• Title/Summary/Keyword: UV/chlorine

Search Result 56, Processing Time 0.027 seconds

Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents (하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동)

  • Han, Jihee;Sohn, Jinsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.

A study on the characteristics of the components of stabilized chlorine dioxide by UV method (UV법에 의한 안정화 이산화염소 원액 성분 특성에 관한 연구)

  • Kim, Ho-Sun;An, Chang-Jin;Yoon, Je-Yong;Lee, Sang-Duk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 1997
  • Chlorine dioxide is being used to control THMs formation or taste & odor in water treatment plant. Recently, some operators or academic circles doubted the effectiveness of stabilized chlorine dioxide which is presumed as a liquid form of chlorine dioxide. In this study, we investigated components which consist of stabilized chlorine dioxide in terms of chlorine dioxide and chlorite. Two analytical methods used in this study are UV method and Iodometric method. Iodometric method is recommended by Korean EPA to check the purity of stabilized chlorine dioxide. The samples of stabilized chlorine dioxide from four water treatments were investigated and compared with that produced from chlorine dioxide generator on-site. This study demonstrated that the component of stabilized chlorine dioxide was overwhelmingly chlorite (${ClO_2}^-$) not chlorine dioxide ($ClO_2$) by UV method. It was also proved that Iodometric method (2nd method) recommended by Korean EPA could not differentiate between $ClO_2$ and ${ClO_2}^-$. Iodometric method (2nd method) recommended by Korean EPA should be revised accordingly to measure chlorine dioxide properly.

  • PDF

Removal of microorganic pollutants based on reaction model of UV/chlorine process (자외선/염소 반응해석 모델에 의한 미량유기물질 제거에 관한 연구)

  • Hwang, Tae-Mun;Nam, Sookhyun;Kwon, Minhwan;Kang, Joon-Wun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.73-81
    • /
    • 2017
  • The UV/chlorine process is a UV-based advanced oxidation process for removing various organic pollutants in water. The process is becoming increasingly popular because of its effectiveness in practice. It is important to the safe and efficient operation of a UV/chlorine process that the optimal operating conditions for both target removal objective and saving energy are determined. Treatment efficiency of target compounds in UV/chlorine process was mainly affected by pH and scavenging factor. In this study, kinetic based mathematical model considering water characteristics and electrical energy dose calculations model was developed to predict of treatment efficiency and optimal operating conditions. The model equation was validated for the UV/chlorine process at the laboratory scale and in pilot tests at water treatment plants.

HAAs Formation by Chlorine Dose and Reaction Time and The Removal Effect of Precursors by The Advanced Oxidation Processes (염소주입량과 반응시간에 따른 HAAs 생성과 고도산화처리에 의한 전구물질 제거 영향)

  • Kim, Kyoung-Suk;Oh, Byung-Soo;Ju, Seul;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.145-150
    • /
    • 2004
  • This study investigated the effect of chlorine dose and chlorine reaction time for the formation of haloacetic acids (HAAs). According to the results, HAA formation was highly affected by chlorine dose and chlorine reaction time. HAA formation reached a plateau value at 30 mg/L of chlorine dose and 24 hr of chlorine reaction time. For the speciation of formed HAAs in the test water, the concentration of brominated-HAAs was significantly lower than that of chlorinated-HAAs because of low level of bromide ion concentration in the test water. It also investigated the removal efficiency of HAA precursors by several unit processes, such as ozone alone, UV alone, and combined ozone/UV system. Of them, ozone/UV system was proved as the best process to control the HAAs formation. The increase of the brominated-HAAs was observed during ozonation with and without UV irradiation showing the slight increase of total HAA concentrations.

Deconvolution of UV Spectrum for Selective Measurement of $ClO_2$ Concentration Quantitatively in Solution Containing Various Chlorine Species (다양한 염소 종이 함유된 수용액에서 자외선 흡수 파장 분해법을 이용한 이산화염소 선별 정량 분석)

  • Byun, Youngchul;Kim, Jaehoon;Jang, Yumi;Lee, Kiman;Lee, Jae Myeong;Shin, Dong Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.743-750
    • /
    • 2012
  • An ultraviolet (UV) absorption method has a difficulty to analyze $ClO_{2(aq)}$ in solutions containing various chlorine species because UV spectrum of $ClO_{2(aq)}$ overlaps with other chlorine-containing species. This study has proposed the deconvolution method of UV spectrum to analyze $ClO_{2(aq)}$ concentration quantitatively in solution containing various chlorine species. We compared results obtained from UV deconvolution method with titration method. Good agreement of $ClO_{2(aq)}$ concentration between them has been shown in about 10%. This result informs us that the deconvolution method of UV spectrum could be a feasible for the analysis of $ClO_{2(aq)}$ in solution containing various chlorine species.

