• Title/Summary/Keyword: UV 검출기

Search Result 106, Processing Time 0.024 seconds

Implementation of a Real-time SIFT Pitch Detector (실시간 SIFT 기본주파수 검출기의 구현)

  • Lee, Jong Seok;Lee, Sang Uk
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.101-113
    • /
    • 1986
  • In this paper, a real-time pitch detector LPC vocoder as implemented on a high speed digital signal processor, NEC 7720, is described. The pitch detector was based mainly on the SIFT algorithm. The SIFT pitch detector consists primarily of a digital low pass filter, inverse filter, computation of autocorrelation, a peak picker, interpolation, V/UV defcision and a final pitch smoother. In our approach, modification, mainly on the V/UV decision and a final pitch smoother, was made to estimate more accurate pitches. An 16-bit fixed-point aithmatic was employed for all necessary computation and the simulated results were compared with the eye detected pitches obtained from real speech data. The pitch detector occupies 98.8% of the instruction ROM, 37% of the data ROM, and 94% of internal RAM and takes 15.2ms to estimate a pitch when an analysis frame is consisted of 128 sampled speech data. It is observed that the tested results were well agreed with the computer simulation results.

  • PDF

A Study on the Real-Time Oil-Spill Monitoring Technology (실시간 기름유출 모니터링 기술에 관한 연구)

  • Yeom, Woo-jung;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.472-477
    • /
    • 2017
  • Oil spills cause a lot of damage to the environment. Oil destroys the water environment and ecosystem in a very short period of time once they are contaminated by it, it takes a lot of time to recover from the contamination and the cleaning process is very difficult. Therefore, oil detectors are greatly needed as they can monitor any oil spills over the sea, rivers, and lakes. There are two kinds of technology available for detecting oil, viz. the contact and non-contact types. The former is based on the use of the conductivity, capacitance and microwaves, while the latter employs infrared, UV, laser, optic and radar technologies. As there are also various hurdles in the measuring of oil on water, such as the presence of waves, refraction of light, temperature and saltiness, it is imperative to select the right oil detector which is appropriate for the specific environment. In this study, a contact type oil detector is developed, which can be used in oil related industries, such as refineries, petrochemical companies, and power generation stations. The detector is made up of the sensor module, which floats on the water, and the controller which processes the signal coming from the sensor module and displays it. It is designed in such a way that the existence of oil is detected through the sensor and the change in the permittivity is observed to determine the volume and type of spilled oil.

Simulation of Target Detection using UV and IR Band Signals (UV와 IR 대역 신호를 이용한 표적 신호 검출 시뮬레이션)

  • Du, Gyeong-Su;O, Jeong-Su;Jang, Seong-Gap;Hong, Hyeon-Gi;Seo, Dong-Seon;Choe, Jong-Su
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.1
    • /
    • pp.79-88
    • /
    • 2001
  • The target such as aircraft operates flares to protect itself from the missile. In general, Infra-red(IR) flares that are hot bodies radiating energy considerably greater than it does, so cause the missile to guide the flare instead of the target. For a precise target tracking in spite of a presence of flares, therefore, the seeker should discriminate the target signal from various clutters including the flare and the background. In this paper, we simulated 2-color rosette scan seeker using IR and UV(UltraViolet) bands. In each wave band, we analyzed the radiant distributions of the target, the flare, and background. These results showed that a simultaneous process in two bands can detect precisely the target.

  • PDF

A Study on the Simultaneous Analysis of Fat-Soluble Vitamins in Food Stuffs and Vitamin Products by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 식품 및 비타민 제제중의 지용성 비타민의 동시 분석에 관한 연구)

  • Poongzag Kim;Chong-Hyeak Kim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.46-54
    • /
    • 1989
  • The extraction method and quantitative analysis for the fat-soluble vitamins present in food stuffs and vitamin products have been investigated. The simultaneous separation and analysis of the vitamins by reverse phase high performance liquid chromatographic method was conducted using an isocratic elution with methanol : water (95 : 5) eluent on a Novapak $C_{18}$ column. The detection of vitamins was achieved by a variable wavelength UV detector. To improve the detection sensitivity detection wavelengths were set at the highest absorption bands such as 330, 265, 285, and 290nm for the respective vitamins. The analysis for the fat-soluble vitamins was finished within 40 minutes. Alkaline hydrolysis and enzymatic hydrolysis were investigated for the sample preparation; and liquid-liquid extraction and liquid-solid extraction were attempted for the extraction of vitamins. Both hydrolysis methods were turned out to be appropriate for the analysis for vitamins A, D, and E, while for the analysis of vitamin K the enzymatic hydrolysis method demonstrated better results. Diethyl ether, pentane, and n-hexane were found to give higher recovery for the liquid-liquid extraction and silica cartridge for the liquid-solid extraction.

  • PDF

Determination of Oxolinic Acid Residues in Acetes japonicus by HPLC (보리새우에 잔류하는 Oxolinic Acid HPLC를 이용한 검출법)

  • 이문한;임재영;정순관;손성완;박종명
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.3
    • /
    • pp.147-150
    • /
    • 1993
  • A novel rapid and sensitive method to detennine residual oxolinic acid in Acetes japonicus was developed. The residual oxolinic acid was extracted with ethylacetate and diluted oxalic acid, and interfering substances were removed by hexane. Fifty ppb residual concentration in the extract could be quantitated by UV-HPLC and the recovery rates were 79-91% according to the fortified amounts.

