• 제목/요약/키워드: U-type test

검색결과 391건 처리시간 0.026초

집성재의 정거길이가 휨강도성능에 미치는 영향 (The Effect of Finger Length on Bending Strength Properties in Laminated Wood)

  • 홍병화;변희섭;김종만
    • 한국가구학회지
    • /
    • 제11권2호
    • /
    • pp.7-12
    • /
    • 2000
  • This paper describes the bending strength properties of laminated woods which had three kinds of specimens according to finger length-12, 4.5 mm and butt joint and the acoustic emissions (AEs) generated during the test. 3-ply laminated wood beams were tension side layers (lower layers) composed of one middle lamina and two side-jointed laminae, with one butt joint ($_1BJ$), one finger joint (12mm, $_1FJ_{12}$) or one finger joint (4.5mm, $_1FJ_{4.5}$) in the middle lamina of tension side layer. And 3-ply laminated wood beams were tension side layers (lower layers) also composed of one lamina, with one butt joint (BJ), one finger joint (12mm, $FJ_{12}$) or one finger joint (4.5mm, $FJ_{4.5}$/) in tension side layer. Cryptomelia pieces were cut for butt and two finger types and glued with resorcinol-phenol resin adhesive. The results were as follows It was not effective in the bending modulus of elasicity (MOE) with IFJL type and had no difference from finger length. The bending modulus of rupture (MOR) of laminated wood beams including finger joint was the same values as that including butt feint and had no difference from finger length. It was effective in MOE with FJL type and had no difference from finger length. The effect of finger joint on MOR was much higher than that of butt joint but had no difference from finger length. The AE generation time of IFJL type was earlier than that of the control wood and the number of AE count was much more than that of the control wood. However, the AE generation time of FJL type was earlier than that of the control wood and the number of U count was much fewer than that of the control wood.

  • PDF

Manta형 무인잠수정의 대각도 받음각을 갖는 조종운동 수학모델에 관한 연구 (A Study on Mathematical Model of Manoeuvring Motion of Manta-type Unmanned Undersea Vehicle at Large Attack Angles)

  • 배준영;손경호;김준
    • 대한조선학회논문집
    • /
    • 제47권3호
    • /
    • pp.328-341
    • /
    • 2010
  • The authors adopt the Unmanned Undersea Vehicle(UUV), which has taken the shape of manta(Sohn et al. 2006). They call here it Manta-type Unmanned Undersea Test Vehicle(MUUTV). MUUTV is designed with the similar concept of UUV called Manta Test Vehicle(MTV), which was originally built by the Naval Undersea Warfare Center, USA(Lisiewicz and French 2000, Sirmalis et al. 2001, U.S. Navy 2004). The present study deals with evaluation of extreme motion of MUUTV at large attack angles. Extreme motion contains, for example, rising and depth change due to operation of hovering thrusters attached to MUUTV, lateral motion due to ocean current applied to MUUTV at low advance velocity, and so on. Numerical simulation technique has been utilized. The previous mathematical model on manoeuvring motion of MUUTV(Bae et al. 2009a) is basically adopted. Based on the results of present model experiment on extreme motion, the mathematical model is revised and supplemented in order to describe extreme motion. The hydrodynamic derivatives related to extreme motion are obtained from present model experiment and the other derivatives are referred to previous work(Bae et al. 2009a).

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;손국원
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.52-62
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.

초보간호사의 대인관계능력, 직무 스트레스, 스트레스 대처유형이 이직의도에 미치는 영향: 직무 스트레스를 중심으로 (Impact of Interpersonal Relationship Ability, Job Stress, and Stress Coping Type on Turnover Intention of Nurses in the Early Stage of their Careers: Focusing on Job Stress)

  • 정자용;김철규
    • 한국직업건강간호학회지
    • /
    • 제27권1호
    • /
    • pp.36-47
    • /
    • 2018
  • Purpose: This study aimed to examine the effects of interpersonal relationship ability, job stress, and stress coping type on the turnover intention of nurses in the early stage of their careers. Methods: Data were collected from 136 early stage nurses from two general hospitals and one tertiary hospital in Chungbuk province. An early stage nurse was defined as the nurse with a work experience of 3 to 36 months. The collected data were analyzed using independent t-test, one-way ANOVA, Mann-Whitney U test, Person's correlation coefficient, and stepwise multiple regression. Results: It was seen that turnover intention had a negative correlation with interpersonal competency (r=-.20, p=.020) and a positive correlation with job stress (r=.56, p<.001). Job stress due to work over load, inadequate compensation and working environment, interpersonal relationship ability, and length of clinical career were significant factors influencing turnover intention (p<.05). These variables explained for 50.4% of the variance in turnover intention. Conclusion: It is necessary to develop an interpersonal relationship ability improvement program to decrease turnover intention among early stage nurses by helping them to successfully adapt to their job. Moreover, it is important to bring about continuous improvements in terms of provision of adequate workload and appropriate rewards, and creation of a suitable work environment to reduce the job stress of early stage nurses.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

Prevalence and Genotype Distribution of Human Papillomavirus Infections in Women Attending Hospitals in Chaozhou of Guangdong Province

