• Title/Summary/Keyword: Ultra-Filtration(UF)

Search Result 27, Processing Time 0.021 seconds

Evaluation of Coagulation-UF Process Considering Residual Aluminuim Concentration as Seawater Desalination Pretreatment (해수담수화 전처리 공정으로써 잔류 알루미늄 농도를 고려한 응집-UF 공정 연구)

  • Son, Dong-Min;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.495-502
    • /
    • 2013
  • This work was performed to investigate proper condition of coagulation treatment as UF process pretreatment that consider UF permeate flux and residual Al concentration. The coagulant used an alum as $Al_2(SO_4)_3{\cdot}16H_2O$ and PACl (r = 1.5) made this study. The experiment was tested in adjusting conditions such as alum dose, flocculation time and coagulation pH of seawater. Consequently, higher coagulant dose lead to elevation of UF permeate flux while residual aluminium also increased in condition of pH 8.0. The most suitable condition which has a good permeate flux and low residual aluminium, in this works, was coagulant dose of 0.7 mg/L (as Al, alum) and 1.2 mg/L (as Al, PACl) and coagulation pH 6.5. In addition, applying the flocculation time with 1.2 mg/L of PACI reduced. The flocculation time reduced UF permeate flux in using alum.

Preparation of Yeast Hydrolysate Enriched in Cyclo-His-Pro (CHP) by Enzymatic Hydrolysis and Evaluation of Its Functionality

  • Lee, Hyun Jung;Son, Heung Soo;Park, Chung;Suh, Hyung Joo
    • Preventive Nutrition and Food Science
    • /
    • v.20 no.4
    • /
    • pp.284-291
    • /
    • 2015
  • In this study, we attempted to enrich cyclo-His-Pro (CHP) using enzymatic hydrolysis of yeast and to evaluate the functionality of yeast hydrolysate (YH)-enriched CHP. Flavourzyme offered a better performance in enhancing CHP content than other proteases. The CHP enrichment conditions were optimized as follows: addition of 1% Flavourzyme, 48-h incubation at 60oC, and pH 6.0. The CHP content significantly increased by 20-fold after ultra-filtration (UF). Maximal CHP translation was obtained after heating for 8 h at 50oC and pH 7.0. YH showed poor foaming capacity between pH 3.0 to 9.0. The emulsifying activities of YHs were slightly higher at near acidic pH. Increase in heating temperature and time resulted in decreased CHP content. The results indicate that YH is more heat stable after UF. Therefore, the CHP in YH after UF can be used as a food additive with physiological CHP activity and high heat stability.

A feasibility study of a pilot scale two-phase anaerobic digestion with ultra filtration for the treatment of garbage leachate (음식물 탈리액 처리를 위한 파일럿 규모의 막결합형 2상 혐기성 소화 공정 가능성 평가)

  • Lee, Eun-young;Heo, Ahn-hee;Kim, Hyung-kuk;Kim, Hee-jun;Bae, Jae-ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.539-545
    • /
    • 2009
  • A feasibility of a pilot scale two-phase anaerobic digestion with ultra filtration system treating garbage leachate were evaluated. The treatment system consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. The average COD removal efficiency of the treatment system was 95% up to the OLR of 3.1 g COD/L/d. The higher COD removal efficiency with membrane unit resulted from the removal of some portion of soluble organics by membrane as well as particulate materials. When the membrane unit was in operation, bulk liquid in acidogenic and methanogenic reactors was partially interchanged, which maintained the acidogenic reactor pH over 5.0 without external chemical addition. Also, with the production of methane in the acidogenic reactor, the organic loading rate of the methanogenic reactor reduced. The initial flux of the membrane unit was $50{\sim}60L/m^2/hr$, but decreased to $5 L/m^2/hr$ after 95 days of operation due to clogging caused by particulate materials such as fibrous materials in garbage leachate. To prevent clogging caused by particulate materials, a pretreatment system such as screening is required. With the improvement with membrane unit operation, the two-phase anaerobic digestion with ultra filtration system is expected to have the possibility of treating garbage leachate.

Color Removal of the Wastewater containing the Pigml:mts using Wastewater Treatment Technologies (안료폐수의 탈색연구)

  • Lee, Byeong-Kyu;Cho, Sung-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.429-439
    • /
    • 2000
  • Various wastewater treatment technologies were applied for decolorization and disposal of the wastewater containing the pigments, which consist of Lake Red C(Barium) or/and Lithol Rubine(Calcium) pigments. In an application of ozonation $COD_{Mn}$ was generally decreased with an increase of amounts of ozone applied, however, the decolorization effect was not that good except for Lithol Rubine series. In an application of Fenton oxidation and electrochemical process, a good $COD_{Mn}$ removal effect for all the pigment wastewater and a slight decolorization effect for a part of Lithol Rubine series were observed. In an application of ultra filtration(UF) and reverse osmosis(RO), an excellent $COD_{Mn}$ removal and decolorization(almost 100%) effects of all the pigment wastewater were observed. Thus the water treated by the UF and RO could be reusable and thus save operating costs of the pigment manufacturing plants.