  • PDF

A Study on the Determination of Caffeine in Coffee, Black tea and Green Tea by high performance Liquid Chromatography (고속액체 크로마토크래피에 의한 커피, 홍차, 녹차중의 카페인 정량에 관한 연구)

  • 권익부;이윤수;우상규;이충영;서준걸
    • Journal of Food Hygiene and Safety
    • /
    • v.5 no.4
    • /
    • pp.213-217
    • /
    • 1990
  • A simple and practical method for the determination of caffeine in coffee, black tea and green tea was studied. The analysis of caffeine was performed by reverse phase high perfomance liquid chromatography using a ${\mu}-Bondapak$ C18 column at isocratic condition with methanol-acetic acid-water (20: 1: 79) on UV detector at 280 nm. The extraction and clean-up of caffeine in sample is based on combing a simple pretreatment with the use of a Sep-Pak Alumina A cartridge. The average recoveries of caffeine from several samples were 95.2 -101.3%, the relative standard deviation for the whole procedure was 0.10 ~ 0.62%, and the detection limit of caffeine in sample solution was about $0.1\;\mu\textrm{g}\;per\;ml$.

  • PDF

Studies on the Separation and Discrimination of the Natural Yellow Pigment on Croaker (참조기 천연색소의 분리 및 판별법에 관한 연구)

  • Kim, Hee-Yun;Hong, Ki-Hyung;Hong, Jin-Hwan;Kim, Dong-Sul;Han, Sang-Bae;Lee, Eun-Ju;Lee, Jeung-Seung;Kang, Kil-Jin;Chung, Hyung-Wook;Song, Kyung-Hee;Park, Jong-Seok;Kwon, Yong-Kwan;Jang, Young-Mi;Shin, Il-Shik;Lee, Chang-Kook;Park, Hee-Yul;Ha, Sang-Chul;Jo, Jae-Sun;Park, Hye-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.762-769
    • /
    • 2002
  • As a preliminary test for defining intact yellow croaker pigment, the pigment was analyzed by column chromatography and UV-vis spectrophotometry. All maximum absorbance wavelengths commonly showed three maximum absorbance ranges, similar to those of carotenoid, suggesting that the tested pigment may be carotenoid. We detected total six peak RT values in the chromatogram through PDA-HPLC under gradient mode (behavior A at 10% for initial 2 min and changed to behavior B for 60 min). Most pigments were detected at the peak with 3.27 RT value. Because seven peaks were detected under gradient mode and three under isocratic mode [methanol : methylene chloride (90 : 10, v/v)], gradient mode was determined to be more appropriate for quantitative analysis. By the comparison test of RT values among yellow pigment in croakers and reference pigments, such as zeaxanthine, ${\beta}-cryptoxanthine$, ${\beta}-carotene$, and astaxanthin, only ${\beta}-cryptoxanthine$ was detected in the white croaker, whereas such pigment of yellow croaker having RT value of 31.02 was not detected. Therefore, RT value was found to be applicable for detecting adulterated croaker.

Measurement of Atmospheric Trace Gases and Atmospheric Extinction with a UV-VIS spectrometer system (분광기를 이용한 대기중의 가스 측정과 대기 광 감쇄도 측정)

  • 이정순;이철규;김은영;김영준
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.210-211
    • /
    • 2003
  • 대기 환경에 있어서 인간에 위해한 기준 가스들을 측정하는 방법은 여러 가지가 있다. 근래에 이르러 이들을 측정 관리하기 위하여 분광학적인 방법을 이용하는 시도가 늘어나고 있다. 유럽에서 널리 이용중인 차등 흡수 분광기(Differential Optical Absorption Spectrometer)는 현재는 위성에 응용되어 운용되고 있으며 가스의 전자 떨림이나 회전에 의한 에너지 흡수선을 이용하여 해당가스를 검출해내는 기술을 그 원리로 하고 있다. (중략)

  • PDF

Determination of Trace Iodide in Sodium Bisulfite Aqueous Solution by Ion Chromatography with UV Detection (이온크로마토그래피를 이용한 Sodium bisulfite 수용액 중의 미량 요오드 정량)

  • Park, Yang-Soon;Kim, Do-Yang;Choi, Kwang-Soon;Park, Soon-Dal;Han, Sun-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.304-308
    • /
    • 2000
  • The iodide was recovered from a simulated spent fuel to the sodium bisulfite aqueous solution. It was discussed that the trace iodide (below 1 ppm) was determined without the matrix effect of 0.1 M sodium bisulfite and 1 mM $HNO_3$ in aqueous solution by ion chromatography with UV detection. AS4A-SC (DIONEX) column and UV-absorption spectrophotometer were used. The UV-absorption spectra of sodium bisulfite, nitric acid and iodide were obtained, and then 230 nm was selected as an absorption wavelength for iodide determination. 0.1 M NaCl eluent was optimum condition. In this condition the calibration curve of iodide was obtained on the range of about 0-1,000 ppb. The linear coefficient was 0.99993 and the detection limit was 5 ppb. The relative standard deviation was 1.26%.

  • PDF

A Study on Ultrasonic Transducer displacement generator by Frequency Phase modulation (주파수 위상 변조에 의한 초음파 탐촉자 변위 발생기에 관한 연구)

  • 김정래
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.3
    • /
    • pp.36-41
    • /
    • 2002
  • This study was carried out develope a ultrasonic transducer displacement generator through 26KHz and 38KHz of the frequency phase modulation on the ultrasonic transducer. This system was producted a power output generation such as 100W, 300W, 400W and 600W. Ultrasonic power output had a change of time. We made use of a Thiram hydration and detected it measurement by the ACAO method. It was to decide the result of ultrasonic power supply for time duration and the result of comparison in the 26KHz & 38KHz by UV/VIS spectrophotometer.

  • PDF