• Title/Summary/Keyword: Ultrasonic Intensity

Search Result 165, Processing Time 0.024 seconds

A Study on Development of Composite Ultrasonic Transducer Assembly with Drug Transfer Function (약물 이송기능을 갖는 복합구조 초음파 변환기 어셈블리 개발에 관한 연구)

  • Noh, Si-Cheol;Kim, Ju-Young;Yoo, Byeong-Cheol;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.353-359
    • /
    • 2017
  • The sonophoresis, a representative low-intensity ultrasonic therapy, is a technique for delivering the drugs into the epidermis, dermis and skin appendages by using physical vibration and heat effects of the ultrasonic waves. Sonophoresis could increases the delivering and absorption efficiency of the drugs usually consisting of hydrophilic molecules and macromolecules. In addition, it has the advantage of being effective in delivering drugs with relatively large molecular sizes such as insulin or lipid. In this study, we proposed a multi-structure ultrasonic transducer assembly with a large-size single piezoelectric element and a drug delivery function at the treatment site for efficient sonophoresis treatment. Futhermore, a transducer assembly structure capable of raising and maintaining the temperature of the treatment site was proposed and evaluated for effectiveness. The transducer assembly proposed in this study is expected to improve the efficiency of sonophoresis by providing a constant amount of drug, and assisting drug delivery through heating the treatment site.

Degradation of PAHs in Aqueous Solution by UV Energy and Ultrasonic Irradiation (액상 PAHs의 자외선에너지와 초음파를 이용한 분해)

  • Kwon Sung-Hyun;Kim Jong-Hyang;Cho Dae-Chul
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.669-676
    • /
    • 2006
  • PAHs are major pollutants that are widely distributed in soil and groundwater environment, so that may be regarded as carcinogens. We investigated the degradation kinetics of PAH in aqueous solution when low pressure UV energy and ultrasonic irradiation were applied. Phenanthrene and pyrene were used as model compounds. The degrees of degradation of these compounds with time were analyzed with a GC/MSD (SIM-mode). UV photolysis experiments showed that phenanthrene was reduced by 90 -67% at initial concentrations of 1 ppm to 8ppm whilst it decreased to 50% at 10 ppm. Under the same conditions pyrene was degraded up to about 75% at lower initial concentrations but the reduction efficiency dropped to a level of 34 to 29% at the higher concentrations above 8 ppm. The reaction orders for phenanthrene and pyrene were found to be zero-th and ca. -0.4th order, respectively, thus implying that the reported assumption of pseudo 1st order reaction for some PAHs would be no longer valid. PAH degradation was roughly proportional to the intensity of UV (number of lamps), exhibiting maximum 92.5% of the degradation efficiency. The solution pH was lowered to 4.4 from 6.4 during the experiments partially because the carbons decomposed by the energy reacted with oxygen radicals to produce carbon dioxides. Ultrasonic irradiation on phenanthrene solutions gave relatively poor results which matched to 50 to 70% of degradation efficiency even at 2 ppm of initial concentration. Phenanthrene was found to be degraded more efficiently than pyrene for the two energy sources. Ultrasound also followed the same reaction kinetics as UV energy on PAH degradation.

Flaw Detection in Pipe-Welded Zone by Using Wavelet Transform and SH-EMAT (웨이브렛 변환과 SH-EMAT을 이용한 배관 용접부 결함 검출)

  • Lee, Jin-Hyuk;Kim, Dae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1511-1519
    • /
    • 2012
  • Pipe structures contain many welded zones, and ultrasonic tests are increasingly being performed by using automated testing devices in order to evaluate the weld integrity. An electromagnetic acoustic transducer (EMAT) is a noncontact transducer that can transmit or receive ultrasonic waves without a couplant. Furthermore, it can easily generate specific guided waves such as SH (shear horizontal) or Lamb waves by altering the design of the coil and magnet. Therefore, an EMAT should be useful for application to an automated ultrasonic inspection system. In this study, SH waves generated using an EMAT were applied to inspect the pipe-weld zone. To analyze the specific SH mode (SH0) from the SH wave signals, wavelet transform was applied. It was found that flaws could be detected precisely because the intensity of the $SH_0$ mode-frequency, which is analyzed by using wavelet transform, is proportional to the length of the flaw.

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

Special Issue for Biomedical Ultrasound: Towards Further Advances in Fundamentals and Applications by Comprehensive Reviews

  • Kim, Yong-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3E
    • /
    • pp.107-110
    • /
    • 2010
  • In this paper, the rationale and contents of the special issue of the Journal of the Acoustical Society of Korea regarding comprehensive reviews on past, present and future of biomedical ultrasound are described. Brief descriptions of invited articles are given, and efforts by all contributing authors are gratefully acknowledged.

A Study on the Development of High-Intensity Focused Ultrasound Skin Treatment System Through Frequency Output Control Optimization (주파수 출력 제어 최적화를 통한 고강도 집속 초음파 피부치료 시스템 개발 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1022-1037
    • /
    • 2022
  • It is important to develop a transducer that generates uniform output power through frequency control of the HIFU at 4 MHz frequency for the high intensity focused ultrasound (HIFU) skin diseases treatment. In this paper, a 4 MHz frequency band HIFU system for skin disease treatment was designed, manufactured and developed. In HIFU, even for the ultrasonic vibrator in the 4 MHz frequency band, the characteristics of the output power of the HIFU are different depending on the difference in the thickness of the PZT material. Through the development of a system amplifier, the sound output of the HIFU transducer was improved to more than 48 W and uniform output power control was possible. And, it is possible to control the output power even in a frequency band of 4.0 to 4.7 MHz, which is wider than 4.0 MHz, and shows the resonance frequency of the transducer. The maximum output power for each frequency was 49.969 W and the minimum value was 48.018 W. The maximum output power compared to the minimum output power is 49.969 W, which is uniform within 4.1%. It was confirmed that the output power of the HIFU through the amplifier can be uniformly controlled in the 4 MHz frequency band.

