• Title/Summary/Keyword: UV램프

Search Result 126, Processing Time 0.062 seconds

The Study of Ag Thin Film of Suitable Anode for T-OLED: Focused on Nanotribology Methode (UV 처리에 의한 T-OLED용 산화전극에 적합한 Ag 박막연구: Nano-Mechanics 특성 분석을 중심으로)

  • Lee, Kyu Young;Kim, Soo In;Kim, Joo Young;Kwon, Ku Eun;Kang, Yong Wook;Son, Ji Won;Jeon, Jin Woong;Kim, Min Chul;Lee, Chang Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.328-332
    • /
    • 2012
  • The work function of Ag (silver) is too low (~4.3 eV) to be used as an electrode of T-OLED (Top Emission Organic Light Emitting Diode). To solve this weakness, researches used plasma-, UV-, or thermal treatment on Ag films in order to increase the work function (~5.0 eV). So, most of studies have focused only on the work function of various treated Ag films, but studies focusing on nanomechanical properties were very important to investigate the efficiency and life time of T-OLED etc. In this paper, we focused on the mechanical properties of the Ag and $AgO_x$ film. The Ag was deposited on a glass substrate with the thickness of 150 nm by using rf-magnetron sputter with the power was fixed at 100 W and working pressure was 3 mTorr. The deposited Ag film was UV treated by UV lamp for several minutes (0~9 min). We measured the sheet resistance and mechanical property of the deposited film. From the experimental result, there were some differences of the sheet resistance and surface hardness of Ag thin film between short time (0~3 min) and long time UV treatment. These result presumed that the induced stress was taken place by the surface oxidation after UV treatment.

A Study of Liquid Chromatographic Detection Method for Thiocarbamates by Using Photochemical Reaction (광화학 반응을 이용한 티오카바메이트류의 액체 크로마토그래피 검출법에 관한 연구)

  • Dai Woon Lee;Young Hun Park;Yong Wook Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.4
    • /
    • pp.453-461
    • /
    • 1993
  • Detection method was developed using a simply designed photochemical reactor made of teflon coil and low pressure mercury lamp. This method of UV photolysis of analytes followed by UV, fluorescence and electrochemical detection was found to be useful for four thiocarbamates. Analytes eluting from the column are irradiated with a high flux of 254 nm UV light, so that they change to either fluorescent active forms or highly electrochemically sensitive products. Appling this technique to the UV detection, thiocarbamates were converted into long wavelength absorbing products upon UV irradiation. In fluorescence detector four thiocarbamates are not detected at nonirradiated condition but fluorescence signals of MPTC, CPTC photolysates are appeared after irradiation with UV light. The electrochemical detection for the determination of thiocarbamates was enhanced up to 5∼20 fold signal after UV irradiation, compared to that of the nonirradiated. The detection limit of thiocarbamates on electrochemical detector was 13.3∼0.02 ng under pH 7.0, ionic strength $0.5{\times}10^{-2}$ M, phosphate buffer solution. Adducts produced by reaction of photolysates and OPA-MERC in the reaction coil were monitored at 425 nm with fluorescence detector, and one of the photolysates was primary amine.

  • PDF

A Study on the Operational Variables of the UV-TiO$_2$ Based Photocatalytic Air Cleaning System (UV-TiO$_2$ 광촉매 기반의 공기 정화 시스템의 운전조건에 대한 연구)

  • Han, Chang-Seok;Chang, Hyuk-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.293-301
    • /
    • 2008
  • A study on the operational variables of the UV-TiO$_2$ based photocatalytic air cleaning system was tried. In this study, to examine effects as various air cleaning system conditions, a duct-type reactor was made, and TiO$_2$ was immobilized on a stainless mesh. Benzene was chosen as a target compound. Removal experiments for benzene were done under different initial benzene concentration, air velocity, TiO$_2$ loading, area coated TiO$_2$ as the same TiO$_2$ loading, and UV light intensity conditions. During the experiments, relative humidity was 55%, and reactor temperature was 45$^{\circ}C$. As a result, the photocatalytic degradation of benzene decreased as the inlet concentration increased. But the photocatalytic degradation increased as the concentration boundary layer thickness, amount of TiO$_2$, area coated TiO$_2$ as the same amount of TiO$_2$, and UV light intensity increased. Based on results of current study, they can be applied to the design of air cleaning system over low level VOCs in the indoor air.

