• Title/Summary/Keyword: UT measurement

Search Result 39, Processing Time 0.023 seconds

Effects of Changes in Exercise Intensity on Resting Metabolic Rate (RMR) and Energy Expenditure in Young Men (운동강도의 차이가 안정시대사량 및 에너지 소비량에 미치는 영향)

  • Kawk Yi-Sub;Jin Young-Wan;Park Chan-Ho
    • Journal of Life Science
    • /
    • v.15 no.3 s.70
    • /
    • pp.352-358
    • /
    • 2005
  • The purpose of this study was to examine the effect of various exercise intensity on Resting Metabolic Rate (RMR), excess post exercise energy expenditure (EPEE), and thyroid hormonal changes in trained (TR) and untrained (UT) people. The subject of the present study were divided into two groups and four periods: trained (TR; n=6) and untrained (UT; n=6) group. And the periods were divided as follows; Resting (R), Maximal (M), High intensity (H), and Low intensity (L). The percent body fat and RMR of all subjects were measured at every periods. The RMR was measured early in the morning following a 12-hour fast using MMX3B gas analyzer and blood sample were collected from the anticubital vein to investigate thyroid hormonal (T3, T4, Free T3, Free T4, & TSH) changes. All the RMR values were expressed as absolute value/BSA $(kcal/d/m^2)$. And We also analyzed mean energy expenditure for 30 minutes during and after different intensity exercise. There was significant difference in RMR among different intensity of exercise. in TR (p < .05) not in the UT group. however, there was no significant different percent body fat in TR and in UT group. In the energy expenditure, there was significant different between TR and UT in HEE (high intensity exercise energy expenditure), LEE (low intensity exercise energy expenditure), HEEPE (high intensity exercise energy expenditure post exercise) & LEEPE (low intensity exercise expenditure post exercise). In the hormonal level, there was significant different in T4 level in the TR group at H period and in T4, Free T3, & Free T4 levels in TR group at L period, however there was no significant different in the UT group. The present cross-sectional study was design to investigate the relationship between exercise intensity and RMR. The focus of this investigation was to compare RMR in aerobically trained (TR) and untrained (VI). The relationship among RMR, exercise intensity and percent body fat would best be investigated using MMX3B and body composition analyzer. Each subject completed measurement of percent body fat, RMR, hormone in the period of maximal oxygen uptake exercise (M), high intensity exercise (H), and low intensity exercise (L). From the results, Low intensity of exercise (L), there was a trend for an increased RMR (kcal/day) in the TR not for the UT. This is best explained not by the reduced percent body fat but by the highly induced energy expenditure (during exercise and post exercise energy expenditure) and increased T4, Free T3, and Free T4 hormonal levels in the low intensity exercise for the TR group.

Precise Orbit Determination Based on the Unscented Transform for Optical Observations

  • Hwang, Hyewon;Lee, Eunji;Park, Sang-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.249-264
    • /
    • 2019
  • In this study, the precise orbit determination (POD) software is developed for optical observation. To improve the performance of the estimation algorithm, a nonlinear batch filter, based on the unscented transform (UT) that overcomes the disadvantages of the least-squares (LS) batch filter, is utilized. The LS and UT batch filter algorithms are verified through numerical simulation analysis using artificial optical measurements. We use the real optical observation data of a low Earth orbit (LEO) satellite, Cryosat-2, observed from optical wide-field patrol network (OWL-Net), to verify the performance of the POD software developed. The effects of light travel time, annual aberration, and diurnal aberration are considered as error models to correct OWL-Net data. As a result of POD, measurement residual and estimated state vector of the LS batch filter converge to the local minimum when the initial orbit error is large or the initial covariance matrix is smaller than the initial error level. However, UT batch filter converges to the global minimum, irrespective of the initial orbit error and the initial covariance matrix.

