• Title/Summary/Keyword: Ulsan industrial complex

Search Result 117, Processing Time 0.031 seconds

Air Quality Prediction by CDMQC and Its Validation in the Ulsan Industrial Complex (CDMQC Model을 이용(利用)한 울산지역(蔚山地域)의 대기질(大氣質) 예측(豫測)과 실측치(實測値)와의 비교연구(比較研究))

  • Shin, Eung Bai;Lee, Kwang Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.77-90
    • /
    • 1981
  • This study involves 1) air quality disperson predictions and 2) a comparison of the predicted data with the actually measured ones in terms of annual sulfur dioxide concentration in the Ulsan Industial Complex. The prediction was made by utilizing the CDMQC air quality simulation computer model. The higher concentrations were observed at the Bugok Dong (Sampling Site) and the Yeochun Dong Sampling Site with the values of 44 and 46 ppb, respectively whereas the predicted values for both sites were 52 and 47 ppb, respectively. A statistical examination has revealed that the level of confidence was 90.02% from the Chi-squared test and the corelation coefficient was 0.827. It thus demonstrates that the model used for the study appears to be applicable to yield reliable predictions in terms of annual sulfur dioxide concentrations in the study area.

  • PDF

A Consequence Analysis of the Mitigation Impact on Emergency Shut-off Valves for Accidents of Underground Pipelines (사고영향평가를 이용한 지하 매설 배관 사고 시 긴급차단밸브에 의한 피해 범위 감소에 관한 연구)

  • Park, Sang Bae;Lee, Chang Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.2
    • /
    • pp.28-34
    • /
    • 2019
  • A large number of underground pipelines in the Ulsan National Industrial Complex has been constructed to improve the productivity of chemical products and tackle transportation problems. Now, the total of 1,293km of underground pipelines around 62 companies has been installed and operated. Many of underground pipelines have been installed outside of factories. For a past three years, five gas leakage accidents have occurred and the emergency response took up to 8 hours or more. Due to these delay in accidents, second serious accidents might occur and lead to occur damages to adjacent residents. In this study, it is assumed that emergency valve systems are installed under a ground and the efficacy of these is verified. Consequence analysis program was employed to evaluate the mitigation impact of emergency valve systems. The results show that these valve systems are economical and their performances for a mitigation are excellent. The results indicate that the installation of emergency valve systems for underground pipelines should be urgently legislated and performed.

Health and environmental risk assesment of air pollutants in Gyeongju and its vicinities(I) (경주 주변지역 대기오염물질의 보건.환경 위해성 평가(I))

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Park, Tong-So;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3740-3747
    • /
    • 2009
  • To protect the citizens' health of Gyeongju and to secure basic data for the assessment of health and environmental risk, distribution characteristics of meteorological elements were investigated and numerical simulation of wind field using RAMS model was carried out. In addition, measurement and analysis of air pollutants, forecasting the behavior air pollutants using ISC-AEROMOD view, and health and environmental risk-influenced zones were defined through managing air polluting materials to prevent health damage and property damage. According to the survey results of air pollution in Gyeongju and surroundings, average annual concentration of air pollutants in Gyeongju was slightly lower than that in Pohang and Ulsan areas, but concentration of particulate matters and nitrogen dioxide at Gyeongju Station Square and Yonggang Crossing were sometimes higher than that in Pohang and Ulsan areas. Results of the modeling of moving and diffusion of air pollutants that affect citizens' health showed that parts of the 1st through 4th industrial complexes together with POSCO were included in particulate matters and sulfur dioxide influenced areas in Pohang Steel Complex area, and that Haedo-dong, Sangdae-dong, Jecheol-dong and Jangheung-dong in Pohangnam-gu represented locally worsened air quality due to a quantity of air pollutant emission from dense steel industries and large scale industrial facilities.

