• Title/Summary/Keyword: UPS design

Search Result 211, Processing Time 0.031 seconds

Design of Deadbeat DSP Controlled PWM Inverter With Two-Level Switching Pattern

  • Choi Seong-Kwan;Park Hae-Won;Kim Soon-Young;Seok Won-Yeob;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.151-154
    • /
    • 2001
  • In this paper, a two-level switching algorithm of the deadbeat to control PWM inverter is proposed. A modified algorithm of the deadbeat is suitable for the UPS system. Two levels in the pulse pattern are used. This scheme allows the use of higher switching frequency for a given computation time delay, which results in lower total harmonic distortion at the output. The proposed control scheme is implemented using TMS320F240 DSP chip for controlling on inverter.

  • PDF

ON THE DEVELOPMENT OF STUD AND ARC WELDING DUAL-PURPOSE ROBOT SYSTEM (스터트 및 아크 용접 겸용 로보트 시스템의 개발)

  • 이용중;유범상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.582-587
    • /
    • 1993
  • A robot application system is developed for dual purpose of stud welding and are welding to weld plates in the manufacturing of elevator cabin. The production quantity is not so big to accommodate separate stations for stud welding and are welding respectively while the need for randomization of the processes is urgent. A robot with specification for spot welding is chosen, which is appropriate for stud welding. Some implementations are made so that the robot may also be shared for are welding process. Common jig and fixture is designed for the dual purpose. Important aspects in the procedure of system design, installation, and commissioning are stated, and signal set-ups and logic diagrams are illustrated.

  • PDF

Design and Analysis of Instantaneous Voltage Drop Compensator (순간전압강하 보상기의 설계와 해석)

  • Lee, Taeck-Kie;Hyun, Dong-Seok;Hwang, Yong-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.478-481
    • /
    • 1991
  • This paper discusses the principle and structure of instantaneous voltage drop compensator, which protects damage from instantaneous voltage drop in systems such as computer, variable speed drive, high voltage discharge-lamp, magnet switch. When instantaneous voltage drop occurs, control circuits detect it, then produce output voltage the same as normal condition voltage. Instantaneous voltage drop compensator has condenser bank as energy storage component, so system can be made small, light weight compared with UPS. In normal state, utility source transfers power, and in instantaneous voltage drop state, the energy of condenser bank transfers power through inverter, so high efficiency, compact, and especially low cost system can be manufactured.

  • PDF

Operational Characteristics of DC Reactor Type SFCL for Accident of Both Power Source Side and Load Side (전원단 및 부하단 사고에 따른 DC 리액터형 고온초전도 전류제한기 동작특성)

  • Lee, Su-Won;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.140-145
    • /
    • 2004
  • In this paper, we analyzed the operational characteristics of the modified DC reactor type SFCL and derived the design condition of superconducting coil to be operated properly as power source as well as fault current limiter. It was confirmed through the simulation for the operation of this SFCL that the modified DC reactor type SFCL could be operated as both the uninterruptible power supply and the fault current limiter by controlling the duty ratio of GTO thyristor bridge.

SRF-PLL system controller design for 3-phase grid connected inverter (3상 계통연계형 인버터를 위한 SRF-PLL 시스템의 제어기 설계)

  • Lim, Deok-Young;Kwon, Kyoung-Min;Choi, Jae-Ho;Chung, Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.302-304
    • /
    • 2009
  • Phase Locked Loop(PLL) 시스템은 UPS, 전력용 능동필터, PWM 정류기 등 여러 전력변환 장비에서 사용되어 왔다. 특히 계통에 연계된 능동 전력변환 시스템은 계통과의 동기화를 위해 위상각의 정확한 정보가 필요하며 PLL 시스템을 사용하여 측정한다. 실제 계통의 위상각과 추출된 위상각 사이의 오차는 기준 전류나 전압에 더 큰 고조파를 야기한다. 본 논문은 계통 고장에 강인한 PLL 시스템의 제어기를 제안한다.

