• 제목/요약/키워드: Ultrasonic Application

검색결과 558건 처리시간 0.024초

나노계면 형성을 위한 초음파 진동자 위치보정을 위한 레이저 스캐닝 기술 (Laser Scanning Technology for Ultrasonic Horn Location Compensation to Modify Nano-size Grain)

  • 김경한;이제훈;김현세;박종권;윤광호
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1121-1126
    • /
    • 2014
  • To compensate location error of ultrasonic horn, the laser scanning system based on the galvanometer scanner is developed. It consists of the 3-Axis linear stage and the 2-Axis galvanometer scanner. To measure surface shape of three-dimensional free form surface, the dynamic focusing unit is adopted, which can maintain consistent focal plane. With combining the linear stage and the galvanometer scanner, the scanning area is enlarged. The scanning CAD system is developed by stage motion teaching and NURBS method. The laser scanning system is tested by marking experiment with the semi-cylindrical sample. Scanning accuracy is investigated by measured laser marked line width with various scanning speed.

원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구 (A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants)

  • 이승표;김진회
    • 한국압력기기공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

Gracey curet과 Ultrasonic scaler 사용 시의 치면 특성의 주사현미경적 연구 (Scanning electron microscopic study on characteristics of tooth surface when using gracey curet and ultrasonic scaler)

  • 남용옥;이화정;최미혜
    • 한국치위생학회지
    • /
    • 제16권4호
    • /
    • pp.635-641
    • /
    • 2016
  • Objectives: The purpose of this study is to assess the characteristics of tooth surface after using Gracy curet and Ultrasonic scaler Methods: In this study, 12 teeth extracted were used. 12 specimens were divided into three groups with the same numbers, which were classified into Control group, Gracy curet use group, and Ultrasonic scaler use group, and after performing instrument operation, we measured the roughness and the loss degree of tooth surface by using SEM. Results: In groups using Gracy curet and Ultrasonic scaler, the roughness and the loss of tooth surface increased significantly(p<0.05). In the roughness of groups using Gracy curet and Ultrasonic scaler, Ultrasonic scaler group was higher in crown, but Gracy curet group was higher in root. As a result of observation through SEM, the roughness and the loss degree increased in order of Control group, Ultrasonic scaler use group, and Gracy curet use group. Conclusions: Taken together above results, both hand instrument and ultrasound equipment create roughness and loss in crown and in root, and hand instruments makes rougher than ultrasonic instruments in root, so it is thought to require thorough and accurate technical application not to damage tooth surface when removing plaque.

Phased Array트랜스듀서에 있어서 구성 압전소자수의 변화에 따른 초음파 빔 전파 특성의 수치 해석 (Numerical Analysis of Ultrasonic Beam Profile Due to the Change of the Number of Piezoelectric Elements for Phased Array Transducer)

  • 최상우;이준현
    • 비파괴검사학회지
    • /
    • 제19권3호
    • /
    • pp.207-216
    • /
    • 1999
  • 일반적인 하나 또는 두개의 압전소자를 사용하는 트랜스듀서에 비하여 다수의 압전소자를 사용하는 어레이 트랜스듀서는 각 압전소자에 가해지는 펄스의 지연시간을 제어함으로써 초음파 빔을 임의의 지점에 집속시킬 수 있고 기계적 구동없이 임의의 방향으로 조향시켜 실시간 주사를 할 수 있는 장점이 있다. 페이즈드 어레이 트랜스듀서의 설계조건은 압전소자의 수. 압전소자의 크기 그리고 압전소자 사이 간격 등 여러가지가 있으며, 본 연구에서는 그 중에서 압전소자수의 변화에 따른 초음파 빔의 특성을 호이겐스의 원리를 이용한 수평횡파의 시뮬레이션을 통하여 평가하였다. 그 결과 초음파 빔은 조향각이 증가 할수륵 음압이 감소하며, 초음파 빔 특성도 점차적으로 분산됨을 알 수 있었고 또한, 초점거리가 증가할수록 초점에서의 집속효과는 감소하고, 압전소자의 수가 증가되면 집속효과는 향상됨을 알 수 있었다.