  • PDF

Effects of Concentrated Pig Slurry Separated from Membrane Filter and Several Environment-Friendly Agro-Materials Mixtures on the Growth and Yield of Lettuce (Lactuca sativa L.) in Hydroponics (막분리 돈분농축액비와 몇가지 친환경농자재의 혼합액이 수경재배에서 상추의 생육과 수량에 미치는 영향)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2010
  • This experiment was conducted to investigate the effects of concentrated pig slurry separated from membrane filter and by environment-friendly agro-materials mixtures on growth of lettuce in hydroponics. The swine waste treatment system having a ultra filtration and a reverse osmosis process was designed in this study. Filtration of pig slurry was necessary to prevent the hose clogging in hydroponics. Primary separation using ultra filter was followed by concentration by RO (Reverse Osmosis). The concentrated pig slurry (CS) was mixed by five different environment-friendly agro-materials mixtures. The chemical nutrient solution was the solution of National Horticulture Research Station for the growth of lettuce. The concentration of nutrient solution in hydroponics was adjusted a range of 1.5 mS/cm in EC. The concentrated pig slurry was low in phosphorus(P), suspended solid and heavy matal, but rich in potassium (K). The concentrated slurry was lowest in the growth characteristics of leaf lettuce. And also SPAD value in leaf was reduced in plot treated with concentrated slurry. But the growth of lettuce in the mixtures plot (CS+BM+AA, CS+BM+AA+SW) in hydroponics was significantly high compared to concentrated slurry. The fresh yield of lettuce was 78, 84% that of nutrient solution as 131.9, 142.2g in plot of CS+BM+AA and CS+BM+AA+SW, respectively. Our studies have shown that it is possible to produce organic culture using concentrated slurry and environment-friendly agro-materials mixture, although growth is slower than when using a conventional inorganic hydroponic solution.

Evaluation of flux stabilisation using Bio-UF membrane filter on KZN Rivers, South Africa

  • Thoola, Maipato I.;Rathilal, Sudesh;Pillay, Lingam V.
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.313-325
    • /
    • 2016
  • South Africa recognises piped water as the main source of safe drinking water supply. Remote areas do not have access to this resource and they rely solely on surface water for survival, which exposes them to waterborne diseases. Interim point of use solutions are not practiced due to their laboriousness and alteration of the taste. Bio-ultra low pressure driven membrane system has been noted to be able to produce stable fluxes after one week of operation; however, there is limited literature on South African waters. This study was conducted on three rivers namely; Umgeni, Umbilo and Tugela. Three laboratory systems were setup to evaluate the performance of the technology in terms of producing stable fluxes and water that is compliant with the WHO 2008 drinking water guideline with regards to turbidity, total coliforms and E.coli. The obtained flux rate trends were similar to those noted in literature where they are referred to as stable fluxes. However, when further comparing the obtained fluxes to the normal dead-end filtration curve, it was noted that both the Umbilo and Tugela Rivers responded similarly to a normal dead-end filtration curve. The Umgeni River was noted to produce flux rates which were higher than those obtainable under normal dead-end. It can be concluded that there was no stabilisation of flux noted. However, feed water with low E.coli and turbidity concentrations enhances the flux rates. The technology was noted to produce water of less than 1 NTU and 100% removal efficiency for E.coli and total coliforms.

소규모 고도 수처리 기술 -가정용 정수시스템 중심으로-

  • Sung, Kyung-Hak;Cho, Bong-Yeon;Park, Ho-Wan
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.207-231
    • /
    • 1997
  • The use household water purifier is continuously increasing due to the distrust of the piped, rap water, which may be caused by the deterioration of water quality and water supply facilities in Korea. The water purifier distributing in the domestic market is the membrane type that composes of membrane as a basic filter, sediment filter as a prefilter and activated carbon filter instead of one purifying water system. The membrane type using as a water cleaning system is mainly the method of micro filtration(NIF) as well as ultra filtration(UF) and reverse osmosis(RO). The types of MF and UF are using to remove suspended solids and virus, and RO is using to remove ionic compound in chemical organic compounds. At the beginning the household water purifier was imported as end-product or assembled by only importing module from small businesses in Korea. Therefore, people was hard to confide in the product quality because the sales policy and management of water purifier by small business were not effectively organized. However, the defects of water purifier having up to now ate improving by the efforts of special branches of water purifier and large enterprises, and new great products are developing and producing. To develop the best quality product of water purifier in Korea, it should be considered seasonal water characteristrics rather than any other condition. For example, the water purifier can be affected by the water temperature change, increase of suspended solids in the rainy season and inflow of raw water having concentration in a dry season. The subject we have to investigate in the future is to develop the water purifying system adaptable in Korea which can treat the water quality using close analyses of local and seasonal water characteristics.

  • PDF

Monitoring of the Treatment of Leachate by Two Phase Anaerobic Membrane Process (TPAMP) (이상 혐기성 막공정에 의한 침출수 처리 모니터링)

  • Hwang, Moon H.;Hyun, Seong H.;Jang, Nam J.;Cho, Jea W.;Kim, In S.
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 2002
  • Landfill leachate is one of highly contaminated and heterogeneous wastewater. The leachate from initial landfill can be treated by anaerobic process because it contains biodegradable matters, particularly, volatile fatty acids (VFAs). However, the anaerobic treatment of leachate is generally required longer hydraulic retention time (HRT) than aerobic process and another treatment process to satisfy effluent concentration. Therefore the modification of conventional anaerobic treatment is needed. Two phase anaerobic membrane process (TPAMP) is an integrated membrane process to be able to separate anaerobic metabolism into two phase which are acidogenesis and methanogenesis for improvement of anaerobic treatment efficiency. In this study, the efficiency of TPAMP and conventional anaerobic treatment were compared in terms of HRT, effluent SCOD, VFAs Membrane used in TPAMP was the UF of capillary type with the surface area of $0.048m^2$. The average effluent SCOD of conventional anaerobic treatment was 1352 mg/L and the removal was 96 % at HRT 60 days, while in TPAMP, 927 mg/L and 98% at HRT 30 days.

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.