• 제목/요약/키워드: UV Efficiency

검색결과 810건 처리시간 0.032초

표면형상 변화에 따른 염료감응 태양전지의 전기화학적 특성 (Electrochemical Properties of Dye-sensitized Solar Cells with Improving the Surface Structure)

  • ;;구할본
    • 한국전기전자재료학회논문지
    • /
    • 제25권2호
    • /
    • pp.153-158
    • /
    • 2012
  • We use UV(ultraviolet)-$O_3$ treatment to increase the surface area and porosity of $TiO_2$ films in dye-sensitized solar cells (DSSCs). After the UV-$O_3$ treatment, surface area and porosity of the $TiO_2$ films were increased, the increased porosity lead to amount of dye loading and solar conversion efficiency was improved. Field emission scanning electron microscopy images clearly showed that the nanocrystalline porosity of films were increased by UV-$O_3$ treatment. The Brunauer, Emmett, and Teller surface area of the $TiO_2$ films were increased from $0.71cm^2/g$ to $1.31cm^2/g$ by using UV-$O_3$ treatment for 20 min. Also, UV-$O_3$ treatment of $TiO_2$ films significantly enhanced their solar conversion efficiency. The efficiency of the films without treatment was 4.9%, and was increased to 5.6% by UV-$O_3$ treatment for 20 min. Therefore the process enhanced the solar conversion efficiency of DSSCs, and can be used to develop high sensitivity DSSCs.

광촉매/오존을 이용한 염색폐수처리에 관한 연구 (A Study on the Dye Wastewater Treatment Using TiO2 Photocatalyst/Ozonation)

  • 김창균;정호진;김종석
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.663-670
    • /
    • 2007
  • This study was performed to provide basic information for evaluating the efficiency and applicable extent of photocatalysis and ozonation for the treatment of dye wastewater. The treatability of dye wastewater by $UV/TiO_2$ and $UV/TiO_2/O_3$ advanced oxidation process (AOP) was investigated under various conditions. The experiments were conducted in a batch reactor of 50 liters equipped with twelve UV Lamps of 16W. In $UV/TiO_2$ AOP, the removal efficiency of TCODMn and Color increased to 58% and 67% respectively with increasing UV intensity. Also, The removal efficiency of TCODMn and Color increased to 97% and 99% respectively with increasing $H_2O_2$. Acid area was more efficient than neutral and alkalic areas in wastewater treatment, and pH 5 was the most effective and the treatment efficiency continually increased as the amount of photocatalyst was increased. When the photocatalyst was increased, TCODMn was removed faster than Color.

UV emission characteristics of Ne+$N_2$ gas-mixture discharges in AC Plasma Display Panel

  • Baek, Byung-Jong;Hong, Sang-Min;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.586-589
    • /
    • 2002
  • The Ultra Violet(UV) emission characteristics of Neon + Nitrogen gas-mixture discharge was investigated in AC plasma display panel. The firing voltage of Ne+$N_2$ gas-mixture discharge increased with increasing nitrogen concentration. The UV intensity emitted from the gas discharge also increased with increasing nitrogen concentration. The UV efficiency increase with increasing $N_2$ partial pressure at low $N_2$ concentration, and then UV efficiency is saturated at high $N_2$ concentration.

  • PDF

Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구 (Removal of taste and odor causing compounds in drinking water using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.

자외선 및 초음파 공정에 의한 수용액 상의 PCBs 분해 (Removal of PCBs in Aqueous Phase in Ultraviolet (UV), Ultrasonic (US), and UV/US Processes)

  • 이덕영;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권4호
    • /
    • pp.1-7
    • /
    • 2021
  • The removal of PCBs (Polychlorinated biphenyls) in aqueous phase was investigated in the ultraviolet (UV) process, ultrasonics (US) process and ultraviolet/ultrasonic (UV/US) process using PCB No.7 and Aroclor 1260. For PCB No.7 relatively high removal efficiency over 90% was obtained during 20 min in the UV process and UV/US process. On the other hand, lower removal efficiency of 50 - 70% was achieved for it consisted of individual congeners of PCBs containing 3~8 of chlorine atom. It was found that the dechlorination reaction (the photolytic cleavage of C-Cl bond) was considered as a main removal mechanism in the UV process while PCBs were removed by cavitation-induced radical reaction in the US process. No significant dechlorination occurred in the US process. Consequently, it was suggested that the UV process or UV/US process was applicable for the removal of PCBs in aqueous phase in terms of the removal efficiency and operation time. In addition, the application of saturating gas such as Ar and Air could be considered to control redox condition and enhance the severity of acoustic cavitation for the removal of PCBs.

