• Title/Summary/Keyword: UHF system

Search Result 275, Processing Time 0.047 seconds

Auto Sushi Conveyer-Belt Payment System Using UHF RFID Dishes (UHF RFID 접시를 사용한 자동회전초밥 자동결제시스템)

  • Nam, Seahyeon;Yim, Yongho;Jung, Haeyong;Seok, Juwan;Chung, You Chung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.12
    • /
    • pp.1225-1229
    • /
    • 2014
  • This paper introduces a development of the auto sushi conveyer-belt payment system using UHF RFID dishes. In a sushi bar, instead of counting the number of the finished sushi dishes, sushi dishes with the UHF RFID have been used in the auto payment system to have accuracy and convenience. To recognize each dish, the UHF RFID tag has been designed, and auto-payment system has been developed. The UHF RFID tag under the dish has been recognized by an RFID reader, and the auto RFID payment system shows the total price of the finished dishes based on the color and number of dishes automatically. The performance of the developed UHF RFID tag and auto RFID payment system have been measured and verified.

A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS) (가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법)

  • Gu, Seon-Geun;Park, Gi-Jun;Yun, Jin-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

A Study on Development of UHF RFID R/W Using AT91SAM7S256 (AT91SAM7S256을 이용한 UHF RFID R/W 전용 단말기 개발에 관한 연구)

  • Hwang, Gi-Hyun;Jang, Wan-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1301-1307
    • /
    • 2008
  • In this paper, we developed UHF RFID R/W system using AT91SAM7S256(ARM chip), UHF RFID R/W module (WJ7090) and wireless LAN(IEEE 802.11.a/b). And we developed a transmission/receiving packet which is send to UHF R/W module in AT91SAM7S256. In order to show the usefulness of UHF RFID R/W system, we executed a performance test. The developed UHF RFID R/W system shows better performance for reading of RFID tag and data transmission through wireless LAN.

Development of UHF RFID R/W System Using AT91SAM7S256 ARM Chip (AT91SAM7S256 ARM 칩을 이용한 UHF RFID R/W 단말기 개발)

  • Hwang, G.H.;Jang, J.W.;Han, H.L.;Son, J.H.
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1131-1132
    • /
    • 2008
  • In this paper, we developed UHF RFID R/W system using AT91SAM7S256(ARM chip), UHF RFID R/W module (WJ7090) and wireless LAN(IEEE 802.11.a/b). And we developed a transmission/receiving packet which is send to UHF R/W module in AT91SAM7S256. In order to show the usefulness of UHF RFID R/W system, we executed a performance test. The developed UHF RFID R/W system shows better performance for reading of RFID tag and data transmission through wireless LAN.

  • PDF

Military Entrance Control System Using Military Insignia UHF RFID Tags (군 계급장 UHF RFID 태그를 이용한 군 보안출입관리 시스템)

  • Nam, Seahyeon;Chung, You Chung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.11
    • /
    • pp.966-971
    • /
    • 2013
  • This paper introduces development of a Military Entrance Control System using the developed military insignia UHF RFID tags. Generally, in the military entrance control system, the security identification (ID) card with HF RFID tag can be used, to increase the security level, the developed insignia UHF RFID tags are used in the enforced military entrance control system. The general metal insignias, have been worn on a hat or on the shoulder pads of a military uniforms, are simulated and developed as UHF RFID insignia tags. The military entrance control system can manage the name, rank, address (information of military personnel), time and date of entrance and the history of entrance of the security area.

Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability (부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

On-line PD Monitoring Using UHF Technique (UHF 가술을 이용한 온라인 PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.115-118
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers. is designed, which has been installed inside the oil tank of a transformer by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

DEVELOPMENT OF UHF SENSOR FOR PARTIAL DISCHARGE DIAGNOSIS OF POWER TRANSFORMER (전력변압기 부분방전 진단을 위한 UHF 센서 개발)

  • Ryu, Eun-Tae;Hwang, Kyung-Rok;Jung, Jae-Ryong;Yang, Hang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1556-1557
    • /
    • 2011
  • 변압기의 고체 절연이 열화 되거나 불순물 및 수분이 혼입되어 임계치 이상의 고전계가 인가되면 결합부분에서 부분방전이 발생한다. 현재 변압기에서 부분방전을 검출하기 위해서는 부싱탭을 이용하거나 전류센서, 초음파센서 등을 이용하여 부분방전을 검출하고 있지만 전기적인 부싱탭이나 전류센서를 이용한 검출 방법은 주변 잡음의 영향을 많이 받고 초음파법은 감도가 낮다는 단점을 가지고 있다. 이에, UHF 방식을 이용한 부분방전 검출 기술이 전력기기의 초기 고장진단을 발견하는 효과적인 방법으로 인식되고 있다. 최근에는 이러한 UHF 진단방식의 높은 감도, 외부노이즈에 대한 적은 영향, 온라인 측정의 가능성의 장점으로 전력용 변압기에도 적용되고 있다. 본 논문에서는 전력 변압기에서 PD 진단에 적합한 UHF 센서의 개발에 대해서 소개한다. 제안된 UHF 센서는 광대역(500 ~ 1,500MHz)에서 측정이 가능하며 감도가 우수하며 특정 대역에서 공진점을 가지는 다중 공진 모노폴 안테나 타입이다. 안테나 시뮬레이션 및 해석을 통해 유중 부분방전을 모의하여 감도 측정을 실시한 결과 제안된 UHF 센서가 전력용 변압기의 부분방전 측정에서 높은 감도를 나타냈으며, 기존 측정 방식의 단점을 보완할 수 있는 방안으로서 전자파를 이용한 부분방전 측정에 대한 기초연구를 실시하여 변압기 운전중에 전자파 측정에 의한 부분방전 감시가 가능한 것으로 나타났다.

  • PDF

Performance Analysis of Passive UHF RFID based Object Localization under Various Reader Antenna Locations (리더 안테나 위치에 따른 수동형 UHF RFID 기반 위치인식 성능 분석)

  • Choi, Jae Sung;Son, Byung Rak;Kim, Ju-Gon;Lee, Dong Ha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.648-650
    • /
    • 2015
  • In this research, we investigate an influence of a reader antenna location in Passive UHF RFID system based Object localization. When the localization system uses stationary RFID reader system, the performances of the system are significantly varied depending on the deployed antenna conditions due to its external environment such as reflection by the ground and obstacles. In this research we deeply study the RF conditions and differentiation with various antenna location. According to the empirical results, the localization system shows the best performance, where the reader antenna locates 1.5m from the target area of interest.

  • PDF

Development of UHF RFID Ceramic Antenna Using HFSS (HFSS를 이용한 UHF RFID 세라믹 안테나 개발)

  • Hwang, Gi-Hyun;Cha, Kyung-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.1
    • /
    • pp.193-198
    • /
    • 2009
  • In this paper, we report the design of UHF RFID ceramic antenna using HFSS, one of the widely used RFID design tools. Of the developed antenna system, we analyze its Return Loss using HFSS and its characteristics using Smith Chart methodology. We built the ceramic antenna system based on the HFSS design, and analyzed its performance by measuring the impedence matching and gains using Network Analyzer. We attach the developed prototype to UHF RFID portable terminal, and performed distance measuring for five widely used types of RFID tags to verify the performance of our proposed antenna system.