• Title/Summary/Keyword: Type of mode III

Search Result 40, Processing Time 0.03 seconds

비틀림하의 복합원통에 있는 원주 표면균열에 대한 응력 확대 계수

  • Kim, Yeong-Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.151-157
    • /
    • 2000
  • Stress intensity factors for the circumferential surface crack of a long composite cylinder under torsion is investigated. The problem is formulated as a singular integral equation of the first kind with a Cauchy type kernel using the integral transform technique. The mode III stress intensity factors at the crack tips are presented when (a) the inner crack tip is away from the interface and (b) the inner crack tip is at the interface.

  • PDF

Micropolar thermoelastic medium with voids under the effect of rotation concerned with 3PHL model

  • Othman, Mohamed I.A.;Alharbi, Amnah M.;Al-Autabi, Al-Anoud M. Kh.
    • Geomechanics and Engineering
    • /
    • v.21 no.5
    • /
    • pp.447-459
    • /
    • 2020
  • This paper aims to investigate the effect of rotation on a micropolar thermoelastic medium with voids problem. The problem is assessed according to three-phase-lag model. The normal mode analysis used to obtain the analytical expressions of the considered variables. The non-dimensional displacement, temperature, Micro rotation, the change in the volume fraction field, and stress of the material are obtained and illustrated graphically. Comparisons are made with the results predicted by two theories; namely three- phase-lag model (3PHL) and Green-Naghdi theory of type III (G-N III). The considered variables were plotted for different values of the rotation parameter, the phase-lag of heat flux and the phase-lag of temperature. The numerical results reveal that the rotation and the phase-lag times significantly influence the distribution of the field quantities. Some particular cases of interest are deduced from the present investigation.

Comparison of Health Status and Mini Nutritional Assessment according to Self-esteem of Elderly in Care Hospital (요양병원 입원 노인의 자아존중감에 따른 건강상태와 간이영양상태 비교)

  • Kim, Eun-mi;Kwon, Jin
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.25 no.4
    • /
    • pp.631-642
    • /
    • 2015
  • The purpose of the study was to examine health status and mini nutritional assessment (MNA) according to self-esteem status of elderly in care hospital. The survey was carried out from $13^{th}$ to $31^{st}$ of September, 2014 in five care hospitals. Analysis was performed for 226 subjects. Evaluation criteria included demographics, clinical status, MNA, health-related quality of life (EQ-5D) and self-esteem. The SE I, SE II and SE III groups were divided by self-esteem scores. Data were analyzed one-way ANOVA, Duncan' multiple range test and Pearson's correlation using SPSS 15.0. Education level, religion, dental condition and medical endurance type were significantly different in all groups. Many elderly people were normal BMI ($20.94{\sim}21.67kg/m^2$). Self-esteem significantly increased in order of SE I, SE II and SE III. Mobility, usual activity and anxiety or depression were significantly different in all groups, and EQ-5D of SE II and SE III groups were significantly higher than that of SE I group. Comparison of MNA screening score in elderly patients was as follows : Score for food intake, psychological stress or acute disease, neuropsychological problems, pressure scores or skin ulcer, protein intake, mode of feeding, nutritional status and health status in SE I group were significantly lower than those of SE II and SE III groups. Mobility and drug intake of SE I group were significantly lower than those of SE III groups. Fruit and vegetable intake SE I group were significantly higher than those of SE II and SE III groups. MIS (Malnutrition Indicator Score) was significantly different among the SE I, SE II and SE III groups. We conclude that self-esteem score is positively correlated with protein intake, nutrition status, health status and MIS in elderly care hospital. To improve nutritional status of elderly in care hospitals, systematic nutrition management and self-esteem education program should be implemented.

A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy (압전방식초음파치석제거기의작업조건에따른치과주조용합금의삭제결손부 양상에 관한 고찰)

  • Kim, Young-Sung;Kim, Soo-Hwan;Kim, Won-Kyung;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.4
    • /
    • pp.385-390
    • /
    • 2009
  • Purpose: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. Methods: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. Results: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. Conclusions: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.