ITO 표면 처리와 음전극 변화에 따른 OLEDs의 특성 연구 (Study on Characteristic by ITO Surface Treatment and Cathode Change of Organic Light Emitting Diodes)

  • 김두석;장윤기;권영수
    • 한국전기전자재료학회논문지
    • /
    • 제18권12호
    • /
    • pp.1143-1147
    • /
    • 2005
  • In this study, we report an improved efficiency of Organic light emitting diodes(OLEDs), using $UV/O_3$ treated anode and different cathode. We investigated the efficiency of OLEDs by $UV/O_3$ treatment of ITO surface. We Performed $UV/O_3$ treatment and found that $UV/O_3$ treatment enhanced the performance of OLEDs. The fundamental structure of the OLEDs was ITO $anode/{\alpha}-NPD/Alq_3/Al$ or Li:Al cathode. The Li:Al can improve the OLEDs efficiency dramatically in cathode because it has lower work function than Al. Current-voltage, Luminance-voltage characteristics and luminance efficiency were measured at room temperature.

Photo-Fenton 공정과 UV/$H_2O_2$ 공정을 이용한 Lindane의 분해특성 비교 연구 (A Study on the degradation of Lindane in water by a Photo-Fenton process and a UV/$H_2O_2$ process)

  • 이주현;최혜민;김일규
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.109-117
    • /
    • 2010
  • In the present study, the degradation characteristics of Lindane by Advanced Oxidation Processes(UV/$H_2O_2$, Photo-Fenton process) were studied. The degradation efficiency of Lindane in aqueous solution was investigated at various initial pH values, Fenton's reagent concentrations and initial concentrations of Lindane. GC-ECD was used to analyze lindane. Lindane has not been degraded without application of AOPs over two hours. But, approximately 5% of lindane was degraded with UV or $H_2O_2$ alone. Lindane with UV/$H_2O_2$ process showed approximately 7% higher removal efficiency than $H_2O_2$ process. In the UV/$H_2O_2$ process, the pH values did not affect the removal efficiency. The optimal mole ratio of $H_2O_2/Fe^{2+}$ for lindane degradation is about 1.0 in Photo-Fenton process. Also, the experimental results showed that lindane removal efficiency increased with the decrease of initial concentration of lindane. Under the same conditions, the order lindane of removal efficiency is as following : Photo-Fenton process > UV/$H_2O_2$ process > $H_2O_2$ process. In addition, intermediate products were identified by GC-MS techniques. Than PCCH(Pentachlorocyclohexene) was identified as a reaction intermediate of the Photo-Fenton process.