  • PDF

액체 연료의 분무를 위한 압전 세라믹 진동자의 설계 및 동작 특성 (The Design and Driving Characteristics of Piezoelectric Ceramic Oscillator for Spraying of Liquid Material)

  • 이수호;석정영;류기홍;김한근;김진규;류주현;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.686-689
    • /
    • 2002
  • The application of the ultrasonic nozzle has been extended because it is possible atomization of liquid material. In this study, the characteristics of the ultrasonic nozzle and ceramic oscillator were investigated. The oscillator for the ultrasonic nozzle were made piezoelectric ceramic of $Pb[(Sb_{1/2}Nb_{1/2})_{0.035}-(Mn_{1/3}Nb_{2/3})_{0.065}-(Zr_{0.49}Ti_{0.51})_{0.90}]O_3$. The electromechanical coupling factor$(k_p)$ and mechanical quality factor$(Q_m)$ showed the values of 0.555, 1,214 respectively when the Zr/Ti ratio was 49/51. Moreover, this oscillator will have the temperature stability because it's curie temperature is $322[^{\circ}C]$. The driving current of ultrasonic nozzle showed the value of 80[mA] when the driving time was 10[min.]. Also, The surface temperature of ceramic oscillator showed $80[^{\circ}C]$ at driving time 10[min.] We knew that the ultrasonic nozzle had stabile driving above 10[min.].

  • PDF

Field Application of an Ultrasonic Testing for Reconstructing CT Images of Wooden Columns

  • Lee, Sang-Joon;Park, Chun-Young;Kim, Kwang-Mo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권2호
    • /
    • pp.148-154
    • /
    • 2009
  • This research examined the applicability of using an ultrasonic test to reconstruct CT images of an ancient wooden building. Most of the columns in the building are severely deteriorated due to termite attacks or the effect of weathering. Ultrasonic CT images of the columns were used to create highly accurate digital reconstructions, despite a lack of the data caused by parts of the building walls being buried. Another semi-NDE technique, a drilling test based on resistography, was applied in order to verify the ultrasonic test results. The discrepancy in detection between two methods is believed to be due to the fundamental differences between two methods. The performance of the ultrasonic test was hindered by poor surface conditions and this technique tended to over-estimate the size of cavities produced by termites or other insects. Nevertheless, the deterioration detected was in many ways congruent with the drilling test results

Optimization of ultrasonification of slaughter blood for protein solubilization

  • Jeon, Yong-Woo
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.163-169
    • /
    • 2015
  • In this study, we attempted to solubilize protein in slaughter blood (SB) using ultrasonic technology. The application of ultrasonic technology can make enzymatic degradation of SB more effective, which has no comparable alternative for treatment. The SB was homogenized by grinding it for 10 minutes at 10,000 rpm as a pretreatment for preventing its clotting, and then ultrasonic treatment was attempted to solubilize protein in SB. To maximize the efficiency of ultrasonic treatment for SB, the optimum condition of ultrasonic frequency (UF) was determined to be 20 kHz. To optimize the operation conditions of ultrasonification with 20 kHz of frequency, we used response surface methodology (RSM) based on ultrasonic density (UD) and ultrasonification time (UT). The solubilization rate (SR) of protein (%) was calculated to be $101.304-19.4205X_1+0.0398X_2+7.9411X_1{^2}+0.0001X_2{^2}+0.0455X_1X_2$. From the results of the RSM study, the optimum conditions of UD and UT were determined at 0.5 W/mL and 22 minutes, respectively, and SB treated under these conditions was estimated to have a 95% SR. Also, experimentally, a 95.53% SR was observed under same conditions, accurately reflecting the theoretical prediction of 95%.

