
    • /
    • 2009
  • Purpose: Ultrasonic scalers have been widely used for removing biofilm which is considered as major etiologic factor of periodontal disease. The purpose of this study was to evaluate the effect of working parameters of piezoeletric ultrasonic scaler with scaler tip (No. 1 tip) on casting gold alloy removal. Methods: Type III dental casting gold alloy (Firmilay$^{circledR}$, Jelenko Inc, CA, USA) was used as substitute for tooth substance. Piezoeletric ultrasonic scaler and No.1 scaler tip (P-Max$^{circledR}$, Satelec, France) were selected. The selected working parameters were mode (P mode, S mode), power setting (2, 4, 8) and lateral force (0.5 N, 1.0 N, 2.0 N). The effect of working parameters was evaluated in terms of ablation depth, ablation width and ablation area. Results: Mode influenced ablation depth and ablation area. Power also influenced ablation depth and ablation area. Especially, Power 2 and power 8 showed statistically significant difference. Lateral force had influence on ablation width, and 0.5 N resulted significant increase compared with 1.0 N and 2.0 N. Ablation depth was influenced by mode, power and lateral force and defect width was influenced by lateral force. Ablation area was influenced by mode and power. Conclusions: It can be concluded that the use of piezoelectric ultrasonic scaler with No. 1 scaler tip in S mode and high power may result in significant loss of tooth substance.

Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study

  • Kwak, Sang-Won;Moon, Young-Mi;Yoo, Yeon-Jee;Baek, Seung-Ho;Lee, WooCheol;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.276-281
    • /
    • 2014
  • Objectives: The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods: The apical 3 mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results: There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions: Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

Output power maximizing in ultrasonic transducer driven at 1MHz utilizing auto-tune MOS-FET RF inverter

  • Mizutani, Yoko;Suzuki, Taiju;Ikeda Hiroaki;Yoshida, Hirofumi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.87-90
    • /
    • 1995
  • When the ultrasonic transducer operating at l MHz for use in cleaning semiconductor wafers or other industsrial materials is driven from the MOS-FET DC-to RF inverter, the output power severely depends on the frequency of operation since the quality factor of the transducer is high. In order to tune to the eresonating frequency of the ultrasonic transducer, the drive signal frequency of the MOS-FET power inverter is automatically scananed until the frequency is set at the resonating frequency of the ultrasonic transducer is maximized. The control circuit consists of an output power sensing circuit, a PLL controller, a frequency standard, and other peripheral circuits. The operation was satisfactory when the transducer having an output of 600 W at 1 MHz was used.

  • PDF

Structural and Dielectric Properties of Epoxy-Organoclay Nanocomposites using Power Ultrasonic Dispersion (초음파 분산을 이용한 Epoxy-Organoclay 나노콤포지트 구조적 그리고 유전특성에 관한 연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1572-1578
    • /
    • 2008
  • The effect of the organoclay_10A nanoparticles on the DSC and Structural and Dielectrics Properties(1Hz-1MHz) for epoxy/Organoclay_10A Nanocomposites has been studied. Dielectric properties of epoxy-Organoclay nanocomposites were investigated at 1, 3, 5, 7, 9 filler concentration by weight. Epoxy nanocomposites samples were prepared with good dispersion of layered silicate using power ultrasonic method in the particles. As structural analysis, the interlayer spacing have decreased with filled nanoparticles contents increase using power ultrasonic dispersion. The maximum increase interlayered spacing was observed to decease for above 5wt% clay loading. The other hand, as decrease with concentration filler of the layered silicate were increased dispersion degree of nanoparticles in the matrix. The interesting dielectric properties for epoxy based nanocomposites systems are attributed to the large volume fraction of interfacesin the bulk of the material and the ensuring interactions between the charged nanoparticle surface and the epoxy chains.

Study on the Bonding Pad Lift Failure in Wire Bonding (와이어 본딩시 본딩 패드 리프트 불량에 관한 연구)

  • 김경섭;장의구;신영의
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1079-1083
    • /
    • 1998
  • In this study, ultrasonic power of Aluminum wire bonder, bond time and bond force are investigated and valued in order to minimize failure of bonding pad lift. We also tried to control those 3 factors properly. We got the conclusion that if we turn down the ability of ultrasonic power or bond time, we can get a pad lift from a boundary between bond pad ad wire because pad metal and wire joining is unstable, but it is best condition when it ultrasonic power is 100∼130unit, bond time is 15∼20msec and bond force is 4∼6gf.

  • PDF

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.

Comparison of Sewage Sludge Solubilization through Different Pretreatment Methods (전처리 방법에 따른 하수슬러지 가용화 비교연구)

  • Kwon, Jae-Hyun;Kim, Bong-Jun;Kim, Min-Kyu;Yeom, Ick-Tae;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.567-573
    • /
    • 2003
  • The pretreatment process was carried out to solubilize the sewage sludge for enhancing its biodegradability using alkaline treatment, ultrasonic treatment(15kHz), ozone treatment and different combination of these three methods: alkaline followed by ultrasonic as well as ozone, and ultrasonic followed by alkaline. The solubilization efficiency was evaluated based on the SCOD/TCOD ratio and VSS/TS ratio. In results, the proper condition of alkaline treatment was shown as 30meq/l of NaOH, pH 12 and 3hours of reaction time. Solubilization efficiency increased to 17% from initial 2% based on SCOD/TCOD ratio under this condition. In ultrasonic treatment, the higher ultrasonic power, the longer treatment time and the lower sludge volume resulted in higher solubilization respectively. There was a rapid increase in solubilization efficiency after 20 minute, then it was measured as 32% of SCOD/TCOD ratio in 1 hour at a ultrasonic power of 1,300W with 1/sludge. Solubilization efficiencies in combined treatment using alkaline and ultrasonic were 47-53% higher than single treatment at a sonicated time of 1 hour. Ozone treatment followed by alkaline treatment also represented the enhanced solubilization compared to ozone treatment. Therefore, ultrasonic or ozone treatment assisted by alkaline could achieve the short treatment time as well as high solubilizetion efficiency.