• Title/Summary/Keyword: UV 센서

Search Result 188, Processing Time 0.022 seconds

Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor (UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

Radiation Effects on Fiber Bragg Grating Sensors Written in UV KrF Laser Process Condition (UV KrF 레이저 공정조건에 따른 FBG 센서의 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.161-166
    • /
    • 2016
  • We studied the effect of $Co^{60}$ gamma-radiation on the FBGs by a variation of grating the fabrication parameters. The FBGs were fabricated in a different UV KrF laser intensity using the same boron co-doped photo-sensitive fiber and exposed to gamma-radiation up to a dose of 33.8 kGy. According to the experimental data and analysis results, We confirmed that the laser intensity for grating inscription has a highly effect on the radiation sensitivity of the FBGs and the radiation-induced Bragg wavelength shift by the change of laser process condition showed a difference more than about 30 %.

Dy co-doping effect on photo-induced current properties of Eu-doped SrAl2O4 phosphor (Eu 도핑 SrAl2O4 형광체의 광 여기 전류 특성에 대한 Dy 코-도핑 효과)

  • Kim, Sei-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.48-53
    • /
    • 2009
  • $Eu^{2+}$-doped ${SrAl_2}{O_4}$ and $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors have been synthesized by conventional solid state method. Photocurrent properties of $Eu^{2+}$ doped ${SrAl_2}{O_4}$ and $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors, in order to elucidate $Dy^{3+}$ co-doping effect, during and after ceasing ultraviolet-ray (UV) irradiation have been investigated. The photocurrent of $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors during UV irradiation was 4-times lower than that of $Eu^{2+}$-doped ${SrAl_2}{O_4}$ during UV irradiation, and 7-times higher than that of $Eu^{2+}$-doped ${SrAl_2}{O_4}$ after ceasing UV irradiation. The photocurrent results indicated that holes of charge carriers captured in hole trapping center during the UV irradiation and liberated after-glow process, and made clear that $Dy^{3+}$ of co-dopant acted as a hole trap. The photocurrent of ${SrAl_2}{O_4}$ showed a good proportional relationship to UV intensity in the range of $1{\sim}5mW/cm^2$, and $Eu^{2+}$-doped ${SrAl_2}{O_4}$ was confirmed to be a possible UV sensor.

Annealing effects of ZnO:Er films on UV emission (ZnO:Er막의 UV 발광에 미치는 열처리 효과)

  • Choi, Mu-Hee;Ma, Tae-Young
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.316-321
    • /
    • 2009
  • Er-doped ZnO(ZnO:Er) films were deposited onto MgO wafers by ultrasonic spray pyrolysis at 550 $^{\circ}C$ varying the concentration of Er in the deposition source from 0.5 wt% to 3.0 wt%. Annealing of the films in a vacuum was carried out to increase the intensity of ultraviolet(UV) emission from the films. The annealing temperature was between 600$^{\circ}C$ and 800$^{\circ}C$. The crystallographic properties and surface morphology of the films were investigated by X-ray diffraction(XRD)and scanning electron microscope(SEM), respectively. The properties of photoluminescence(PL) for the films were investigated by the dependence of PL spectra on the annealing temperature. X-ray photoelectron spectroscopy(XPS) was conducted to find the composition change in the films by the annealing.

UV Detecting according to Corona Discharge Intensity using UV Sensor (자외선 센서를 이용한 코로나 방전 강도에 따른 자외선 검출)

  • Kwag, Dong-Soon;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.78-83
    • /
    • 2014
  • To minimize the financial loss due to power facility malfunction, on-line diagnostic techniques are required to grasp any abnormal state of facilities in the live line as well as devices to diagnose abnormal states of power facility in an easy and prompt manner. This study aims to develop a portable UV detecting system by means of UV sensors for easier and efficient inspection of the degradation state of power facility in a long distance. Accordingly, it includes a simulation of corona discharges that may occur due to degradation of power facility and detection of ultraviolet pulse generation depending on the corona discharge intensity and measuring distance in application of UV sensors. Additionally, the optimal algorithm is determined for its application to the system's degradation diagnosis program based on the measured experiment data.

Improvement of Sensitivity in Porous Silicon Alcohol Gas Sensors by UV Light (자외선조사에 의한 다공질 실리콘 알코올 센서의 감도 개선)

  • Kim, Seong-Jin;Choe, Bok-Gil
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.676-680
    • /
    • 1999
  • To do breath alcohol measurement, a sensor is necessary that it can detect low alcohol gas concentration of 0.01% at least. In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to measure low alcohol gas concentration. The sensor using porous silicon layer has some sensitivity at room temperature by very large effective surface area, but there is still much room for improvement. In this experiment, we measured the capacitance of the sensor under 254 nm UV light on the porous silicon layer, in which alcohol solution was kept in a flask at 25, 35, and $45^{\circ}C$ by a heater. As the result, the improvement of sensitivity by illuminating UV light was observed. The increasing rate of the capacitance was shown to be double more than those measured under UV-off state. It is supposed that UV light activates response of the oriental and interfacial polarizations which have slow relaxation time for AC field.

  • PDF

A Study on the Multi-sensor Toilet (다중센서 양변기에 관한 연구)

  • Lim, Jeong-Been;Park, Nam-Ki;Choi, Bo-Gyeom;Kim, Yeon-Koung;Kim, Jae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.201-206
    • /
    • 2022
  • In this paper, a flushing system with automatic opening and closing function of the toilet cover was studied. It works by an infrared sensor attached to the cover is detected or not. When the infrared sensor of the open function detects it, the servomotor is driven on the toilet cover to raise the cover, and when the infrared sensor with the close function detects the infrared sensor, the cover is set to be lowered. A tilt sensor is attached to the inside of the cover to operate when the cover goes down, and when this is activated, the servomotor connected to the toilet lever opens the stopper of the supply port and sends water down. In addition, we minimized the inconveniences for the next user when they use the toilet by using the non-contact water level sensor and LED function to notice the water is clogged during the flushing process. Also, we implemented UV-LED function to prevent bacterial growth while the toilet is closed.

The contactless elevator button using the electrostatic capacity (정전 용량을 이용한 비접촉식 엘리베이터 버튼)

  • Bang, Gul-Won
    • Journal of Industrial Convergence
    • /
    • v.19 no.6
    • /
    • pp.67-72
    • /
    • 2021
  • The elevator installed in the building consists of an elevator call button and an input button for selection to the target floor. The elevator button is input only when the elevator user directly presses it. Such passenger input can be infected with an infectious disease due to contamination of the button. A non-contact button is required as a means for solving this problem, which detects the proximity of an object by applying a capacitive method. It implements a function of measuring the body's body temperature by attaching an infrared heat sensor, and provides a sterilization function of a button by attaching a UV-LED. A button was selected, a body temperature was measured through an infrared temperature measurement sensor, and UV-LED was turned on and sterilized when there was no user. The contactless elevator button is expected to be effective in preventing infectious diseases as it can prevent infection of viruses carrying infectious diseases and can detect body temperature to select positive patients of CIVID 19.