압밀촉진을 위한 초음파의 활용 (Fast Consolidation of Soft Clay due to Ultrasonic Energy)

  • Kim, Young-Uk;Song, Young-Karb;Kim, Boyung-Il
    • 한국지반공학회논문집
    • /
    • 제20권2호
    • /
    • pp.67-73
    • /
    • 2004
  • 준설매립 및 연약지반 처리에 있어 압밀촉진 공법들에 대한 연구가 활발하다. 본 연구에서는 초음파를 사용하여 압밀촉진을 유발하고자 하였고 그 영향 정도를 실내실험을 통하여 조사하였다. 실내시험은 특별히 제작된 압밀시험기를 사용하였으며 압밀시험 중 초음파를 시료에 직접 가할수 있도록 고안되었다. 압밀시험 재료로는 원심력 시험기를 사용하여 원하는 조건에 맞는 동질의 시료를 제작하여 사용하였으며 초음파 강도, 처리 시간을 달리하여 시험을 실시하였다. 시험결과 초음파가 압밀에 미치는 영향은 큰 것으로 나타났으며 초음파 처리의 영향에 미치는 정도가 시험조건에 따라 다르게 나타났다. 본 연구의 결과를 이용하여 초음파에 의해 압밀촉진을 위한 공법개발의 가능성을 파악하였다.

초음파 진동 딥 드로잉 공정에서의 마찰감소효과 분석을 위한 유한요소해석 및 실험 (FEA and Experiment Investigation on the Friction Reduction for Ultrasonic Vibration Assisted Deep Drawing)

  • 김상우;손영길;이영선
    • 소성∙가공
    • /
    • 제23권7호
    • /
    • pp.413-418
    • /
    • 2014
  • The current study presents experimental and numerical results on the effect of ultrasonic vibrations on a cylindrical cup drawing of a cold rolled steel sheet(SPCC). An experimental apparatus, which can superimpose high frequency oscillations during deep drawing, was constructed by installing on the tooling ultrasonic vibration generators consisting of a piezoelectric transducer and a resonator. Conventional and vibration-assisted cylindrical deep drawing tests were conducted for various drawing ratios, and the limiting drawing ratios(LDR) for both methods were compared. To evaluate quantitatively the contribution from the ultrasonic vibrations to the reduction of friction between tools and material finite element analyses were conducted. Through a series of parametric analyses, the friction coefficients, which minimized the differences of punch load data between the experiments and simulations, were determined. The results show that the application of ultrasonic vibration effectively improves the LDR by reducing the friction between the tools and the material.

초음파 센서의 1차 정합층 두께에 따른 가스탱크 미세누설 수신특성 (Gas Tank Microleakage Reception Characteristics According to Thickness of the First Matching Layer of Ultrasonic Sensor)

  • 서원준;손성진;임석연
    • Tribology and Lubricants
    • /
    • 제37권5호
    • /
    • pp.164-171
    • /
    • 2021
  • Ultrasonic sensors show various reception characteristics based on the density of the measurement medium; hence, they are used in various fields to benefit from the characteristics of ultrasonic signals. In this study, the reception characteristics according to the thickness of the first matching layer are compared and analyzed for application to gas tank microleak detection. Accordingly, three types of sensors are manufactured with varying thicknesses of the first matching layer, namely 4.8 mm, 5.1 mm, and 5.5 mm; further, a direct measurement method is used wherein the sensor is attached to the inside of the chamber. Experiments are conducted to observe the phase change due to microleakage, which is the most linear in the sensor with the 4.8 mm thick first matching layer. This is assumed to be the result of stable signal transmission and reception with little phase deviations over time because the first matching layer is closest to the ultrasonic wavelength. The other sensors show nonlinear results with increasing thickness of the first matching layer. Through this study, it is found that appropriately selecting the thickness of the first matching layer of the ultrasonic sensor can greatly influence sensor reliability.