Demonstration of EPRI CHECWORKS Code to Predict FAC Wear of Secondary System Pipings of a Nuclear Power Plant

  • Lee, Sung-Ho;Seong Jegarl;Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.375-384
    • /
    • 1999
  • The credibility of CHECWORKS FAC model analysis was evaluated for plant application in a model plant chosen for demonstration. The operation condition at each pipe component was defined before the wear rate analysis by plant data base, water chemistry analysis, and network flow analysis. The predicted wear was compared with the measured wear for 57 sample components selected from 43 susceptible line groups analysed. The inspected 57 locations represent components of highest predicted wear in each line group. Both absolute value and relative ranking comparisons indicated reasonable correlations between the predicted and the measured values. Four components showed much higher measured wear rates than the predicted ones in the feed water train from main feed water pump discharge to steam generator, probably due to high hydrazine concentration operation the effect of which had not been incorporated into the CHECWORKS model. The measured wear was higher than the predicted one consistently for components with least susceptibility to FAC. It is believed that the conservatism maintained during UT data analysis dominated the measurement accuracy. A great deal of enhancement is anticipated over the current plant pipe management program when a comprehensive plant pipe management program is implemented based on the model analysis.

  • PDF

Development of Steam-Generator UT System and Experimental Verification (증기발생기 전열관 확관부의 초음파 검사장치 및 적용기술개발)

  • Park, Jae-Seok;Hong, Soon-Sin;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.442-448
    • /
    • 2007
  • The ultrasonic inspection system for the expansion/transition area of steam generator tube was successfully developed. Variety of artificial flaw and real track specimen was tested using the UT system to verify the performance of the system. All artificial flaws of which through-wall depth larger than 10% was clearly detected by UT system. Measurement results of through-wall depth of flaws larger than 20% had good linearity and reproducibility with 3.27 of standard deviation. Results of real crack specimen test suggested that the detection limit of real crack strongly depends on the track morphology. A potential for measurement of PRL(percentage of remaining ligament) was recognized by the real crack specimen test.

Characteristics of shoulder pain, muscle tone and isokinetic muscle function according to the scapular position of elite boxers

  • Lee, Ju-Hong;Kim, Ho;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.98-104
    • /
    • 2020
  • Objective: The shoulders are a particularly an important body part for elite boxers. The purpose of this study was to investigate the characteristics of the upper trapezius (UT), infraspinatus (IS) muscle tone, pain, and isokinetic muscle function of shoulder movements such as external rotation, internal rotation, protraction, and retraction according to the scapular position of elite boxers of the Korean national team. Design: Cross-sectional study. Methods: Using the double square method, the scapular position was measured and divided into the forward scapular position group (n=8) with a measurement distance of 135 mm or more, and the normal scapular position group (n=10) with a measurement distance of less than 135 mm. Through the numeric rating scale of the subject, the pain value displayed during movement was measured. The muscle tone of the subjects' UT and IS were measured. The isokinetic muscle function of ER, IR, protraction, and retraction were measured using isokinetic exercise equipment. Results: The results of this study showed statistically significant differences when comparing muscle tone of the UT and IS, shoulder pain, isokinetic function of ER and IR, protraction, and retraction according to scapular position (p<0.05). Conclusions: The findings of this study were that shoulder muscle tone, pain, and isokinetic muscle function were affected according to the scapular position of elite boxers. In the future, this information may be a useful indicator when studying the effects of medium and long-term intervention in elite boxers who possess these characteristics.

International Comparison of Absolute Activity Measurement of $^{133}Ba$ Solution ($^{133}Ba$ 용액의 방사능 절대측정의 국제비교)

  • Park, Tae-Soon;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.130-136
    • /
    • 1985
  • The activity measurement of a solution of $^{133}Ba$ which is an electron capture nuclide was carried out by the ${\beta}-{\gamma}$ coincidence method. The counting rates at the ${\beta}-,\;{\gamma}-$, and coincidence-channels were measured using a $4{\pi}$ proportional counter and two NaI(Tl) scintillation detectors. The specific activity of the solution calculated by the efficiency extrapolation was $(1151.01{\pm}2.99)kBqg^{-1}$ at the reference time(00h UT, 03-15-84). According to an international comparison of activity measurements organized by the Bureau International des Poids et Mesures, this result showed the difference of 0.94% to the mean value derived from the comparison.

