• Title/Summary/Keyword: UFR

Search Result 36, Processing Time 0.03 seconds

On UFR Settings Considering Wind Power Fluctuation In Jeju Island (제주도 풍력발전기 출력변동성을 고려한 적정 UFR 차단방식 연구)

  • Park, Min-Su;Chun, Yeong-Han;Byun, Sung-Hyun;Yang, Jeong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.445-450
    • /
    • 2014
  • Jeju power system is connected to the mainland power system through HVDC, and receives about half of required electricity through the HVDC lines. Jeju power system already experienced black out when a generator tripped at the moment of the HVDC line faults. But, UFR operated as was expected when HVDC line fault occurred at that time. As the penetration level of wind turbines increases, it is required to set UFR again considering intermittent wind turbin outputs. In this paper, we address a new way of UFR setting through computer simulation.

The Design of UFR with Fast Frequency Measurement Technique (고속의 주파수 계측 알고리즘을 갖는 저주파 계전기 설계)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • In this paper, the frequency estimator and DFT filter gain compensation for UFR(Under Frequency protection Relay) is introduced. Due to the sudden appearance of generator loads or faults in power system, the frequency is supposed to deviate from its nominal value. Because a frequency calculation is based on phase information, it needs sufficient sampling data to figure out a precious frequency. Therefore the frequency measurement for UFR needs excellent qualities such as high speed and precision with low sampling frequency Authors propose the frequency estimator which compares the vector differences and the DFT filter gain compensation which identifies DFT filter error and correct it. Using the frequency estimator and compensation, UFR which has the 0.01[ms] calculation delay and 0.003[Hz] measurement error is implemented with digital processor.

생체 임피던스

  • 서병설
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.63-68
    • /
    • 1985
  • Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers.

  • PDF

Electrochemical Oxidation of Amoxicillin in Its Commercial Formulation on Thermally Prepared RuO2/Ti

  • Auguste, Appia Foffie Thiery;Quand-Meme, Gnamba Corneil;Ollo, Kambire;Mohamed, Berte;Sahi placide, Sadia;Ibrahima, Sanogo;Lassine, Ouattara
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.82-89
    • /
    • 2016
  • In this work, a ruthenium dioxide electrode has been prepared by thermal decomposition at 400 ℃ then used for the oxidation of commercial amoxicillin. The physical characterization showed that RuO2 electrode presents a mud cracked structure. Its electrochemical characterization has revealed an increase of the voltammetric charge in acid electrolyte compared to neutral electrolyte indicating the importance of protons in its surface redox processes. The voltammetric study of the oxidation of amoxicillin has been investigated. It has been obtained that the oxidation of amoxicillin is controlled by both adsorption and diffusion processes. Moreover, the oxidation of amoxicillin occurs via direct and indirect processes in free or electrolyte containing chlorides. Through preparative electrolysis, enhancement of amoxicillin oxidation was observed in the presence of chloride where the amoxicillin degradation yield reached more than 50 % compared to less than 5% in the absence of chlorides. Spectrophotometric investigations have revealed the degradation of intermediates absorbing at 350 nm.

In Vitro Evaluation of Reused Hollow Fiber Dialyzers

  • Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.245-252
    • /
    • 1992
  • Air pressure decay (APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those reused in patients several times. C-DAK 4000 (Cordis Dow) and CF 15-11 (Baxter Travenol) reused dialyzers obtained (rom the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAK dialyzers had a larger APD($11.70{\pm}1.32$mmHg/min) compared to CF dialyzers($4.32{\pm}0.55$mmHg/min) (p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHg/min)on the reused dialyzers(2 out of 40 CF and 5 out 26 C DAK) were attributed to the possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD Is a more son sitive test than UFR test to evaluate the integrity of the fibers.

  • PDF

New Approaches to Xerostomia with Salivary Flow Rate Based on Machine Learning Algorithm

  • Yeon-Hee Lee;Q-Schick Auh;Hee-Kyung Park
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.47-62
    • /
    • 2023
  • Purpose: We aimed to investigate the objective cutoff values of unstimulated flow rates (UFR) and stimulated salivary flow rates (SFR) in patients with xerostomia and to present an optimal machine learning model with a classification and regression tree (CART) for all ages. Materials and Methods: A total of 829 patients with oral diseases were enrolled (591 females; mean age, 59.29±16.40 years; 8~95 years old), 199 patients with xerostomia and 630 patients without xerostomia. Salivary and clinical characteristics were collected and analyzed. Result: Patients with xerostomia had significantly lower levels of UFR (0.29±0.22 vs. 0.41±0.24 ml/min) and SFR (1.12±0.55 vs. 1.39±0.94 ml/min) (P<0.001), respectively, compared to those with non-xerostomia. The presence of xerostomia had a significantly negative correlation with UFR (r=-0.603, P=0.002) and SFR (r=-0.301, P=0.017). In the diagnosis of xerostomia based on the CART algorithm, the presence of stomatitis, candidiasis, halitosis, psychiatric disorder, and hyperlipidemia were significant predictors for xerostomia, and the cutoff ranges for xerostomia for UFR and SFR were 0.03~0.18 ml/min and 0.85~1.6 ml/min, respectively. Conclusion: Xerostomia was correlated with decreases in UFR and SFR, and their cutoff values varied depending on the patient's underlying oral and systemic conditions.