Analysis of the Relative Efficiency and Competitiveness of Production Structure for the Industrial Clusters in Korea (국내 주요 산영클러스더별 상대적 효율성 분석 및 생산구조 비교)

  • Park, Chu-Hwan
    • Journal of the Korean Academic Society of Industrial Cluster
    • /
    • v.2 no.1
    • /
    • pp.44-60
    • /
    • 2008
  • This paper analyses the relative efficiency and competitiveness of production structure for the industrial clusters(Ulsan, Changwon, Kumi, Wonjoo, Banwol & Siwha, Kwangwju, Gunsan) which had allocated in 2004 in Korea by the DEA approaches. The results show that except U1san, Wonjoo, the 5 industrial clusters have improved the relative efficiency in terms of input and output since they were allocated. And, the reason of the inefficiency for the 5 industrial clusters were not for the technical relationship but for the production scaling size. That is, by clustering for the industrial production firms, the economic effect came true throughout the production scaling size effects. Also, by the positioning approach for the production factors such as labor, capital, and R&D investment via production growth, the results show that Banwol & Siwha, Goomi clusters have effectively been managed, but Wonjoo, U1san and Gunsan are not.

  • PDF

Development of an Air Pollution Monitoring Network Design Method Based on Regional Representativeness and Pollution Damage Impact (地域代表性과 汚染被害를 考慮한 大氣汚染 測定網 配置技法의 開發에 關한 硏究)

  • 김태형;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.1
    • /
    • pp.47-54
    • /
    • 1987
  • A new method for designing air pollution monitoring newtork is presented in this study. In this method, the magnitudes and the correlation coefficients of predicted concentrations in each grid points are examined and the monitoring stations are assigned to those stations which cover the damage cost the most. This method was applied to the Ulsan-Onsan Industrial Complex. This method turned out to be much more efficient than the method of TM coordinates and the method of concentric circles prescribed in the Standard Methods for Pollution Measurement as well as the existing monitoring system established in the area. The 21 stations selected by the method of TM coordinates could cover only 64.4% of the damage cost in the area, the 16 stations by the method of concentric circles 72.1%, and the existing 21 stations 67.8%, while 11 stations were enough to cover 90% of the damage cost in the area with this method. It also was found that this method required only 24 stations to cover the entire area.

  • PDF

A Study on the Air Pollution Impact Analysis Using the Environmental Information Management System (環境情報管理 系(EIMS)를 이용한 대기오염 피해분석방법에 관한 연구)

  • 박종화;장영기
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.19-26
    • /
    • 1986
  • The degree of air pollution is usually presented in terms of concentration. But, in evaluating the environmental impacts or air pollution control policies, the concentration values need to be interpreted in terms of damage effects on property and human health. The damage effect varies with the types of pollution, subjects and land use pattern of an affected area. Therefore, this study is aimed at developing a method of analyzing effects of various types of air pollutions on surrounding environmental setting with the EIMS (Environmental Information Management System) developed for land suitability analysis. Using the method formulated in this study, the long- term effects of such pollutants as $SO_2$ and HF on types of vegetation and residents, and potential, short-term effects of HCl leak accidents from manufacturing facilities in Ulsan and Onsan Industrial complex are analyzed. The presentation of the damage effects of air pollution rather than the concentration of pollutants will be useful for the preparation of environmental impact statements, the formulation of environmental policies, and the development of land use plans in heavily industrialized areas.

  • PDF

An Analysis of Multidimensional Productivity for the Shipbuilding Performance (조선 성과 측정을 위한 다차원 생산성의 분석)

  • Kim, Yearnmin
    • Korean Management Science Review
    • /
    • v.34 no.2
    • /
    • pp.57-66
    • /
    • 2017
  • The purpose of this study is to analyze the multidimensional productivity of the shipbuilding performance and to explain the role of different factors, such as man-hour, dock period, number of building block, launching process rate, automatic welding percent, and drawing fault rate which are important production-related variables in most shipbuilding companies. The shipbuilding productivity is obtained using Data Envelopment Analysis (DEA) approach. Then, a Tobit model is considered to measure the influence of different factors on the measured productivity. The results reveal that this productivity measure can substitute a representative shipbuilding productivity index (CGT/man-hour) in shipbuilding industries. Also, this multidimensional productivity analysis using DEA and Tobit reveals complex relationships between production-related variables and CGT and sale.