  • PDF

A Study on the Three Phase Multi-PAM Inverter using the one-chip Microcomputer for UPS. (원칩 마이크로 컴퓨터를 이용한 UPS용 3상 다중 PAM 인버터에 관한 연구)

  • 김성백;이종규
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.2
    • /
    • pp.63-68
    • /
    • 1989
  • This paper discussed the Multi-PAM inverter for static power supply design. The controller part composed of one-chip microcomputer obtained control pattern simply. The configuration of termination part was composed of double bridge inverter and three-phase, three-winding transformer. The output waveforms using a controller and transformers synthesized the multi-PAM wave form by a voltage level of 22 steps per one-cycle. The output waveforms using the Low Pass Filter approximated to the sine wave.

  • PDF

Design of Voltage Controller of DVR based on DSP (DSP를 기반으로한 DVR의 전압제어기 구현)

  • Lee won-sun;Kim soo-gon;Lim Byung-Kuk;Jeon hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.566-569
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Recently, in power system, not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer) are being studied more and more. The DVR is a series compensator which can instantaneously compensate a voltage variation in supply side, and is a more effective than a existing UPS(Uninterruptible Power Supply) which can be only used in limited range of loads such as single load. Hence, in this paper, a study of inverter side L-C filter output Voltage for DVR is discussed.

  • PDF

Nonisolated Bidirectional ZVT DC-DC Converter for an Energy Storage System (에너지 저장 시스템을 위한 비절연 양방향 ZVT DC-DC 컨버터)

  • Han, Ji-tai;Lim, Chang-soon;Kim, Rae-young;Hyun, Dong-seok
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.50-51
    • /
    • 2012
  • The paper presents a non-isolated bidirectional DC-DC converter for use in renewable power generation, battery, electric vehicles (EV) and small scale DC-UPS systems. In the propose design, the conventional interleaved operation of two-inductor boost structure is modified to accommodate bidirectional operation, and zero-voltage-transition (ZVT) is applied, where both the switch and the rectifier diode achieve soft condition without increasing their voltage and current stresses. The proposed converter has the merits of simple circuitry, reduced size, low cost and high efficiency. The operation principle of the converter is analyzed and verified. Also, simulation results of the proposed bidirectional dc-dc converter is shown.

  • PDF

A Study of a Conduction Cooling System of a HTS SMES System (고온초전도체 SMES 장치의 전도냉각시스템 연구)

  • Koh, Deuk-Yong;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.328-332
    • /
    • 2007
  • A superconducting magnetic energy storage (SMES) system has shorter response time and longer life time, and is more economical, and environment-friendly than other uninterruptible power supply (UPS). A conduction cooling system is well answer for the high temperature superconductor (HTS) SMES system. Because the conduction cooling system is simple, light and small structure. The purpose of this paper is to design and verify the effective conduction cooling system for the HTS SMES system. The analysis of heat loads in cryostat is performed. Thermal shield heat loads, temperatures of HTS coil surface and conduction Cu plate are estimated and measured.

Design of a single tuned filter for power factor improvement of UPS (무정전 전원장치의 역률개선을 위한 동조필터 설계)

  • 김수열;김장목
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.54-57
    • /
    • 1999
  • 일산복합화력발전소 소내 중요설비에 전력을 공급하는 무정전 전원장치의 출력측 전압파형의 종합 왜율을 IEEE 출력기준인 5%로 억제하여 설비의 안정적 동작을 확보하기 위하여 고조파 분석을 행하였다. 일산복합의 무정전 전원장치는 제어전원공급용으로서 부하가 콘덴서 입력형 정류기의 특성을 갖고 있으므로 3, 5, 7차의 주요 고조파를 포함하고 있다. 따라서 이들 각각에 대하여 부하측에서 본 무정전 전원장치의 임피던스를 작게 하여 전압종합왜율을 5%이하로 낮추어야 한다. 무정전전원장치의 출력전압, 전류 취득 자료를 분석하여 해당 차수의 고조파 제거와 역류개선을 위한 동조필터의 커패시터와 리액터의 용량을 결정하는 방법을 정리하였다.

  • PDF