An Implementation Study on a Low-cost High-accuracy Position Monitoring System for Unmanned Flying Robots (Embedded Linux 기반 무인비행로봇의 저가 고정밀 위치 모니터링 시스템 구현 연구)

  • Lim, Joonhoo;Kim, Hee Sung;Lee, Je Yong;Choi, Kwang Ho;Cho, Jeongho;Lee, Hyung Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.12
    • /
    • pp.1196-1203
    • /
    • 2014
  • Recently, UFRs (Unmanned Flying Robots) have begun to be utilized in various areas for civilian and military applications. Due to this increased utilization, accidents involving UFRsare also increasing. To prevent or monitor accidents caused by UFRs, high-accuracy positioning information is one of the most important technical elements. This paper proposes an efficient UFR monitoring system which provides accurate UFR positioning information with low-cost onboard elements; a small ARM module based on an embedded Linux operating system, a low-cost single frequency GPS receiver with a cheap patch antenna, and a versatile wireless network interface module. The ground monitoring system employs a dual frequency GPS receiver to generate exact UFR coordinates with cm-level accuracy. By processing the UFR measurements based on the Inverse RTK (Real Time Kinematic) method, the ground monitoring system determines the cm-level accurate coordinates of the UFR. The feasibility of the proposed UFR monitoring system was evaluated by three experiments in terms of data loss and accuracy.

Study of ball bearing fatigue damage using vibration analysis: application to thrust ball bearings

  • Yessine, Toumi M.;Fabrice, Bolaers;Fabien, Bogard;Sebastien, Murer
    • Structural Engineering and Mechanics
    • /
    • v.53 no.2
    • /
    • pp.325-336
    • /
    • 2015
  • This paper presents a study based on the damage due to the fatigue life of thrust ball bearings using vibratory analysis. The main contribution of this work lies in establishing a relation between modal damping and the rolling contact fatigue damage of the thrust ball bearing. Time domain signals and frequency spectra are extracted from both static and dynamic experiments. The first part of this research consists in measuring the damping of damaged thrust ball bearings using impact hammer characterization tests. In a second part, indented components representing spalled bearings are studied to determine the evolution of damping values in real-time vibration spectra using the random decrement method. Dynamic results, in good agreement with static tests, show that damping varies depending on the component's damage state. Therefore, the method detailed in this work will offer a possible technique to estimate the thrust ball bearing fatigue damage variation in presence of spalling.

A study one the exercise preparing for a wide area outage from UFR in the main land power system using DTS (차세대 DTS를 활용한 육지계통 UFR 동작 광역정전 발생 대응 모의훈련에 대한 고찰)

  • Jung, Chang-Hyun;Kim, Tae-kyun;Lee, Ik-jong;Ha, Chul;Park, Jae-geun;Lee, Young-gui
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.227-228
    • /
    • 2015
  • DTS(Dispatcher Training Simulator)는 EMS(Energy Management System) 전력계통 모델을 기반으로 off-line 환경에서 운영되는 급전원 훈련용 시뮬레이터이다. 전력거래소 중앙전력관제센터는 DTS를 이용하여 다양한 상황별 고장복구 훈련을 시행하고 있으며, 계통 검토 검증에도 활용하고 있다. 본 논문은 DTS를 활용하여 육지계통 UFR 동작과 광역정전 발생을 모의하고, 그에 따른 전력계통 변화와 정상운영 조치 시뮬레이션 결과에 대해 소개하고자 한다.

  • PDF

UGR Detection and Tracking in Aerial Images from UFR for Remote Control (비행로봇의 항공 영상 온라인 학습을 통한 지상로봇 검출 및 추적)

  • Kim, Seung-Hun;Jung, Il-Kyun
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.2
    • /
    • pp.104-111
    • /
    • 2015
  • In this paper, we proposed visual information to provide a highly maneuverable system for a tele-operator. The visual information image is bird's eye view from UFR(Unmanned Flying Robot) shows around UGR(Unmanned Ground Robot). We need UGV detection and tracking method for UFR following UGR always. The proposed system uses TLD(Tracking Learning Detection) method to rapidly and robustly estimate the motion of the new detected UGR between consecutive frames. The TLD system trains an on-line UGR detector for the tracked UGR. The proposed system uses the extended Kalman filter in order to enhance the performance of the tracker. As a result, we provided the tele-operator with the visual information for convenient control.