Isolation and Characterization of Cyclohexanol-utilizing Bacteria (Cyclohexanol 이용성 세균의 분리 및 특성)

  • 김태강;이인구
    • Microbiology and Biotechnology Letters
    • /
    • v.27 no.2
    • /
    • pp.107-112
    • /
    • 1999
  • A bacterium, which can utilize cyclohexanol as a sole source of carbon and energy, was isolated from sludge in sewage of Ulsan Industrial Complex for Petrochemicals, Korea and identified as Rhodococcus sp. TK6. The growth conditions of the bacteria were investigated in cyclohexanol containing media. The bacteria utilized cyclohexanol, cyclohexanone, cyclohexane-1,2=diol, cyclopentanol, cyclopentanone, and $\varepsilon$-caprolactone but not cyclohexane, cyclohexane-1,2-dione, and cyclooctanone. The bacteria were able to utilize alcohols such as ethanol, 1-propanol, 1-butanol, 1-pentanol, 1-hexanol, 2-methyl-1-propanol, 3-methyl-1-butanol, 2-propanol, and 2-butanol as well as cyclohexanol, organic acids such as adipate, propionate, butyrate, valerate, n-caproate, and 6-hydroxycaproate, and aromatic compounds such as phenol, salicylate, p-hydroxbenzoate, and benzoate as a sole source of carbon and energy. Cyclohexanone as a degradation product of cyclohexanol by Rhodococcus sp. TK6 was determined with gas chromatography.

  • PDF

환경보전 정책에 관한 제 방법의 상대적 효율성 연구 - 판매가능한 배출허용권제도를 중심으로 -

  • Lee, Seon;No, Gong-Gyun;Lee, Jae-Geun
    • Environmental and Resource Economics Review
    • /
    • v.1 no.1
    • /
    • pp.115-149
    • /
    • 1991
  • In evaluating current environmental protection policy, economists often note that current regulations are more costly than necessary to meet environmental quality standards. While the a priori case can be made that current regulatory approaches entail higher-than-necessary costs to attain environmental standards, there is relatively little empirical evidence to support this claim in Korea. The purpose of this analysis is to supply some of the missing evidence by presenting the results of one study that assesses some of the potential savings associated with implementing economic, rather than command-and-control regulatory approaches to abate one type of air pollution in one region, in Korea, Specifically, the analysis examine the costs of meeting a long-term standard for TSP under the alternative control strategies for stationary sources of TSP in Ulsan Industrial Complex region. The alternative strategies that are considered are current command-and-control and various marketable permit designs. The analysis shows that the most efficient policy of emissions control is economic approaches, supporting results of previous empirical studies conducted in other countries.

  • PDF

Isolation of pseudomonas sp. S-47 and its degradation of 4-chlorobenzoic acid

  • Seo, Dong-In;Lim, Jai-Yun;Kim, Young-Chang;Min, Kyung-Hee;Kim, Chi-Kyung
    • Journal of Microbiology
    • /
    • v.35 no.3
    • /
    • pp.188-192
    • /
    • 1997
  • The strain of S-47 degrading 4-chlorobenzoic acid (4CBA) was isolated from Ulsan chemical industrial complex by enrichment cultivation with 1 mM 4CBA. The strain was Gram-negative rod and grew optimally at 30.deg.C and pH 7 under aerobic condition, so that the organism was identified as a species of Pseudomonas. Pseudomonas sp. S-47 degraded 4-chlorobenzoic acid to produce a yellow-colored meta-cleavage product, which was confirmed to be 5-chloro-2-hydroxymuconic semialdehyde (5C-2HMS) by UV-visible spectrophotometry. 5C-3HMS was proved trometry. This means that Pseudomonas sp. S-47 degraded 4CBA via 4-chlorocatechol to 5C-2HMS by meta-cleavage reaction and then to 5C-2HMA by 5C-2HMS dehydrogenase.

  • PDF