• Title/Summary/Keyword: Ultrasonic Attenuation

Search Result 222, Processing Time 0.02 seconds

UT Inspection Technique of Cast Stainless Steel Piping Welds Using Low Frequency TRL UT Probe (저주파수 TRL 탐촉자를 이용한 Cast Stainless Steel 배관 용접부 초음파탐상기법)

  • Shin, Keon-Cheol;Chang, Hee-Jun;Jeong, Young-Cheol;Noh, Ik-Jun;Lee, Dong-Jin
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.29-36
    • /
    • 2010
  • Ultrasonic inspection of heavy walled cast austenitic stainless steel(CASS)welds is very difficult due to complex and coarse grained structure of CASS material. The large size of anisotropic grain strongly affects the propagation of ultrasound by severe attenuation, change in velocity, and scattering of ultrasonic energy. therefore, the signal patterns originated from flaws can be difficult to distinguish from scattered signals. To improve detection and sizing capability of ID connected defect for heavy walled CASS piping welds, the low frequency segmented TRL Pulse Echo and Phased Array probe has been developed. The experimental studies have been performed using CASS pipe mock-up block containing artificial reflectors(ID connected EDM notch). The automatic pulse echo and phase array technique is applied the detection and the length sizing of the ID connected artificial reflectors and the results for detection and sizing has been compared respectively. The goal of this study is to assess a newly developed ultrasonic probe to improve the detection ability and the sizing of the crack in coarse-grained CASS components.

  • PDF

A Study on the Evaluation of Material Degradation of 1Cr-lMo-0.25V Steel using Ultrasonic Techniques (초음파법을 이용한 1Cr-lMo-0.25V강의 열화도 평가에 관한 연구)

  • Kim, Jeong-Pyo;Seok, Chang-Seong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.2116-2124
    • /
    • 2001
  • It's required mechanical properties of in-service facilities to maintain safety operation in power plants as well as chemical plants. In this studdy the four classes of the thermally aged 1Cr-lMo-0.25V specimens were prepared using an artificially accelerated aging method at 630$\^{C}$. Ultrasonic tests, tensile tests, K$\_$IC/ tests and hardness tests were performed in order to evaluate the degree of degradation of the material. The mechanical properties were decreased as degraded, but the attenuation coefficient and the harmonic generation level of a ultrasonic signal were increased. Expecially the nonlinear parameter derived from the harmonic generation level is sensitive and will be a good parameter to evaluate the material degradation.

The Estimation of Neutron Fluence in Nuclear Reactor Vessel Materials by the Analysis of Ultrasonic Characteristics (초음파특성 분석에 의한 원자로 재료의 중성자 조사량 예측)

  • Lee, Sam-Lai;Chang, Kee-Ok;Kim, Byoung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.307-312
    • /
    • 2001
  • Ultrasonic signals from Charpy impact test specimen have been analyzed in order to evaluate the integrity of reactor pressure vessel. Base and weld metal that were extracted from reactor vessel doting plant outages according to the schedule of the surveillance test required by the related regulations have been used and the ultrasonic test parameters including velocity, attenuation, etc. showed a close correlations with the amount of neutron irradiation for base metal, relatively homogeneous materials. This result showed certain possibility where a nondestructive method could be used to predict the fluence of the Irradiation due to neutron in nuclear reactor vessel materials.

  • PDF

A Study on Fatigue Damage Accumulation of MMC using Ultrasonic Wave and Acoustic Emission (초음파와 AE기법을 이용한 금속복합재료의 피로손상진전 평가)

  • 이진경;이준현
    • Composites Research
    • /
    • v.13 no.4
    • /
    • pp.1-10
    • /
    • 2000
  • SiC particulate reinforced metal matrix composites(MMCs) are emerging as candidate materials for the automobile and aerospace industries due to their significant increase in elastic modulus and strength compared to conventional metallic materials. However, in order to make successful application of MMCs, it is very important to understand micro-failure mechanism under cyclic loading because failure mechanism of MMC is dominated by accumulation of micro-failure due to applied loading. In this study, ultrasonic Lamb wave and acoustic emission(AE) have been used to monitor microscopic damage accumulation under cyclic loading for SiC particulate reinforced metal matrix composite(SiCp/A356). It was found that the change in velocity and attenuation of ultrasonic Lamb wave due to the increase of loading cycles could be characterized by three different stages corresponding to the microscopic fracture processes. The characteristic of AE signal at each stage was analyzed and discussed by comparing with the change of ultrasonic characteristic in MMCs.

