• Title/Summary/Keyword: U-beam

Search Result 481, Processing Time 0.045 seconds

Mechanistic Analysis Modeling for the 3-D Chip Formation Process (3-D 칩생성과정의 역학적 해석 모델링)

  • Kim, Gyeong-U;Kim, U-Sun;Kim, Dong-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.163-168
    • /
    • 2000
  • Once the chip has developed a mixed mode of side-curl and up-curl, it would generally curl to strike the tool flank. The development of the bending stresses and sheat in the chip would ultimately lead to chip failure. This paper approach this problem from a mechanics-based approach, by treating the chip as a 3-D elastic curved beam, and applying appropriate constraints and forces. The expressions for bending, shear and direct stresses are developed through an energy-based criterion. The location of the maximum stresses is also identified and explained for simulated test conditions.

  • PDF

Generation of U and P Singularities in Partially Coherent Beams Using Intensity Control

  • Peng, Xinyu;Ye, Dong;Zheng, Guo;Zhao, Qi;Song, Minmin
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.85-89
    • /
    • 2017
  • It is shown that polarization singularities of a new type, namely U and P singularities, arise at the transverse cross section of a partially coherent beam, instead of the common singularities such as C points and L lines in a completely coherent vector field. A relationship between the two kind of singularities with respect to intensity is proposed. We also present a setup that can generate the new singularities, and any desired distribution of degree of polarization, using intensity control.

Strengthening of RC beams with prefabricated RC U cross-sectional plates

  • Demir, Ali;Tekin, Muhammed;Turali, Tezcan;Bagci, Muhiddin
    • Structural Engineering and Mechanics
    • /
    • v.49 no.6
    • /
    • pp.673-685
    • /
    • 2014
  • The topic of this study is to strengthen cracked beams with prefabricated RC U cross-sectional plates. The damaged beams were repaired by epoxy based glue. The repaired beams were strengthened using prefabricated plates. The strengthening plates were bonded to the bottom and side faces of the beams by anchorage rods and epoxy. The strengthened beams were incrementally loaded up to maximum load capacities. The experimental results were satisfactory since the load carrying capacities of damaged beams were increased approximately 76% due to strengthening. It was observed that strengthening plates had a dominant effect on the performance of beams in terms of both the post-elastic strength enhancement and the ductility. The experimental program was supported by a three-dimensional nonlinear finite element analysis. The experimental results were compared with the results obtained from the beam modeled with ANSYS finite element program.

Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards (단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능)

  • Kim, Sejong;Park, Joo-Saeng
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.876-883
    • /
    • 2015
  • Han-green project, which pursues Korean style post and beam timber house with traditional construction technique of Han-ok, has been carried out in KFRI (Korea Forest Research Institute) since 2006. Recently, the improvement of its building energy performance was studied with energy-saving elements. This study was conducted to provide the insulation details of building envelopes in a post-beam timber house for recent enhanced insulation standards and following effect on building energy performance. The level of thermal transmittance (U-value) values of building envelopes was composed of two stages: present Korean insulation standards and passive house. To evaluate building energy performance, the building airtightness values of two stages was ACH50 = $3.0h^{-1}$ for common domestic timber house constructed recently, and ACH50 = $0.6h^{-1}$ for passive house. Consequently, four cases of the building energy performance according to the combination of U-value with airtightness were evaluated. The test house for evaluation was located in Seoul and its energy performance was evaluated with CE3 commercial building energy simulation program. The result showed that enhanced insulation from level I to II reduced $14kWh/(m^2{\cdot}a)$ of annual heating energy demand regardless of airtightness.

Analysis on the Flexural Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 휨 거동 분석)

  • Son, Guk-Won;Yu, Sung-Young;Lim, Cheol-Woo;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.56-66
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Seismic resistant test of anchored and welded steel plate connections manifested an average of 2.8 times increase in the maximum loading (average 591.8 kN) in comparison to unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.4% and 2.7%. An analytical study was performed while assuming the RC column on the right side and the vertical element of the reinforced PC panel to behave in completely composite manner and the RC column on the left side and PC panel to behave in completely non-composite manner when loading was exerted from upper right end of RC frame of specimen to its left side. It was found with the assumptions that the overall flexural behavior in principle agreed with the experimental result.

Wave Characteristic in the Axially Loaded Axial-Bending-Shear Coupled Composite Laminated Beams (축 방향 하중을 받는 인장-굽힘-전단이 연성된 복합재 적층보의 파동특성)

  • Jang, In-Joon;Lee, U-Sik
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2650-2652
    • /
    • 2011
  • The fiber reinforced composite materials have many advantages due to their high strength-to-density ratios. Thus they have been widely used in many industrial applications. As the wave propagation are closely related to dynamic analysis of structures, it is very important to predict them. This paper presents a wave propagation in the axially loaded axial-bending-shear coupled composite laminated beams which are represented by the Timoshenko beam models based on the first-order shear deformation theory.

  • PDF