Behavior of Natural Organic Matter(NOM), Chlorine Residual, and Disinfection By-Products(DBPs) Formation in Pulsed UV Treated Water (Pulsed UV 처리수에서의 자연유기물질, 잔류염소 및 소독부산물 생성 거동)

  • Sohn, Jinsik;Han, Jihee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.685-692
    • /
    • 2012
  • UV technology is widely used in water and wastewater treatment. Many researches have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on NOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics such as NOM. Pulsed UV treatment using UV flash lamp can be operated in the pulsed mode with much greater peak intensity. The pulse duration is typically in microseconds, whereas the interval between pulses is in the order of milliseconds. The high intensity of pulsed UV would mineralize NOM itself as well as change the characteristics of NOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of NOM. The objective of this study is to investigate the effect on NOM, chlorine residual, and chlorinated DBPs formation with pulsed UV treatment.

Reduced Post-Chlorine Dosage Required for Disinfection: Improvement with Ozonation and GAC Process (오존 및 입상활성탄 도입시 후염소 주입량 저감효과 분석)

  • Baek, Young-Ae;Joe, Woo-Hyeun;Kim, Jong-Moon;Choi, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.445-452
    • /
    • 2007
  • This study was carried out to examine effect of post-chlorine dosage reduction by ozonation and GAC process in the field plant for 3years in the "G" water purification plant in Seoul. And it is to compare GAC with BAC process in removal effects of TOC, THMs, THMFP, $UV_{254}$. As a result, chlorine dosage of ozonation and GAC(=BAC) is less demand than GAC. Seasonal reduction of chlorine demand is from about 37% to 59% with BAC, and from 24 to 46% with GAC. Higher reduction in BAC could be achieved. The efficiency of chlorine demand reduction with ozonation was depending on the organic carbon removal. $UV_{254}$ concentration is less about 0.13~0.74L/mg.m in BAC than GAC. Therefore, the combination of ozonation and GAC was more effective in reducing post-chlorine than the single GAC. TOC was also monitored, and results show that a linear relationship between TOC and chlorine demand is appropriate under each treatment process. It means that removal of organic matter(TOC) from finished water is necessary to reduce post-chlorine dosage in clear well and to minimize order of chlorine in distribution systems.

Analysis of Chlorine Species in Chlorine Dioxide Bleaching Liquor and Generation Process by UV-VIS Spectroscopy

  • Wang, Li-Jun;Lee, Seon-Ho;Yoon, Byung-Ho
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04a
    • /
    • pp.78-83
    • /
    • 1999
  • In this paper the extinction coefficients of molecule chlorine ($Cl_2$), chlorine dioxide (ClO$_2$), hypochlorous acid (HClO), chlorous acid ($HClO_2$$_2$) were determined using a PDA UV-VIS spectrophotometer. Based on these, the concentrations of $Cl_2$, $ClO_2$, and HClO in general chlorine dioxide bleaching liquor can be measured. The concentrations of $Cl_2$, $ClO_2$ and $HClO_2$ produced during the generation of methanol based chlorine dioxide generator can also be determined use the same method. The method was thought to be able to give more information in chlorine dioxide bleaching chemistry if combine its use with titration and ion chromatography.

  • PDF

Evaluation of inactivation kinetics on pathogenic microorganisms by free chlorine/UV hybrid disinfection system (전해 염소수/자외선 결합 시스템을 이용한 병원성 미생물의 불활성화 키네틱스 평가)

  • Seo, Young-Seok;Kim, Aerin;Cho, Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.379-388
    • /
    • 2019
  • Chlorination and UV illumination are being widely applied to inactivate a number of pathogenic microbials in the environment. Here, we evaluated the inactivation efficiency of individual and combined treatments of chlorination and UV under various aqueous conditions. UV dosage was required higher in waste water than in phosphate buffer to achieve the similar disinfecting efficiency. Free chlorine generated by electrolysis of waste water was abundant enough to inactivate microbials. Based on these, hybrid system composed of sequential treatment of electrolysis-mediated chlorination and UV treatment was developed under waste water conditions. Compared to individual treatments, hybrid system inactivated bacteria (i.e., E. coli and S. typhimurium) and viruses (i.e., MS-2 bacteriophage, rotavirus, and norovirus) more efficiently. The hybrid system also mitigated the photo re-pair of UV-driven DNA damages of target bacteria. The combined results suggested the hybrid system would achieve high inactivation efficiency and safety on various pathogenic microbials in wastewater.