  • PDF

Measurement of Longitudinal and Transverse Wave Speed in Solid Materials Using Immersion Ultrasonic Testing (수침 초음파 시험법을 이용한 고체의 종파와 횡파 속도의 측정)

  • Shin, Yo-Sub;Yoon, Yeo-Ho;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • Immersion ultrasonic testing (UT) was used to determine elastic moduli of solid materials instead of the widely-used contact UT method. Conventionally, immersion UT is only used for determining the longitudinal wave speed. However, in this research, transverse wave speed was measured through finding transverse wave echoes caused by mode-conversion at material's boundary. Also, even in the cases when wave speeds could not be determined due to unknown thickness, Poisson's ratio was able to be calculated from the ratio of longitudinal and transverse wave speeds. This technique was verified for several materials, and it was found that higher accuracy was obtained by immersion UT method for materials either with relatively high wave speed or with relatively small Poisson's ratio. This technique thus will be suitable fur ceramics or high strength materials.

Economic Analysis of Installing Fixed and Removable Insulation for Pipe Wall Thinning Management (배관감육 관리를 위한 고정식 및 탈착식 보온재 설치 경제성 분석)

  • Hwang, Kyeongmo;Yun, Hun
    • Corrosion Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.320-325
    • /
    • 2016
  • To perform ultrasonic testing (UT) thickness measurement of the secondary side piping installed in nuclear power plants, the insulation for preventing heat loss should be removed. The type of insulation can be divided into fixed and removable insulation. Fixed and removable insulation have their own strengths and weaknesses. Removable insulation has been installed in the components susceptible to wall thinning caused by FAC and erosion from Shin-Kori unit 1, which commenced its commercial operation in 2011. In this paper, the number of repeated inspections of components and the number of replacements of fixed insulation were estimated and a more economical way was identified based on the manufacturing and installation costs for fixed and removable insulation.

Round Robin Test for Reliability Evaluation of Ultrasonic Thickness Measurement Results in Nuclear Power Plant Pipelines (원전감육배관 UT 두께측정 결과의 신뢰도 평가를 위한 다자비교시험)

  • Lee, Seung-Joon;Yi, Won-Geun;Lee, Joon-Hyun;Lee, Sung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1702-1707
    • /
    • 2007
  • The reduction of pipe-thickness induced by flow accelerated corrosion (FAC) is one of the most serious problems on the maintenance of piping system in nuclear power plants (NNP). If the thickness of a pipe component is reduced below the critical level, it cannot sustain pressure and consequently results in leakage or rupture. For this reason, wall thinning by FAC has been inspected in secondary side piping systems in NPPs. In this research Round Robin Test (RRT) was conducted to verify confidence of wall thinning measurement system in NPP. 12 inspectors from 3 companies participated and 23 specimens were used according to standard practice in RRT. The gage R&R analysis was introduced in regard to repeatability and reproducibility that are affected to measurement system errors. Confidence intervals of thickness measurement system were obtained.

  • PDF

Isolated Activation of the Upper Trapezius in Three Manual Muscle Testing Position : Convergence Study (세 가지 도수근력 검사 자세에서 상부 승모근의 독립적 수축 : 융합적 연구)

  • Ha, Sungmin
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.83-88
    • /
    • 2020
  • The purpose of this study was to investigate the optimal position among three manual muscle tested positions for upper trapezius in which to obtain an isolated upper trapezius EMG signal for the normalization of upper trapezius muscle EMG activity. A total of 28 healthy adult men participated in the experiment. The UT (upper trapezius) and LS (levator scapulae) muscle activities were measured using the TeleMyo 2400T and analyzed using MyoResearch software. The muscle activity of the US and LS was measured by performing three manual muscle test positions for the upper trapezius. The UT/LS ratio during the S-MVIC was 80.25 and was significantly higher than that during the T-MVIC (76.50; p = 0.011) and the C-MVIC (60.95; p < 0.001). And, the UT/LS ratio during the T-MVIC and was significantly higher than that during the C-MVIC (p < 0.001). Based on the results of present study, we suggest a switch from T-MVIC to S-MVIC for the independent normalization reliability of upper trapezius EMG activity. The UT muscle strength or normalization test using S-MVIC will be able to measure muscle strength or activity of UT compared to previous measurement methods.