• Title/Summary/Keyword: UL94 test

Search Result 43, Processing Time 0.025 seconds

Preparation and Properties of Flame Retardant Epoxy Resins Containing Phosphorous/Silicone Components (인/실리콘 함유 난연성 에폭시 수지의 제조 및 물성)

  • Kim, Chang-Heon;Ha, Do-Young;Lee, Young Hee;Lee, Dong-Jin;Kim, Han-Do
    • Clean Technology
    • /
    • v.23 no.4
    • /
    • pp.378-387
    • /
    • 2017
  • To obtain epoxy resin with permanently attached flame-retardant groups, phosphorus compound containing di-hydroxyl group [10-(2,5-dihydroxyphenyl)-9,10-dihydro-9-oxa-10-phospha phenanthrene-10-oxide, DOPO-HQ] and silicone compound containing di-hydroxyl group (polydimethylsiloxane, hydroxyl terminated, PDMS) were reacted with uncured epoxy prepolymer (diglycidyl ether of bisphenol A, DGEBA) and then cured using 4,4-diaminodiphenylmethane (DDM) as a crosslinking agent. The properties of the resulting epoxy materials were characterized using Fourier transform infrared (FTIR) spectrometer, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), limiting oxygen index (LOI) test/vertical burning test (UL 94-V test), tensile properties test and impact test. This study examined the effect of phosphorus/silicone compound contents on the thermal/mechanical properties and flame retardancy of cured epoxy resins containing phosphorus and silicone compounds. It was found that the thermal/mechanical properties of epoxy resins containing phosphorus and silicone components were higher than those of simple epoxy resin. The flame-retardancy (LOI: 29.9 ~ 31.8% and UL 94-V: V-0) of all samples containing phosphorus compound and phosphrous compound/silicone compound was found to be passed the flame-retardant requirements (LOI: > 30%, UL 94-V: V-0) of LOI and vertical burning tests. However, the flame-retardancy (LOI: 21.4% and UL 94-V: no rating) of simple epoxy resin was found to be failed the flame-retardant requirements.

A study for the test method of fire resistance construction sealant (방화용 실런트 성능 평가 방법 연구)

  • Ahn, Myung-Su;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.179-182
    • /
    • 2013
  • Many kinds of fire-stop sealants have been used for joint sealing, cable penetration part sealing and fireproof structure finishing etc in building sectors which need water-proofing and fire-stop properties. But, fire-stop sealant itself has no specific industry standards in Korea even though there are so many required properties for the application. So, in this study, for the evaluation, we adopted and applied UL standard 94(UL 94) which is commonly used for the fire retardant testing in inflammable materials like plastics and rubbers in electronics industry. In this study, we demonstrated fire resistance properties of each fire-stop sealants which varied with different formulation, thickness and origins available in Korea. Overall, fire stop sealant had better fire resistance performance than normal construction sealant. And the thicker the material, the better the fire resistance performance was. Because there is no national or industry guideline for fire stop sealant itself, each sealant products showed different level of performances under UL94 desigation. Even certain product had very poor fire proof propeties although it claims it can be used for the application.

  • PDF

A Study on Fire Safety of PASCON Cable Trough (PASCON 케이블 트로프의 화재안전성에 관한 연구)

  • 이창우;박재성;최충석;이의평;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.51-59
    • /
    • 2002
  • Manifold physical properties of PASCON cable trough were evaluated, and its suitability of domestic test for flammability of plastic materials was examined. Particularly, suitability of PASCON material was investigated through study on the legal propriety of PASCON cable trough used for highspeed rail line and on a fire safety. As results, domestic test for flammability of PASCON cable trough material(KS M3015) was similar to UL 94 flammability testing and from the test outstanding capability of PASCON cable trough material was proved. Besides, possibility of fire enlargement would be very low in case of fire in PASCON cable trough installed around train express. Also, fire safety of PASCON cable trough was shown to be credible.

Study on Halogen Free Low Smoke Polyolefin (할로겐이 없는 저연성 폴리올레핀에 관한 연구)

  • Kim, Young-Doo;Chung, Kwang-Soo;Kim, Tae-Ho
    • Elastomers and Composites
    • /
    • v.37 no.3
    • /
    • pp.177-182
    • /
    • 2002
  • For low-smoke-type polyolefin compound, LDPE, EVA, and EEA as base resin, magnesium trihydrate, alumina trihydrate, and red phosphorous as flame retardant and MAH type compatibilizer were applied. The amount of each component was changed to find out optimum composition. Mechanical properties were obtained by tensile test and residual stress after aging and flame retardancy was evaluated by smoke density, LOI(Limit Oxygen Index), and UL-94 test. SEM was used for the investigation or morphology and halogen contents were obtained by measuring the amount of HCI. Two kinds of halogen free compositions for flame retardant and low smote resin were found and it is expected to be applied for various purposes.

A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings (건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구)

  • Hong, Sung-Ho;Choi, Moon-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

Flame Retardancy & Mechanical Properties of Mixed Waste $Plastic/Mg(OH)_{2}$ Composites Reinforced with PUB Powder (PUB 분말이 충전된 혼합폐플라스틱/$Mg(OH)_{2}$ 복합소재의 난연성 및 기계적 특성)

  • Jung, Ki-Chang;Song, Jong-Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.65-71
    • /
    • 2006
  • Flame retardancy and mechanical properties of polyolefinic mixed waste plastics/filler composites were investigated by using inorganic flame retardant(magnesium hydroxide) and PUB(polyurethane block) powder generated from cryogenic insulation process. All composites were obtained by extrusion and after compression molding. The effect of PUB powder on the properties of the composites was studied by tensile and izod impact test, morphology studies and flammability as LOI and UL94 vertical burning test and smoke density. The objective of this work is to obtain good mechanical properties from recycled PP composites with $Mg(OH)_{2}/PUB$ powder as fillers and optimum cost-performance balance, in addition to flame retardant characteristics.

