• 제목/요약/키워드: UHV

검색결과 208건 처리시간 0.032초

분자선 에피성장법으로 성장된 ZnSe/GaAs의 특성 (Property of molecular beam epitaxy-grown ZnSe/GaAs)

  • 김은도;손영호;조성진;황도원
    • 한국결정성장학회지
    • /
    • 제17권2호
    • /
    • pp.52-56
    • /
    • 2007
  • 본 연구에서는 초고진공(UHV, ultra high vacuum) 분자선 에피성장(MBE, molecular beam epitaxy) 시스템을 제작하여, ZnSe/GaAs[001]을 증착하였고, 증착된 박막의 특성을 SEM(scanning electron microscopy), AFM(atomic force microscopy)으로 조사하여, 분자층 단위의 조밀하고 균일한 표면특성을 보이고 있음을 확인할 수 있었다 XRD(x-ray diffractometer)를 이용하여, GaAs[001]기판의 XRD peak 위치와 ZnSe 박막의 XRD peak 위치가 각자 일치함을 확인할 수 있었다. PL(photoluminescence)로는 대략 437nm에서 발광하는 것이 관측되었으며, 2인치 ZnSe 박막의 PL mapping을 측정하였다.

345/154kV 초고압 송변전설비 주변에서의 자장의 측정과 분석 (Measurement and Analysis of Magnetic Field near 345/154kV UHV Overhead Transmission Lines and Substations)

  • 이정기;안창환;이복희;길경석;박동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1813-1815
    • /
    • 1996
  • With the three dimensional magnetic field measuring system dealt with in this paper, accurate measurements and analyses of ELF magnetic fields in the vicinity of UHV overhead transmission lines and substations have been conducted. For the field measurements multiturn loop-type sensors have been developed with special consideration of taking lower frequency and spatial components without any distortion. So the measuring system has the frequency bandwidth of 8[Hz] to about 53[kHz] and the response sensitivity of $9.88[mV/{\mu}T]$ in average. A brief description of design rules of the measuring system and measurement procedures is given. The actual surrey near 154 and 345[kV] overhead transmission lines and power subststions was carried out and analyzed. It may be inferred from these results that the maximum magnetic field intensities under typical UHV overhead transmission lines do not exceed $20[{\mu}T]$ so that the field measurements satisfy sufficiently all limits or guidelines that various authorized international institutes recommend.

  • PDF

한전 765 kV 송전선로 건설을 위한 강원도 태백.사북지역 착빙설 하중조건 검토 (A study on the ice and snow loading condition in Taebaek and Sabuk area in Gangwon province for the construction of KEPCO 765kV transmission lines)

  • 박광희;김용완;원봉주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1923-1924
    • /
    • 1996
  • Some part of the route in KEPCO 765kV transmission line being constructed passes through a high mountain area which is 800m above the sea level (Taebaek, Sabuk area in Gangwon province). This area is the top part of Taebaek mountains corresponding to the backbone of korean peninsula and has lots of snow during the winter season because the winter seasonal wind gone up along the mountainside of Taebaek Mts. meets open air of the East sea. KEPCO has experienced 63 faults of T/L between 1968 and 1993 in this area, which is a very serious problem. Especially 154kV Hwang-Ji T/L fault in 1990, 2 was a unprecedented case which needs to be analyzed carefully to take proper measures. After reviewing ice and snow loading conditions and analyzing the fault of Hwang-Ji T/L, we're going to determine the revisement of ice and snow loading condition in this area to increase reliability of 765kV transmission line.

  • PDF

Atomic Layer Deposition (ALD) of ZrO2 in Ultrahigh Vacuum (UHV)

  • Roy, Probir Chandra;Jeong, Hyun Suck;Doh, Won Hui;Kim, Chang Min
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1221-1224
    • /
    • 2013
  • The atomic layer deposition (ALD) of $ZrO_2$ was conducted in ultrahigh vacuum (UHV) conditions. The surface was exposed to $ZrCl_4$ and $H_2O$ in sequence and the surface species produced after each step were identified in situ with X-ray photoelectron spectroscopy (XPS). $ZrCl_4$ is molecularly adsorbed at 140 K on the $SiO_2$/Si(111) surface covered with OH groups. When the surface is heated to 300 K, $ZrCl_4$ loses two Cl atoms to produce $ZrCl_2$ species. Remaining Cl atoms of $ZrCl_2$ species can be completely removed by exposing the surface to $H_2O$ at 300 K followed by heating to 600 K. The layer-by-layer deposition of $ZrO_2$ was successfully accomplished by repeated cycles of $ZrCl_4$ dosing and $H_2O$ treatment.

A Study on the Negative Differential Resistance in Dipyridinium Self-Assembled Monolayers Using STM

  • Lee Nam-Suk;Shin Hoon-Kyu;Kwon Young-Soo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권3호
    • /
    • pp.111-114
    • /
    • 2005
  • Organic monolayers were fabricated onto Au(l l l) substrate by self-assembly method using dipyridinium. Also, organic single molecule in the organic monolayers was selected to measure the current-voltage (I-V) curves by using the ultrahigh vacuum scanning tunneling microscopy (UHV-STM). The organic molecule used in the experiment was dipyridinium dithioacetate, which contains thiol functional group and can be self-assembled easily onto Au(l l l) substrate. The concentration of dipyridinium dithioacetate for self-assembly procedure was I [mM/L]. To confirm the formation of self-assembled mono layers (SAMs), the differences of thickness of the self-assembled organic monolayers were observed by using an ellipsometer, and the morphology and I-V curves of the SAMs were investigated by using UHV-STM. The applied voltages were from -2 [V] to +2 [V], temperature was 300 [K]. The vacuum for measuring current of the organic single molecule was 6 $\times$ 10$^{-8}$ [Torr]. As a result, properties of the negative differential resistance (NDR) in constant voltage were found.

Wind load characteristics and effects of 1000kV UHV substation frame based on HFFB

  • Hao Tang;Fanghui Li;Xudong Zhi;Jie Zhao
    • Wind and Structures
    • /
    • 제38권6호
    • /
    • pp.477-492
    • /
    • 2024
  • This study presents a comprehensive investigation of wind load characteristics and wind-induced responses associated with different wind incidence angles and terrains of the 1000kV UHV substation frame. High-frequency force balance (HFFB) force measurement wind tunnel tests are conducted on the overall and segment models to characterize wind loads characteristics such as the aerodynamic force coefficients and the shape factors. The most unfavorable wind incidence angles and terrains for aerodynamic characteristics are obtained. A finite element model of the substation frame is built to determine the wind-induced response characters based on the aerodynamic force coefficients and bottom forces of the segment models. The mean and root mean square (RMS) values of displacement responses at different heights of the frame structure are compared and analyzed. The influence of wind incidence angle and terrains on wind-induced responses is also examined. The displacement responses in terms of the crest factor method are subsequently transformed into dynamic response factors. The recommended values of dynamic response factors at four typical heights have been proposed to provide a reference for the wind resistance design of such structures.