• 제목/요약/키워드: UPS systems

검색결과 162건 처리시간 0.027초

병렬운전 UPS 시스템의 독립 부하 분담 특성 (Independent Load Sharing of UPS systems connected in Parallel)

  • 변영복;구태근;조기연;김동희;김철우;아나니에프
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2546-2548
    • /
    • 1999
  • This paper describes characteristics of independent load sharing of parallel UPS systems and proposes a method of control which does not require control interconnections at each UPS system and compensates for line impedance. Simulation results of a two-module UPS system with different power latins and line impedance have demonstrated the feasibility of the proposed control scheme in load sharing.

  • PDF

Digital Control of a Single-Phase UPS Inverter for Robust AC-Voltage Tracking

  • Woo Young-Tae;Kim Young-Chol
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권4호
    • /
    • pp.620-630
    • /
    • 2005
  • This paper presents a digital controller for a single phase UPS inverter under two main considerations: (i) the overall system shall keep very low AC-voltage tracking error as well as no phase delay over different load conditions, and (ii) the digital controller shall be employed at a fixed sampling time. We propose that the former can be achieved by the proposed controller using the error-state approach and the latter can be dealt with by the socalled characteristics ration assignment.

Verification of an Autonomous Decentralized UPS System with Fast Transient Response Using a FPGA-Based Hardware Controller

  • Yokoyama, Tomoki;Doi, Nobuaki;Ishioka, Toshiya
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.507-515
    • /
    • 2009
  • This paper proposes an autonomous decentralized control for a parallel connected uninterruptible power supply (UPS) system based on a fast power detection method using a FPGA based hardware controller for a single phase system. Each UPS unit detects only its output voltage and current without communications signal exchange and a quasi dq transformation method is applied to detect the phase and amplitude of the output voltage and the output current for the single phase system. Fast power detection can be achieved based on a quasi dq transformation, which results in a realization of very fast transient response under rapid load change. In the proposed method, the entire control system is implemented in one FPGA chip. Complicated calculations are assigned to hardware calculation logic, and the parallel processing circuit makes it possible to realize minimized calculation time. Also, an Nios II CPU core is implemented in the same FPGA chip, and the software can be applied for non-time critical calculations. Applying this control system, an autonomous decentralized UPS system with very fast transient response is realized. Feasibility and stable operation are confirmed by means of an experimental setup with three UPSs connected in parallel. Also, rapid load change is applied and excellent performance of the system is confirmed in terms of transient response and stability.

An Equivalent Load Sharing by Wireless Parallel Operation Control in UPS

  • Byun, Young-Bok;Koo, Tae-Geun;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • Journal of KIEE
    • /
    • 제10권1호
    • /
    • pp.35-42
    • /
    • 2000
  • An equivalent load sharing control based on the frequency and voltage droop concept for parallel operation of two three-phase Uninterruptible Power Supply (UPS) systems with no control interconnection lines is presented in this paper. First of all, due to the use of active power and reactive power as control variables, the characteristics of output powers according to amplitude and phase differences between output voltages of two UPS systems are analyzed. Secondly, simulation results under different line impedance demonstrate the feasibility of the wireless parallel operation control. Finally, experiments are presented to verify the theoretical discussion with two three-phase 20kVA UPS systems employed TMS320C32, a kind of real time digital signal processor (DSP).

  • PDF

지휘무장통제체계용 UPS 배터리의 안전성 확보방안 연구 (A Study on the application method of UPS's Battery Safety for battleship Command and Fire Control System)

