• Title/Summary/Keyword: UT

Search Result 479, Processing Time 0.031 seconds

Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

  • Jang, Ju-Kyong;Kwak, Sangwon;Choi, Ga Young;Ha, Jung-Hong;Choi, Sung-Baik;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.53 no.10
    • /
    • pp.743-750
    • /
    • 2015
  • Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity $37^{\circ}C$ temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan's post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were $3.62{\pm}0.81mg$, $2.84{\pm}0.28mg$, and $2.73{\pm}0.90mg$ for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.

Development of Intelligent Database Program for PSI/ISI Data Management of Nuclear Power Plant (Part II) (원자력발전소 PSI/ISI 데이더 관리를 위한 지능형 데이더베이스 프로그램 개발 (제 2보))

  • Park, Un-Su;Park, Ik-Keun;Um, Byong-Guk;Lee, Jong-Po;Han, Chi-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.200-205
    • /
    • 2000
  • In a previous paper, we have discussed the intelligent Windows 95-based data management program(IDPIN) which was developed for effective and efficient management of large amounts of pre-/in-service inspection(PSI/ISI) data of Kori nuclear power plants. The IDPIN program enables the prompt extraction of previously conducted PSI/ISI conditions and results so that the time-consuming data management, painstaking data processing and analysis of the past are avoided. In this study, the intelligent Windows based data management program(WS-IDPIN) has been developed as an effective data management of PSI/ISI data for the Wolsong nuclear power plants. The WS-IDPIN program includes the modules of comprehensive management and analysis of PSI/ISI results, statistical reliability assessment program of PSI/ISI results(depth and length sizing performance etc), standardization of UT report form and computerization of UT results. In addition, the program can be further developed as a unique PSI/ISI data management expert system which can be part of the PSI/ISI total support system for Korean nuclear power plants.

  • PDF

Effect of Shoulder Position on Scapular Muscle Activity during Scapular Protraction

  • Yun, Sung Joon;Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.3
    • /
    • pp.157-162
    • /
    • 2020
  • Purpose: This study was to evaluate several tasks performed at a high intensity in terms of their ability to elicit EMG activity in the serratus anterior by comparing the EMG activities of the serratus anterior, upper trapezius, and lower trapezius muscles during six tasks combined shoulder flexion with rotation. Methods: Fifteen healthy males were recruited to this study. Each subject was instructed to assume a sitting position without back support and asked to flex (90° or 120°) the right shoulder and protract the scapula in the sagittal plane with maximal external rotation; to assume a neutral position; or to internally rotate the glenohumeral joint. The EMG data were collected from the serratus anterior (SA), upper trapezius (UT), and lower trapezius (LT) muscles were normalized to maximum voluntary isometric contraction. The UT/LT and UT/SA muscle activity ratios in each task were assessed by calculating the surface EMG. Data were analyzed by two-way repeated-measures analysis of variance, with the level of significance set at p<0.05. Results: The results of this study, shoulder flexion with external rotation resulted in low upper trapezius/serratus anterior and upper trapezius/lower trapezius ratios and a relatively high level of serratus anterior activation. Conclusion: Shoulder flexion with external rotation used herein may be considered as important for clinical interventions aimed at selectively increasing SA strengthen and clinical selection of exercises for improving glenohumeral joint and scapulothoracic control.

Development of Steam-Generator UT System and Experimental Verification (증기발생기 전열관 확관부의 초음파 검사장치 및 적용기술개발)

  • Park, Jae-Seok;Hong, Soon-Sin;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.442-448
    • /
    • 2007
  • The ultrasonic inspection system for the expansion/transition area of steam generator tube was successfully developed. Variety of artificial flaw and real track specimen was tested using the UT system to verify the performance of the system. All artificial flaws of which through-wall depth larger than 10% was clearly detected by UT system. Measurement results of through-wall depth of flaws larger than 20% had good linearity and reproducibility with 3.27 of standard deviation. Results of real crack specimen test suggested that the detection limit of real crack strongly depends on the track morphology. A potential for measurement of PRL(percentage of remaining ligament) was recognized by the real crack specimen test.

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

Effect of Movement Plane and Shoulder Flexion Angle on Scapular Upward Rotator During Scapular Protraction Exercise (운동면과 어깨 관절 굽힘 각도가 어깨뼈 내밈 운동 시 어깨뼈 위쪽 돌림근에 미치는 영향)

  • Choung, Sung-Dae;Weon, Jong-Hyuck;Jung, Do-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • PURPOSE: This study was to determine the effect of the plane of movement (sagittal plane vs. scapular plane) and shoulder flexion angle ($90^{\circ}$ vs. $130^{circ}$) during scapular protraction exercises in healthy subjects by investigating the elecromyographic (EMG) activities of the serratus anterior (SA), upper trapezius (UT), and pectoralis major (PM). METHODS: Twenty-one healthy subjects participated in this study. Subjects performed maximal scapular protraction at the $90^{\circ}$ or $130^{\circ}$ shoulder flexion angles in the sagittal or scapular planes. Surface EMG was recorded from the SA and UT, and PM muscles. Dependent variables were examined by 2 (plane) ${\times}$ 2 (angle) repeated measures of analysis of variance (ANOVA). RESULTS: Significantly increased EMG activities in the SA and UT were found during scapular protraction exercise at the $130^{\circ}$ shoulder flexion angle in the sagittal and scapular plane. Also, EMG activity of the PM significantly decreased at the $130^{\circ}$ shoulder flexion angle in the sagittal plane and the $90^{\circ}$ and $130^{\circ}$ shoulder flexion in the scapular plane. CONCLUSION: we recommend scapular protraction exercise at the $90^{\circ}$ shoulder flexion in the sagittal plane to selectively strengthen the SA muscle with limitation of upper trapezius activity and at the $130^{\circ}$ shoulder flexion in the scapular plane to selectively strengthen the SA muscle with limitation of pectoralis major activity.

Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing (비규격 초음파 탐상용 표준시험편의 사용안전성 평가)

  • Kwon, Ho-Young;Lim, Jong-Ho;Kang, Sei-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.431-437
    • /
    • 2000
  • Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects.

  • PDF

The Effect of Visual Feedback of Head Angles With Using a Mobile Posture-Aware System on Craniocervical Angle and Neck and Shoulder Muscles Fatigue During Watching the Smartphone

  • Kim, Su Jeong;Jeong, So Yeon;Yoon, Tae Lim
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.2
    • /
    • pp.47-53
    • /
    • 2018
  • Purpose: To find the effect of visual feedback of head angle with using a mobile posture-aware system on craniocervical angle and neck and shoulder muscles fatigue for preventing or decreasing the forward head posture. Methods: Twenty-four healthy young adults in Chungbuk to participate in this study. The subjects started to watch a movie clip for 10 minutes with visual feedback in $0^{\circ}$, $30^{\circ}$, and $60^{\circ}$ of head angles. During the task, surface electromyography (EMG) was used to collect data from the upper trapezius (UT), sternocleidomasetoid muscle (SCM), cervical erecter spinae (CES) during watching the smartphone. Craniocervical angles were measured using a sagittal-view photograph of the subject in a sitting posture. A one-way repeated analysis of variance with a significant level of 0.05 used for statistical analysis. Results: Craniocervical angle with $0^{\circ}$ visual feedback was significantly greater than $30^{\circ}$ and $60^{\circ}$. Craniocervical angle with $30^{\circ}$ visual feedback was significantly greater than $60^{\circ}$. In addition, MDF of UT muscles in $0^{\circ}$ and $30^{\circ}$ of visual feedback was significantly greater than $60^{\circ}$. Conclusion: We concluded that $0^{\circ}$ visual feedback of head angle with using a mobile posture-aware system would be beneficial to prevent or decrease forward head posture during watching a smartphone. We also could recommend using of $30^{\circ}$ visual feedback in case of caring UT muscle fatigue primarily.

Automatic Ultrasonic Inspection on Heater Sleeves and J-Groove Welds of Pressurizer (가압기 전열기 슬리브 및 J-Groove 용접부의 자동 초음파검사)

  • Ryu, Sung Woo;Chang, Hee Jun;Kim, Sun Je;Lee, Sang Duck;Sung, Jong Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.20-27
    • /
    • 2010
  • In order to prevent the corrosion of component contacted primary water designed alloy 600 material in the nuclear power plant. But the primary water stress corrosion cracking(PWSCC) of alloy 600 and weld area occurs continuously due to the residual stress. The leakage accident resulted from PWSCC in the drain nozzle of the steam generator of domestic power plants. Heater sleeves of the pressurizer are welded with alloy 600 weld material and therefore exposed to the primary water environment. PWSCC occurred in heater sleeve material and weld area of many foreign power plants. The current issue of domestic nuclear power plants are consequently concentrated to PWSCC of similar material. In order to improve the detection and the sizing of the PWSCC in the welding sleeve of the pressurizer, the automatic UT system and multi-directions probe sets have been developed. The experimental studies have been performed using the mock-up block containing artificial reflectors(ID connected EDM notch) and semi-artificial cracks made from thermal fatigue. The automatic UT System is applied in the detection and the length sizing of the ID/OD on the tube and the J-groove weld area of the artificial reflectors and results of the detection and the sizing are compared respectively. Also, the developed automatic UT system is successfully accomplished to inspect the heater sleeve and the J-groove weld area on the pressurizer for the detection of PWSCC.

  • PDF

Relation between Earthward magnetotail flow and low-latitude Pi2 pulsations

  • Kwon, Hyuck-Jin;Kim, Khan-Hyuk;Lee, Dong-Hun;Takahashi, Kazue;Lee, Ensang;Angelopoulos, Vassilis;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.121.1-121.1
    • /
    • 2012
  • It has been suggested that oscillatory earthward bursty bulk flows (BBFs) in the magnetotail are driving Pi2 oscillations on the ground. However, only a few studies examined the BBF-driven Pi2 model. The goal of this study is to establish the relation between BBFs and Pi2s. In order to examine BBF-drive model, we will conduct the timing analysis between BBFs and Pi2s for the intervals during which both Pi2 and BBF are present. In our study BBFs are identified with earthward flow speeds up to 200 km/s from THEMIS probes with a geocentric distance between 7 and 12 RE in the nightside magnetosphere for the interval from January 2008 to March 2008. Pi2 pulsations are identified at three low/mid-latitude ground stations having different local times; Bohyun (L = 1.35, LT ~ UT +9 hr), Hermanus (L = 1.83, LT ~ UT +2 hr) and Carson city (L = 2.00, LT ~ UT -2 hr). It is found that ~28% of BBFs have onset timing nearly identical to Pi2 onset. To investigate whether there is high similarity in the waveform between BBF and Pi2 oscillations, the coherence analysis is applied to the time series of BBF and Pi2 events. We found that there is no high coherence between BBF and Pi2 oscillations. Thus our observations suggest that low-latitude Pi2 oscillations are not directly driven by earthward flow bursts.

  • PDF