Assessment of flow-accelerated corrosion-induced wall thinning in SA106 pipes with elbow sections

  • Seongin Moon;Jong Yeon Lee;Kyung-Mo Kim;Soon-Woo Han;Gyeong-Geun Lee;Wan-Young Maeng;Sebeom Oh;Dong-Jin Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1244-1249
    • /
    • 2024
  • A combination of flow-accelerated corrosion (FAC) tests and corresponding computational fluid dynamics (CFD) tests were performed to determine the hydrodynamic parameters that could help predict the highly susceptible location to FAC in the elbow section. The accelerated FAC tests were performed on a specimen containing elbow sections fabricated using commercial 2-inch carbon steel pipe. The tests were conducted at flow rates of 9 m/s under the following conditions: water temperature of 150 ℃, dissolved oxygen <5 ppb, and pH 7. Thickness reduction of the specimen pipe due to FAC was measured using ultrasonic testing. CFD was conducted on the FAC test specimen, and the turbulence intensity, and shear stress were analyzed. Notably, the location of the maximum hydrodynamic parameters, that is, the wall shear stress and turbulent intensity, is also the same location with maximum FAC rate. Therefore, the shear stress and turbulence intensity can be used as hydrodynamic parameters that help predict the FAC-induced wall-thinning rate. The results provide a method to identify locations susceptible to FAC and can be useful for determining inspection priority in piping systems.

Walking Assistance Device for Prevention of Accidents of Visually Impaired People (시각장애인의 사고예방을 위한 다기능 보행 보조 장치)

  • Sim, Jae-Man;Lee, Hyeong-Wook;Shin, Joo-Yong;Kim, Ki-Won;Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1241-1248
    • /
    • 2019
  • In this paper, an auxiliary device was implemented to help blind people more safely from obstacles or risk factors while walking. The ultrasonic sensors detect obstacles in the front, so that the noise gap and the vibration intensity of the buzzer can be heard differently by distance and angle, and so the situation can be perceived by pedestrians. When the ambient light becomes darker than the light intensity set using the CdS resistance value of the light sensor, the LED automatically turns on, makes it easier for pedestrians to recognize the position of the auxiliary device through buzzer if the pedestrian misses the aid using the gyro sensor's slope. Moreover, the location and situation of the blind were transmitted to the caregiver to check safety and behavior using GPS and Bluetooth.

Effect of light, ultrasonication and liquid smoke on germination of proso millet (Panicum miliaceum L.) seeds

  • Kim, Min Geun;Kim, Young Ae;Jung, Ki-Yeul;Kim, Du Hyun
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.213-213
    • /
    • 2017
  • High quality seed of proso millet that has high germination percentage, germination speed, and uniformity demanded to increases rates of mechanization in cereal crop cultivation. In order to improve germination characteristics, proso millet seeds were treated with red light, ultrasonication and liquid smoke (LS) solution that generated from hickory wood. All treatments were performed in seed priming solution with 100mM $NH_4NO_3$ at $15^{\circ}C$ for 24hrs under aeration condition. Seeds were exposed under light intensity of 2000 lux for 15m, 30m, 60m, and 120m in priming solution. Ultrasonic treatment was performed at 60%, 80%, and 100% intensity of 21.6 KHz for 5m, 10m, and 20m in priming solution. For LS treatment seed were soaked in 0%, 0.5%, 1.0%, 5.0% and 10.0% of diluted solution with $dH_2O$ or 100mM $NH_4NO_3$ solution. The effect of seed treatment was evaluated with germination percentage (GP), mean germination time (MGT), germination index (GI), germination rate (GR), Germination uniformity (GU) and heath seed percentage (HS). Our results demonstrate that red light (15min) or ultrasonication (21.6kHz, 5min) treatment improved MGT, GI, GR, and GU comparing to untreated control. Importantly, we show that LS treatments have significant effect on the health seedling and germination characteristics. Proso millet seeds that treated with 5% LS solution for 24hrs improves HS up to 97% that similar results obtained in 100mM $NH_4NO_3$ priming for 24hrs. The combined treatment with LS solution and 100mM $NH_4NO_3$ priming were not effective in all treatments. Our results demonstrate that treating seeds with LS or 100mM $NH_4NO_3$ priming or ultrasonication improves germination characteristics. The methods described here will help advance research using this species by increasing the germination performance at which successive seed pellet process.

  • PDF

Study on Sonochemical Synthesis and Characterization of CdTe Quatum Dot (초음파 방법을 이용한 CdTe 양자점의 합성 및 특성에 관한 연구)

  • Yoo, Jeong-yeol;Kim, Woo-seok;Park, Seon-A;Kim, Jong-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.571-575
    • /
    • 2017
  • In this study, cadmium telluride (CdTe) quantum dots were synthesized by using ultrasonic irradiation method. Optical properties and structural characteristics of the CdTe quantum dots were analyzed by two main variables; the ratio of the precursor and the synthesis time. As the synthesis time increased, the band gap reduction was observed with the growth of CdTe quantum dots. As for the luminescence properties, the red shift appeared at 510~610 nm wavelength range. Also, it was confirmed that the red shift occurs rapidly as the ratio of Te increases. According to PL peak intensity, the highest intensity was shown at 180 to 240 min. Structural characteristics of CdTe quantum dots were investigated through XRD and TEM, and the cubic zinc blend structure was observed. The size of quantum dots was about 2.5 nm and uniformly dispersed when the synthesis time took 210 min. In addition, the apparent crystallinity was discovered in FFT image.