  • PDF

The Characteristics of Ultrasonic Signals for Detecting Micro-Defects in Ti-6Al-4V Alloy (Ti-6Al-4V 합금의 내부 미소결함에 따른 초음파 신호 특성 연구)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Kubota, M.;Murakami, Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.591-597
    • /
    • 2001
  • Ti alloy is used for essential parts of aircraft for high temperature environment. Although Ti alloy has excellent performance in regard to mechanical properties, it is difficult ot find fatigue cracks by nondestructive ultrasonic inspection due to its two-phase microstructure, which consists of hard alpha and beta phases. Sound energy reflected from microstructural features in the component produces a background inspection noise which is seen even when no defects are present. This noise can inhibit the detection of critical internal defects such as pores cracks or inclusions. To obtain fundamental data on ultrasonic inspection of Ti alloy, ultrasonic testing was performed using a specimen with small drill holes and ultrasonic wave propagation velocites were measured.

  • PDF

Variations of Speed of Sound and Attenuation Coefficient with Porosity and Structure in Bone Mimics (뼈 모사체에서 다공율 및 구조에 대한 음속 및 감쇠계수의 변화)

  • Kim, Seong-Il;Choi, Min-Joo;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.388-394
    • /
    • 2010
  • In the present study, polyacetal bone mimics with circular cylindrical pores were used to investigate variations of speed of sound and attenuation coefficient with porosity and microarchitecture in bone. The speed of sound and attenuation coefficient of the 6 bone mimics with porosities from 0 % to 65.9 % were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. Independently of the structural properties of the bone mimics, the speed of sound decreased almost linearly with the increasing porosity. The attenuation coefficient measured at 1.0 MHz exhibited linear or nonlinear correlations with the porosity, depending on the structural properties of the bone mimics. These results are consistent with those previously published by other researchers using bone samples and mimics, and advances our understanding of the relationships of the ultrasonic parameters for the diagnosis of osteoporosis with the bone density and microarchitecture in human bones.

Measurement of Acoustic Properties of Polyurethane by the through Transmission Method (투과법을 이용한 폴리우레탄재료의 음향특성 측정)

  • 김태식;이기석;안봉영;이진형
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.40-47
    • /
    • 2000
  • To obtain the acoustic properties of dispersive polyurethane with high attenuation, through transmission method was applied by ultrasonic. In through transmission method, the sound velocity and attenuation coefficient of specimen were obtained by using Sachse's method which can be applied to small size specimen. But there is a problem when the reference signal is selected, so the result is not precise. The more precise acoustic properties of polyurethane was obtained when two specimens with different thickness were used. To predict the acoustic properties of low frequency range, the acoustic properties extended to the low frequency range were calculated by Kramers - Kronig relation. As a result, we studied on the relation between the sound velocity and the attenuation coefficient with frequency.

  • PDF

Ultrasonic Characteristics of Degraded Compacted Graphite Iron from 873 to 1,273 K (873~1,273 K에서 열화된 강화흑연강(Compacted Graphite Iron, CGI)의 초음파특성)

  • Lee, Soo-Chul;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.72-78
    • /
    • 2013
  • Compacted graphite iron 340 was carried out the heat treatment from 873 to 1,273 K. Compacted graphite iron 340 was evaluated relationship between the sound velocity, the attenuation coefficient and the tensile strength. The obtained results are as following. The signal strength of C scan images were weak according to increasing of heat treatment temperature and time. The amplitude of A scan and B scan was also low. This can be cause that the graphite was grown into the type of vermicular, and the many of grain boundary with ultrasound scattering were increase. The sound velocity was depend upon the heat treatment temperature and time, the attenuation coefficient had nothing to do with the temperature and time. The higher the heat treatment temperature, the tensile strength and the sound velocity were decreased. However, the tensile strength was proportional to the sound velocity. The higher tensile strength, the faster the sound velocity.

Propagation Characteristics of High-frequency Waves in an Elastic Waveguide (탄성 도파봉에서 고주파수 파동의 전파 특성)

  • Lee, Jung-Gu;Kim, Jin-Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.816-821
    • /
    • 2010
  • The paper presents a theoretical analysis on the propagation characteristics of the high-frequency wave in an elastic waveguide whose diameter is less than or similar to the wavelength. The theoretical results were verified by comparing them with the numerical results obtained by the boundary-element method. The ratio of the waveguide diameter to the wavelength affects the number of the existing wavenumber, and thus it affects the propagation characteristics. In the media with attenuation, the trend is similar to that in the media without attenuation except the decreasing amplitude.

A Study on the Phase Correction of ultratrasound transfer function (초음파 전달함수의 위상보정을 위한 연구)

  • Min, Yong-Ki;Lee, Kang-Ho;Choi, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.713-716
    • /
    • 1988
  • To characterize the bioloical tissues, the new methods to measure the frequency dependent attenuation are presented in this paper. In general, ultrasonic phase information was assumed by linear function of the frequency. But the minimum phase function which characterizes the frequency dispersion of tissue was derived in (2). It is very significant to measure the attenuation by using the minimum phase function to characterize the frequence dispersion of tissue. Also, we propose the phase correcting technique to take advantage of the idea that the distortion of amplitude component when the wave propagates through media.

  • PDF