  • Chen, Qiang;Luo, Zhao-Yun;Lin, Min;Lin, Qi-Li;Chen, Chan-Yu;Yang, Chun;Xie, Long-Xu;Li, Hui;Zheng, Jia-Kun;Yang, Li-Ye;Ju, Gui-Zhi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1519-1524
    • /
    • 2012
  • Background: Human papillomavirus (HPV) infection is the main cause of cervical cancer. Limited epidemiologic data of HPV prevalence are available for women attending hospitals in southern China. This study aimed to evaluate the profiles of HPV infection and cytology status in gynecological outpatients in Chaozhou City. Methods: A total of 2833 eligible women were enrolled. The HPV GenoArray test was used for HPV detection and genotyping. Nearly one half of the HPV positive women received liquid-based cytology test. Logistic regression analysis was performed to assess the predictable effects of age and genotype for categories of abnormal cytology. Results: The prevalence of overall, high-risk, and low-risk HPV infection were 24.5%, 19.5% and 8.4%, respectively. A U-shaped age-specific prevalence curve was observed in overall HPV and high-risk HPV, but not in low-risk HPV, which declined with age increasing. The 6 most common high-risk HPV type in descending order, were types 52, 16, 58, 18, 68, and 33. Age and HPV genotype were both important determinants of abnormal cytology incidence, the older women (>45 years) and those infected with HPV type 16 and/or 18 having the highest risk for abnormal cytology. Conclusion: Our findings support the hypothesis that second-generation HPV prophylactic vaccines including HPV-52 and -58 may offer higher protection for women residing in Chaozhou and neighboring cities in Guangdong.

Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision

  • Jeon, Jin-Hun;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.468-473
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by $10^{\circ}-20^{\circ}$ and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (${\alpha}=.05$). RESULTS. Precision discrepancies for the canine, premolar, and molar were $3.7{\mu}m$, $3.2{\mu}m$, and $7.3{\mu}m$, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were $6.2{\mu}m$, $11.2{\mu}m$, and $21.8{\mu}m$, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

프리캐스트 바닥판의 자기부상열차 가이드웨이 시스템 적용성 평가 : 정적 성능 실험 (Applicability Evaluation of Precast Deck to the Maglev Guideway System : Static Performance Test)

  • 진병무;김인규;김영진;이윤석;마향욱;오현철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.985-988
    • /
    • 2008
  • 자기부상열차는 궤도 위에 부상하여 운행하는 시스템이다. 자기부상열차의 특성상 주행 중 부상공극을 일정하게 유지하는 것이 사용성 및 승객의 승차감 면에서 매우 중요하다. 이 연구는 2006년 출범한 도시형 자기부상열차 실용화 사업단의 3-1 세부과제 선로구축물 성능개선 과제의 협동연구과제로 자 기부상열차교량 상부구조의 급속시공법 개발을 목표로 연구를 수행하였다. 현재 도로교에서 프리캐스트 바닥판은 품질, 공기 면에서 현장타설 바닥판에 비해 우수하며, 널리 사용되고 있다. 따라서, 연구진은 3-1세부과제의 주관기관인 한국철도기술연구원과 협업을 통하여 1차년도에 PSC-U형 거더 및 개구제형 강재 거더에 프리캐스트 바닥판을 적용하여 자기부상열차 가이드웨이의 기본 시스템을 제안한 바 있다. 이 연구에서는 프리캐스트 바닥판과 체일 체결구조의 구조안전성 검토를 목적으로 실대형 요소실험체를 제작, 이들 실험체의 사용하중 상태 및 극한하중 상태의 정적성능평가 실험을 수행하였다.

  • PDF

Trends in statistical methods in articles published in Archives of Plastic Surgery between 2012 and 2017

  • Han, Kyunghwa;Jung, Inkyung
    • Archives of Plastic Surgery
    • /
    • 제45권3호
    • /
    • pp.207-213
    • /
    • 2018
  • This review article presents an assessment of trends in statistical methods and an evaluation of their appropriateness in articles published in the Archives of Plastic Surgery (APS) from 2012 to 2017. We reviewed 388 original articles published in APS between 2012 and 2017. We categorized the articles that used statistical methods according to the type of statistical method, the number of statistical methods, and the type of statistical software used. We checked whether there were errors in the description of statistical methods and results. A total of 230 articles (59.3%) published in APS between 2012 and 2017 used one or more statistical method. Within these articles, there were 261 applications of statistical methods with continuous or ordinal outcomes, and 139 applications of statistical methods with categorical outcome. The Pearson chi-square test (17.4%) and the Mann-Whitney U test (14.4%) were the most frequently used methods. Errors in describing statistical methods and results were found in 133 of the 230 articles (57.8%). Inadequate description of P-values was the most common error (39.1%). Among the 230 articles that used statistical methods, 71.7% provided details about the statistical software programs used for the analyses. SPSS was predominantly used in the articles that presented statistical analyses. We found that the use of statistical methods in APS has increased over the last 6 years. It seems that researchers have been paying more attention to the proper use of statistics in recent years. It is expected that these positive trends will continue in APS.

방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구 (Study of Radiation Mapping System for Water Contamination in Water System)

  • 나원경;김한수;연제원;이레나;하장호
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.