UV 처리에 의해 표면 산화 처리한 Silver Oxide 박막의 결정 변화에 따른 Nano Mechanics 특성 연구

  • Lee, Gyu-Yeong;Kim, Seong-Jun;Song, Ji-Eun;Kim, Su-In;Lee, Chang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.506-506
    • /
    • 2013
  • Ag (Silver) 박막은 낮은 전기 저항과 높은 가시광대의 반사율을 가져 T-OLED (Top Emission-Organic Light Emitting Diode)의 Anode로 각광 받고 있지만, 일반적인 Ag 박막의 일함수는 4.3 eV 이하로 T-OLED의 Anode로 사용하기에는 낮은 단점이 있다. 따라서 이를 극복하기 위한 방법으로 Ag 박막 표면을 산화시켜 일함수를 증가시키기 위한 연구가 진행중에 있다. 하지만 연구는 단순히 일함수를 증가시키는 것에 한정되어 있을 뿐 UV 처리된 박막의 nano-mechanics 특성에 대한 연구는 현재 전무하다. 따라서 본 연구에서는 순도 99.9%의 Ag 타겟을 이용하여 rf magnetron sputter 장비를 통해 Ag 박막을 증착 하였고, 이후 UV (Ultra-Violet) 램프를 통해 시료 표면을 산화시켰다. 특히, 이 논문의 주요 관심사인 박막의 nano mechanics 특성 분석을 위하여 nano indenter와 SPM (Scanning Probe microscope) 장치를 활용 하였다. 실험 결과 후처리 시간이 3분 이하인 경우 박막이 비결정질의 silver oxide로 성장하는 것을 확인하였으며, 이때 박막의 면저항은 $0.16{\Omega}$/sq.에서 $0.55{\Omega}$/sq.로 증가하는 것을 관찰할 수 있었고, 3분 이후, 비결정질의 silver oxide가 conducting 특성을 갖는 silver oxide 결정을 이루면서 면저항이 $0.55{\Omega}$/sq.에서 $0.21{\Omega}$/sq.로 감소하는 것을 보았다. 또한 결정질의 박막이 자라는 3분이상의 박막에서 surface hardness는 급격하게 증가($3.57{\rightarrow}9.47$ GPa)했으며, 6분 이후에는 감소하는($9.47{\rightarrow}3.46$ GPa) 경향을 보였다. 이러한 경향은 silver oxide의 결정 크기가 Ag 결정 보다 크므로 상대적인 압축응력을 받아 표면 경도가 증가됐다. 처리시간 6분 이후, 경도 감소는 박막의 표면 물성이 불안정해졌기 때문이다.

  • PDF

The Microwave-assisted Photocatalytic Degradation of Methylene Blue Solution Using TiO2 Balls Prepared by Chemical Vapor Deposition (CVD법으로 제조된 산화티탄 볼과 마이크로웨이브를 이용한 메틸렌블루 수용액의 광촉매분해)

  • Park, Sang-Sook;Park, Jae-Hyeon;Kim, Sun-Jae;Jung, Sang-Chul
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1063-1068
    • /
    • 2008
  • The photocatalytic degradation of methylene blue water solution was carried out by irradiating microwave and UV light simultaneously using $TiO_2$ photocatalyst balls prepared by Chemical Vapor Deposition method. A microwave-discharged electrodeless UV lamp was developed to use microwave and UV simultaneously for photocatalytic reactions. The results of photocatalytic degradation of methylene blue showed that the decomposition rate increased with the microwave intensity, the circulating fluid velocity and auxiliary oxidizing agents added. Especially, the rate constant of $H_2O_2$-added photocatalytic reaction increased about three times from $0.0061min^{-1}$ to $0.0197min^{-1}$ when microwave was additionally irradiated. This study demonstrates that the microwave irradiation can play a very important role in photocatalytic degradation using peroxides although it is not easy to quantitatively assess the effect of microwave on photocatalytic reactions from the experimental data of this study.

Photocatalytic Destruction of a Mordant Yellow-12 Using Rutile-$TiO_2$ (Rutile-$TiO_2$를 이용한 Mordant Yellow-12의 광촉매 분해반응)

  • Kim, Chang Suk;Choi, In Won
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.646-651
    • /
    • 2000
  • The photocatalytic degradation of Mordant Yellow-12 (MY-12) was investigated using a UV-Visible Spectrophotometer and pH meter. The UV-Visible absorbance spectra of the MY-12 contaminated water before and after treatment were presented in figure. The decrease of absorbance occurs at the range of 250 and 450 nm, this result suggests that photocatalytic degradation involves destruction of the aromatic rings in this experiment. More than 32% of the MY-12 was decomposed after one hour in 26-W fluorescent lamp, whereas it was 17% and 24% respectively in 15-W and 21-W lamps. MY-12 was decomposed completely after three hours in 26-W fluorescent lamp. The destruction rate constants were calculated from the change of absorbance and pH.