  • 박건상;김재윤;김동규
    • 한국산학기술학회논문지
    • /
    • 제22권3호
    • /
    • pp.587-596
    • /
    • 2021
  • 해군 함정에는 특수목적을 수행하기 위해 구성되어있는 시스템이 있다. 그 중에는 지휘무장통제체계(CFCS : Command and Fire Control System, 이하 CFCS)가 존재하며 이를 운용하기 위해 요구사항에 맞는 장비가 개발된다. 특히 이러한 장비들 중 일부는 함정의 발전기 문제나 기타 예기치 못한 상황에서 정전이 발생하더라도, 운용 지속성 및 중요한 자료를 백업할 수 있도록 무정전전원공급장치 (UPS : Uninterruptible Power System, 이하 UPS)를 적용해야한다. 만약 이를 충족하지 못할 경우 전력손실로 이어진다. 그러므로, 우리는 안정적인 UPS가 적용될 수 있도록 방안을 강구해야한다. 안정적인 UPS를 설계하기 위해 배터리와 배터리관리시스템 (BMS : Battery Management System, 이하 BMS)은 중요한 요소가 된다. 만약 이러한 배터리와 BMS가 불안정하게 되면 전원문제가 발생할 경우 중요한 전술 정보가 손실되거나 전투체계 수행업무를 정상적으로 할 수 없게 되므로 큰 전력 공백이 발생한다. 즉, 본 시스템의 안전성 확보가 필수적이다. 따라서, 본 논문에서는 CFCS에 적합한 UPS 개선을 위해 배터리 비교분석, 주요회로 누설전류 분석, 내환경성 시험을 토대로 개선된 시스템을 구현 및 검증하였다.

Line-Interactive UPS for Low-Voltage Microgrids

  • Zhang, Ping;Cai, Huanyu;Zhao, Hengyang;Shi, Jianjiang;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1628-1639
    • /
    • 2015
  • Line-interactive uninterruptible power supply (UPS) systems are good candidates for providing energy storage within a microgrid. In this paper, a control scheme for a line-interactive UPS system applied in a low-voltage microgrid is presented. It is based on the Q-w and P-E droop control to achieve a seamless transition between grid-connected and stand-alone operation modes. Moreover, a new model for designing the controllers is built in the dq-frame based on the instantaneous power definition. The new-built model takes into account the dynamic performance of the output impedance of the inverter in the dq-frame and can be evaluated in the time domain. Compared to the traditional model based on the instantaneous power definition, the new-built model is more accurate to describe the dynamic performance of the system. Simulation and experimental results obtained with a microgrid consisting of two 40-kW line-interactive UPS systems are given to validate the control strategy of the line-active UPS system and the accuracy of the new-built model.

정보통신용 다병렬 운전의 모듈식 무정전전원장치 (Module UPS of multi-parallel operation for use in information & telecommunication systems)

  • 구태근;류지수;배상규;박근갑
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

3상 오프라인 무정전 전원 시스템의 돌입전류 제거 (Inrush Current Elimination for a Three-Phase Off-Line UPS System)

  • ;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.944-945
    • /
    • 2015
  • Many sensitive loads always rely on UPS systems to maintain continuous power during abnormal utility power conditions. As any disturbance occurs at the utility side, an off-line UPS system takes over the load within a quarter cycle to avoid a blackout. However, the starting of the inverter can root the momentous inrush current for the transformer installed before the load, due to its magnetic saturation. The consequences of this current can be a reduction of line voltage and tripping of protective devices of the UPS system. Furthermore, it can also damage the transformer and decrease its lifetime by increasing the mechanical stresses on its windings. To prevent the inrush current, and to avoid its disruptive effects, this paper proposes an off-line UPS system that eliminates the inrush current phenomenon while powering the transformer coupled loads, using a current regulated voltage source inverter (CRVSI) instead of a typical voltage source inverter (VSI). Simulations have been performed to validate the operation of proposed off-line UPS system.

  • PDF

The study of the restaurant start-up chatbot system using big data

  • Sung-woo Park;Gi-Hwan Ryu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권3호
    • /
    • pp.52-57
    • /
    • 2023
  • In the restaurant industry, along with the fourth industry, there is a food technology craze due to IT development. In addition, many prospective restaurant founders are increasing due to restaurant start-ups with relatively low entry barriers. And ChatGPT is causing a craze for chatbots. Therefore, the purpose of this paper is to analyze factors for restaurant start-ups with big data and implement a system to make it easier for prospective restaurant start-ups to recommend restaurant start-ups that suit them and further increase the success rate for restaurant start-ups. Therefore, this paper is meaningful in analyzing the start-up factors desired by prospective restaurant founders with big data, turning them into text, and furthermore, designing and studying the start-up factors shown as big data into a restaurant start-up chatbot system.

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.