N,N'-Dimethylethylenediamine-N,N'-di-α-butyric Acid Cobalt(III) Complexes Utilizing Oxidation of Sulfur of S-Methyl-L-cysteine

  • Kim, Hyun-Jin;Youm, Kyoung-Tae;Yang, Jung-Sung;Jun, Moo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.6
    • /
    • pp.851-856
    • /
    • 2002
  • The Reaction of S-methyl-S-cysteine(L-Smc) with racemic $s-cis-[Co(demba)Cl_2]-1$ (Hydmedba = $NN'-dimethylethylenediamine-NN'-di-\alpha-butyric$, acid) yields ${\Delta}$-s-cis-[Co(dmedba)(L-Smc)] 2 with N, O-chelation. Oxidation of sulfur of 2 with $H_2O_2$ in a 1 : 1 mole ratio gives ${\Delta}$-s-cis[Co(dmedba)(L-S(O)mc)] 3 having an uncoordinated sulfenate group. Oxidation of sulfur of L-Sm with $H_2O_2in$ a 1: 1 mole ratio produces S-methyl-L-cysteinesulfenate (L-S(O)me) 5. Direct reaction of 1 with 5 in basic medium gives an N.O-chelated ${\Delta}$s-cis[Co(dmedba)(L-S(O)mc)-N.O], which turmed out be same as obtained by oxidation of 2, while an N, S-chelated ${\Delta}$-s-cis-[Co(dmedba)(S-S(O)mc)-N,O] complex 4 is obtained in acidic medium from the reaction of 1 with 5. This is one of the rare $[$Co^{III}$(N_2O_2-type$ ligand)(amino acid)] type complex preparations, where the reaction conditions determine which mode of N, O and N, S caelation modes is favored.

Anti-Plane Shear Behavior of an Arbitrarily Oriented Crack in Bonded Materials with a Nonhomogeneous Interfacial Zone

  • Chung, Yong-Moon;Kim, Chul;Park, Hyung-Jip
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.269-279
    • /
    • 2003
  • The anti-plane shear problem of bonded elastic materials containing a crack at an arbitrary angle to the graded interfacial zone is investigated in this paper The interfacial zone is modeled as a nonhomogeneous interlayer of finite thickness with the continuously varying shear modulus between the two dissimilar, homogeneous half-planes. Formulation of the crack problem is based upon the use of the Fourier integral transform method and the coordinate transformations of basic field variables. The resulting Cauchy-type singular integral equation is solved numerically to provide the values of mode 111 stress intensity factors. A comprehensive parametric study is then presented of the influence of crack obliquity on the stress intensity factors for different crack size and locations and for different material combinations, in conjunction with the material nonhomogeneity within the graded interfacial zone.

A Versatile Universal Capacitor-Grounded Voltage-Mode Filter Using DVCCs

  • Chen, Hua-Pin;Shen, Sung-Shiou
    • ETRI Journal
    • /
    • v.29 no.4
    • /
    • pp.470-476
    • /
    • 2007
  • In this paper, a versatile three-input five-output universal capacitor-grounded voltage-mode filter is proposed. The circuit employs two differential voltage current conveyors as active elements together with two grounded capacitors and four resistors as passive elements. The proposed configuration can be used as either a single-input five-output or three-input two-output. Unlike the previously reported works, it can simultaneously realize five different generic filtering signals: lowpass, bandpass, highpass, bandreject, and allpass. It still maintains the following advantages: (i) the employment of all grounded capacitors, (ii) no need to employ inverting-type input signals, (iii) no need to impose component choice, (iv) orthogonal control of the resonance angular frequency ${\omega}_o$ and the quality factor Q, and (v) low active and passive sensitivity performances.