  • PDF

Degradation of MEK using continuous single module photo-catalytic reactor (연속식 광촉매반응기를 이용한 MEK 분해특성 연구)

  • Peng, Mei Mei;Cha, Wang Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5304-5309
    • /
    • 2013
  • The degradation of methylethylkeone(MEK) was investigated by the continuous single module photocatalytic reactor. Operational conditions were initial concentration of MEK, intensity of photon flux, and activity change according to the long time operation. The photocatalytic degradation was decreased with the increase of MEK concentration, and the degree of decrease was larger at higher flow rate. Removal efficiency of photocatalytic reactor was decreased with the increase of reactor diameter and lamp wavelength under the same residence time condition. Continuous single module photocatalytic reactor was successfully operated without any activity drop during 120hrs operation.

Determination of Photodegradation Rate Constant of LDPE (LDPE 광분해 반응의 속도 상수 결정)

  • Kim, Hyoun Joo;Jung, Il Hyun;Hong, In Kwon;Lee, Jae Dong
    • Applied Chemistry for Engineering
    • /
    • v.5 no.4
    • /
    • pp.637-645
    • /
    • 1994
  • The LDPE films were photolyzed for 100 hours in UV apparatus with 400-W medium pressure mercury lamp radiating wavelengths longer than 254nm. A simple kinetic model was introduced and was applied to interpret the FT-IR absorbance of carbonyl and hydroperoxide bonds as a function of UV exposure time. From these data, the reaction mechanism and the rate determining step of photodegradation were determined.

  • PDF

Degradation of Microcystin-LR, Taste and Odor, and Natural Organic Matter by UV-LED Based Advanced Oxidation Processes in Synthetic and Natural Water Source (UV-LED기반 고도산화공정을 이용한 수중 마이크로시스틴-LR, 이취미 물질, 자연유기물 분해)

  • Yang, Boram;Park, Jeong-Ann;Nam, Hye-Lim;Jung, Sung-Mok;Choi, Jae-Woo;Park, Hee-Deung;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.246-254
    • /
    • 2017
  • Microcystin-LR (MC-LR) is one of most abundant microcystins, and is derived from blue-green algae bloom. Advanced oxidation processes (AOPs) are effective process when high concentrations of MC-LR are released into a drinking water treatment system from surface water. In particular, UV-based AOPs such as UV, $UV/H_2O_2$, $UV/O_3$ and $UV/TiO_2$ have been studied for the removal of MC-LR. In this study, UV-LED was applied for the degradation of MC-LR because UV lamps have demonstrated some weaknesses, such as frequent replacements; that generate mercury waste and high heat loss. Degradation efficiencies of the MC-LR (initial conc. = $100{\mu}g/L$) were 30% and 95.9% using LED-L (280 nm, $0.024mW/cm^2$) and LED-H (280 nm, $2.18mW/cm^2$), respectively. Aromatic compounds of natural organic matter changed to aliphatic compounds under the LED-H irradiation by LC-OCD analysis. For application to raw water, the Nak-dong River was sampled during summer when blue-green algae were heavy bloom in 2016. The concentration of extracellular and total MC-LR, geosmin and 2-MIB slightly decreased by increasing the LED-L irradiation; however, the removal of MC-LR by UV-LED (${\lambda}=280nm$) was insufficient. Thus, advanced UV-LED technology or the addition of oxidants with UV-LED is required to obtain better degradation efficiency of MC-LR.

Effects of UV Sterilization on Quality of Acer mono Sap (자외선 살균이 고로쇠 수액의 품질에 미치는 영향)

  • Choe, Su Bin;Han, Sang Jin;Han, Ouk Hee;Kim, Hak Su;Kang, Sung Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.1
    • /
    • pp.148-152
    • /
    • 2013
  • An ultraviolet (UV) sterilization system was developed to decrease the number of microorganisms in filtered Acer mono sap (FAS). The Acer mono sap (AS) was passed through 18 strips of PTA fluoroplastic tubing with 30 UV lamps (total 1,170 W). During passage, the AS was effectively exposed to the UV rays. The total bacteria, coliform group and fungi were sterilized at a flow rate ranging from 852 to 1,358 mL/min and a UV power higher than 156 W. Although the sensory score of the UV-sterilized AS was significantly lower than that of the untreated AS, the sensory score was better under the condition of 390 W and 852~1,358 mL/min than under the other conditions examined. ANOVA did not reveal a significant difference in pH, total acidity, sugar content and color characteristic under all conditions tested (p<0.05). Considering the overall attributes of the AS quality, the optimum sterilization condition was determined to be 390 W and 852~1,358 mL/min.