실제 혼합염색폐수의 유동상 시스템을 활용한 미생물처리와 하이브리드 재순환시스템처리 (Treatment of an Authentic Textile-dyeing Wastewater Utilizing a Fluidized Biofilter and Hybrid Recirculating System Composed of the Fluidized Biofilter and a UV/photocatalytic Reactor)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제53권1호
    • /
    • pp.71-77
    • /
    • 2015
  • D염색공단의 폴리에스테르 알카리 감량폐수가 혼합된 실제 혼합염색폐수를 처리하기 위하여 Pseudomonas sp. 및 Bacillus cereus/thuringiensis를 고정한 폐타이어담체를 충전한 유동상 바이오필터를 운전하였다. 또한 유동상 바이오필터와 450 W의 UV/광촉매반응기를 결합한 하이브리드 재순환시스템을 구축하여 stage I에서는 UV/광촉매반응기를 바이패스하고 유동상 바이오필터만을, stage II-i, ii, iii에서는 하이브리드 재순환시스템을 각각 운전하였다. 유동상 바이오필터만을 사용하였을 경우에 $COD_{Cr}$ 및 색도 제거효율은 각각 75~80% 및 67%를 나타내었다. 한편 하이브리드 재순환시스템 운전에서 stage I에서 stage II-i로 전환되었을 때에 UV/광촉매산화공정의 $COD_{Cr}$ 제거율이 20~30%에 달하여 총 $COD_{Cr}$ 제거율은 75%로부터 80~85%까지 제고되었다. 한편 stage I에서 stage II-i로 전환되었을 때에 UV/광촉매산화공정의 색도제거율은 0~5%에 불과하였으나 총 색도제거율은 45~65%로부터 65~70%까지 제고되었다. 색도 제거에서는 $COD_{Cr}$ 제거와 다르게 UV/광촉매산화공정에 의하여 유동상 바이오필터의 효율이 제고되어서 하이브리드 재순환시스템의 시너지효과가 나타났다. 또한 색도제거에서는 $COD_{Cr}$ 제거와 다르게 반송비 증가에 따른 광촉매 비활성화가 관찰되지 않았고, $COD_{Cr}$ 제거에서 반송비 증가에 따른 광촉매 비활성화는 비가역적으로 관찰되었다.

UV/TiO2/H2O2를 이용한 축산폐수처리에 대한 연구 (A Study on the Swine Wastewater Treatment Using UV/TiO2/H2O2)

  • 김창균;정호진
    • 대한토목학회논문집
    • /
    • 제26권3B호
    • /
    • pp.321-327
    • /
    • 2006
  • 본 연구는 축산폐수처리를 위해 광촉매의 적용가능성과 처리효율 및 범위를 실험하여 축산폐수처리에 대한 기초 자료로 제시하고자 한다. 축산폐수처리에 대한 광촉매양의 증가는 높은 처리효율을 나타냈으며 알카리 영역에서 보다 산성영역 특히 pH3에서 축산폐수처리 효과는 우수하게 나타났다. 또한 광촉매양의 증가에 따라 색도 보다는 $TCOD_{Mn}$의 제거가 빠르게 이루어 졌다. UV 또는 $TiO_2$를 단독으로 사용하여 폐수처리를 하였을 때 보다 $UV/TiO_2$를 함께 적용하였을 때가 처리효율은 우수하게 나타났으며 산화제로 과산화수소를 주입하였을 때 처리효율은 $UV/TiO_2$만을 적용하였을 때 보다 처리효율이 우수하게 나타났다. 본 실험에서의 과산화수소 적정 주입량은 200 mg/L이며 과산화수소 적정주입량이 보다 많이 주입되었을 때는 처리효율이 떨어지는 것으로 나타났다. 또한 과산화수소의 주입량은 실험 시 계속적으로 주입이 되어야 높은 처리효율을 얻을 수 있었다.

전해 염소수/자외선 결합 시스템을 이용한 병원성 미생물의 불활성화 키네틱스 평가 (Evaluation of inactivation kinetics on pathogenic microorganisms by free chlorine/UV hybrid disinfection system)

  • 서영석;김애린;조민
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.379-388
    • /
    • 2019
  • Chlorination and UV illumination are being widely applied to inactivate a number of pathogenic microbials in the environment. Here, we evaluated the inactivation efficiency of individual and combined treatments of chlorination and UV under various aqueous conditions. UV dosage was required higher in waste water than in phosphate buffer to achieve the similar disinfecting efficiency. Free chlorine generated by electrolysis of waste water was abundant enough to inactivate microbials. Based on these, hybrid system composed of sequential treatment of electrolysis-mediated chlorination and UV treatment was developed under waste water conditions. Compared to individual treatments, hybrid system inactivated bacteria (i.e., E. coli and S. typhimurium) and viruses (i.e., MS-2 bacteriophage, rotavirus, and norovirus) more efficiently. The hybrid system also mitigated the photo re-pair of UV-driven DNA damages of target bacteria. The combined results suggested the hybrid system would achieve high inactivation efficiency and safety on various pathogenic microbials in wastewater.