Development of an Air Pollution Monitoring Network Design Method Based on Regional Representativeness and Pollution Damage Impact

地域代表性과 汚染被害를 考慮한 大氣汚染 測定網 配置技法의 開發에 關한 硏究

  • 김태형 (서울대학교 환경대학원 부설 환경계획연구소) ;
  • 김정욱 (서울대학교 환경대학원 )
  • Published : 1987.05.01

Abstract

A new method for designing air pollution monitoring newtork is presented in this study. In this method, the magnitudes and the correlation coefficients of predicted concentrations in each grid points are examined and the monitoring stations are assigned to those stations which cover the damage cost the most. This method was applied to the Ulsan-Onsan Industrial Complex. This method turned out to be much more efficient than the method of TM coordinates and the method of concentric circles prescribed in the Standard Methods for Pollution Measurement as well as the existing monitoring system established in the area. The 21 stations selected by the method of TM coordinates could cover only 64.4% of the damage cost in the area, the 16 stations by the method of concentric circles 72.1%, and the existing 21 stations 67.8%, while 11 stations were enough to cover 90% of the damage cost in the area with this method. It also was found that this method required only 24 stations to cover the entire area.

Keywords

References

  1. 化學技術誌 大氣汚染の觀測 大平