A Study on the Preparation and Flame Retardancy of Compatibilized Blend/Layered Silicate Nanocomposites with Inorganic Flame Retardant (무기계난연제 첨가형 상용화블렌드/층상실리케이트 나노복합재료의 제조 및 난연특성에 관한 연구)

  • Kang, Young-Goo;Song, Jong-Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.79-85
    • /
    • 2006
  • Olefinic compatibilized blend(R-PP/R-PE)/layered silicate composites have been prepared by melt intercalation technique directed from $Na^{+}$ montmorillonite(MMT) or organophilic montmorillonites while using magnesium hydroxide as flame retardant. Morphology and flammability properties were characterized by X-ray diffraction(XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM), thermogravimetry analysis(TGA), limiting oxygen index(LOI), UL94 test. It is found that the compatibilized blend/layered silicate(Cloisite 20A) nanocomposites have a mixed immiscible-intercalated structure and there is better intercalation when a compatibilizer is combined with the polymer and layered silicate to be melt blended. A very large increase in the LOI value was observed with hybrid filler addition and further enhancement in thermal stability and compatibility of blend was obtained for the compatibilized blend containing small amount of layered silicate.

Flame Retardancy and Physical Properties of Ethylene Vinyl Acetate/Aluminum Trihydroxide Composites (에틸렌 비닐아세테이트/수산화알루미늄 복합재료의 난연 및 물리적 특성)

  • Lee, Minho;Yu, Dayeong;Kim, Yeongho;Lee, Sunghee;Kim, Jeong Ho;Lee, Young Chul
    • Polymer(Korea)
    • /
    • v.39 no.3
    • /
    • pp.433-440
    • /
    • 2015
  • Aluminum trihydroxide (ATH) has been commonly employed as a flame retardant for ethylene vinyl acetate (EVA) copolymers. In the present work, ATH was obtained from a recycling process of multi-layer packaging film wastes. EVA/ATH composite samples were prepared using a two roll-mill and flame retardancy of EVA/ATH composites were examined using limiting oxygen index (LOI) and flame retardancy test (UL94). We observed excellent flame retardancy in case of adding 150 phr or more of recycled ATH to EVA. Particle size and specific surface area play crucial roles in LOI value and UL-94 classification of the EVA/ATH composites. Smaller particle size and higher specific surface area of ATH was found out to improve the flame retardancy. Regarding tensile properties, crosslinked EVA/ATH compounds which is practically used for electric cables had similar to or even better tensile property values than the ones without ATH.

Thermal and Mechanical Properties of Flame Retardant ABS Nanocomposites Containing Organo-Modified Layered Double Hydoxide (유기변성 LDH를 사용한 난연 ABS 나노복합재료의 열적 및 기계적 물성)

  • Kim, Seog-Jun
    • Elastomers and Composites
    • /
    • v.43 no.4
    • /
    • pp.241-252
    • /
    • 2008
  • ZnAl-LDH(layered double hydroxide) modified with oleic acid(SO-ZnAl LDH) was synthesized and added to the flame retardant ABS compounds containing brominated epoxy resin(BER) and antimony trioxide(${Sb_2}{O_3}$). Flame retardant ABS compounds were manufactured by using a twin-screw co-rotating extruder and subsequently injection molded into several specimen for flame retardancy and mechanical properties. The XRD patterns of ABS nanocomposites showed no peaks. The thermal stability of ABS nanocomposites was enhanced by the addition of SO-ZnAl LDH as shown in TGA results. However, these nanocomposites showed no rating in the UL 94 vertical test at 1.6 mm thickness. Only ABS nanocomposites with additional BER more than 1.5 wt% showed UL 94 V0 rating. Notched Izod impact strength, tensile modulus, and elongation at break of flame retardant ABS nanocomposites increased with the proportion of So-ZnAl LDH whereas their melt index decreased.

A Study on the Characterization of Intrinsic Flame Retardant and Heat Resistant Sulfur-Bridged Heterocyclic Polymers (본질적 난연 및 내열성 헤테로환식 폴리머의 특성에 관한 연구)

  • Young-Goo Kang;Hong Kim;Ho-Suk Ryu
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.173-178
    • /
    • 1997
  • The intrinsic flame retardant and heat resistant polymers such as PQXS [poly( quinoxaline )sulfide], PIQS [poly(isoquinoline)sulfide] and PQS [poly(quinoline)sulfide] were synthesized from 2, 3-dichloroquinoxaline, 1, 3-dichloroisoquinoline and 4, 7-dichloroquinoline. They were characterized by FT-IR, UV/Vis spectroscopy, DTA and elemental analysis. The melting point above $350^{\circ}C$ of the polymers show higher than that of the heat resistant PPS polymer(mp. $295^{\circ}C$), In the LOI test, the polymers exhibit an intrinsically high flame retardant property having the LOI values in the range of 41~42. The vertical burning test for the polymers also show an UL 94 V-0 performance.

  • PDF