  • PDF

Fatigue Strength Assessment of Spot-Welded Lap Joint Using Strain Energy Density Factor

  • Sohn, Ilseon;Bae, Dongho
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.44-51
    • /
    • 2001
  • One of the recent issues in design of the spot-welded structure such as the automobile body is to develop an economical prediction method of the fatigue design criterion without additional fatigue test. In this paper, as one of basic investigation for developing such methods, fracture mechanical approach was investigated. First, the Model I, Mode II and Mode III, stress intensity factors were analyzed. Second, strain energy density factor (S) synthetically including them was calculated. And finally, in order to decide the systematic fatigue design criterion by using this strain energy density factor, fatigue data of the ΔP-N(sub)f obtained on the various in-plane bending type spot-welded lap joints were systematically re-arranged in the ΔS-N(sub)f relation. And its utility and reliability were verified by the theory of Weibull probability distribution function. The reliability of the proposed fatigue life prediction value at 10(sup)7 cycles by the strain energy density factor was estimated by 85%. Therefore, it is possible to decide the fatigue design criterion of spot-welded lap joint instead of the ΔP-N(sub)f relation.

  • PDF

Multiple Regression Analysis to Determine the Reservoir Classification in the Empirical Area-Reduction Method (경험적 면적감소법을 위한 저수지 분류에 관한 연구)

  • 권오훈
    • Water for future
    • /
    • v.10 no.1
    • /
    • pp.95-100
    • /
    • 1977
  • The empirical area-reduction method by W.M. Borland and C.R. Miller and its revised procedure by W.T. Moody were made of fitting the area and storage curves to the Van't Hul distributions. It should be noted that the reservoir is classified into one of the four standard types on the basis of the topographical feature of the reservoir in application of the method. In other words, this method did not take into account several considerafble factors affecting the mode of sediment deposition, but only the shape of the reservoir as a governign factor. This is why the method occasionally creates ambiguity in classification and accordingly leads to unexpected mode of deposition. This paper describes a generating an formula to decide the standard classification of four types Van's Hul distributions, taking into consideration quantitatively sediment-loss percent and capacity-inflow ratio as well as the shape of the reservoirs by multiple regression analysis using the least square method to get a better fit to the design curves. The result is expressed as $Y=-1.95+55.8X_1+0.14X_2+0.12X_3$ in which the the values of Y locate the standard type I through type IV in the range from ten to forty with the interval of ten. The regression analysis was correlated well with the standard errors of estimate of around two except for the case of the type IV. This formula does not give big difference from the Borland's work in general sityation, but it demonstrates acceptable results, giving somewhat precise replys for the specific reservoirs. Its application to the Soyang Lake, one of the largest reservoirs in the country, defined clearly the type II, while the original method located it in the boundary of the type II and type III.

  • PDF

The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro (압전방식 초음파 치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Cha, Kuk-Bong;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.139-148
    • /
    • 2009
  • Purpose: Ultrasonic scalers have been widely used for removing biofilm which is considered as major etiologic factor of periodontal disease. The purpose of this study was to evaluate the effect of working parameters of piezoeletric ultrasonic scaler with scaler tip (No. 1 tip) on casting gold alloy removal. Methods: Type III dental casting gold alloy (Firmilay$^{circledR}$, Jelenko Inc, CA, USA) was used as substitute for tooth substance. Piezoeletric ultrasonic scaler and No.1 scaler tip (P-Max$^{circledR}$, Satelec, France) were selected. The selected working parameters were mode (P mode, S mode), power setting (2, 4, 8) and lateral force (0.5 N, 1.0 N, 2.0 N). The effect of working parameters was evaluated in terms of ablation depth, ablation width and ablation area. Results: Mode influenced ablation depth and ablation area. Power also influenced ablation depth and ablation area. Especially, Power 2 and power 8 showed statistically significant difference. Lateral force had influence on ablation width, and 0.5 N resulted significant increase compared with 1.0 N and 2.0 N. Ablation depth was influenced by mode, power and lateral force and defect width was influenced by lateral force. Ablation area was influenced by mode and power. Conclusions: It can be concluded that the use of piezoelectric ultrasonic scaler with No. 1 scaler tip in S mode and high power may result in significant loss of tooth substance.