• 제목/요약/키워드: Type of Installation

검색결과 1,522건 처리시간 0.031초

사고위치에 따른 분산전원 고립운전 상태 검출에 관한 연구 (The Study of Islanding State Detection of Distributed Generation Considering Fault Location)

  • 정승복;김재철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.107-109
    • /
    • 2003
  • This paper studies islanding detection distributed of distributed generation(DG). The study of islanding detection has been disconnected DG when power islanding was detected but fault type wasn't distingish. Nearby feeder fault the fault of feeder that not interconnected DG, is a little affect DG and distribution system. Therefore DG not need to disconnect distribution system. We studied islanding detection algorithm considering fault location.

  • PDF

하프 브릿지 병렬-직렬 공진형 컨버터의 주파수 특성에 관한 연구 (A Study On the Frequency Characteristic of the HBPSRC)

  • 차인수;박해암
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1992년도 추계학술발표회논문집
    • /
    • pp.51-55
    • /
    • 1992
  • By using the state plane approach, the steady state analysis and design of a half bridge parallel-series (LLC-type) resonant converter (HBPSRC) operating in the continous conduction made is presented. The state-plane diagram representation of the converter response gives good insight into the converter operation. Based on this analysis, a set of steady state characteristic waves for HBPSRC is presented. A simple design procedure is given and design example for a 100watts, 30KHz HBPSRC is presented for illustrative purposes.

  • PDF

프레온 냉동장치의 과열도에 관한 성능 특성 연구 (열교환기 타입별 비교) (The Study on Performance Characteristics due to the Degree of Superheat in Freon Refrigerating System (The Comparison of Heat Exchanger Types))

  • 정송태;하경수;김양현;박찬수;하옥남;이승재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.486-491
    • /
    • 2005
  • Nowadays heat exchangers that have been applied for freon refrigerating systems, a shell and tube type condenser, but because of their large size, large space for installation and more amount of refrigerants are needed. Therefore, in this study, we will find the most suitable operating condition through the comparison of performance between the shell & tube type and shell & disk type heat exchanger with R22. The experiments are carried out for the condensing pressure of refrigeration system from 1500kPa to 1600kPa and for the degree of superheat from 0 to $1^{\circ}C$ at each condensing pressure. As a result of experiment, if the shell & disk type heat exchanger is applied for R22 refrigerating systems, minimized input of refrigerants and space required for installation will be secured, which will have a great contribute to financial improvement for industry.

  • PDF

주사바늘 전극형 오존발생기 특성 연구 (Observation and Characteristics of Ozonizer using Injection Needle Electrode)

  • 박현미;권영학;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.77-82
    • /
    • 2015
  • Ozone is a powerful disinfectant and oxidizing agent, and it is used in a wide range of applications, such as waste water treatment, food processing, etc.. There is also a great potential of using ozone in new emerging medical applications, such as ozone dentistry and ozone oxygen therapy. For these purposes, simple, small, compact and efficient sources of ozone are needed. In this study, in order to increase the current-voltage range of the discharge and to avoid the overheating of the gas in the ozonizer we suggested ozonizer of injection needle and plate electrode type(INP Type) with the gas through the needle. A ozonizer of INP type have been investigated by focusing on ozone concentration and yield according to flow rates and Gap of two electrodes. The results of studies of ozone production for DC corona discharge in oxygen at atmospheric pressure about the ozonizer of INP type. The ozone concentration and the generation yield increased as the gap of two electrodes and gas flow were decreased. Also, when the gap of two electrodes and gas flow with no change, the ozone concentration and generation yield each have variation of direct proportion and inverse proportion with discharge voltage.

래피드스타트식 형광등에서의 전력절감 방안 (Energy Saving Method for the Rapid-Start Fluorescent Lamps)

  • 김훈;박영광
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.38-44
    • /
    • 1991
  • A new method for energy saving in the fluorescent lamps using rapid-start ballast was developed. Using this method, about 2 W of the power was saved. And for the measurement of the wattage and current in fluorescent lamp, circuits of the rapid-start type ballasts were analysed.

  • PDF

7-segment형 후막 EL소자와 구동회로 (Powder EL device with 7-segment type and Driving Circuit)

  • 이종찬;박대희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.60-63
    • /
    • 2000
  • In this paper, 7-segment was implemented using AC powder EL. ZnS:Cu and BaTiO3 was used as a phosphor and dielectric respectively. The preparation of phosphor and dielectric layer was performed with screen printing. The implemented system of 7-segment was divided as following; EL display, driving circuit, software for driving. The properties of fabricated devices was measured with EL spectrum and brightness.

  • PDF

광화학 램프를 이용한 오존응용특성 연구 (A study on the Characteristics of Ozone Application Using Photochemical Reaction Lamp)

  • 우성훈;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.423-425
    • /
    • 2008
  • In this paper, We have designed and manufactured a photochemical reaction lamp type ozonizer system which was applied to keep quality of herb medicines during storage. We used photochemical reaction lamp in a storage system, and investigated the sterilization characteristic. Also, we made research an ingredient and quality characteristic of herb medicines according to ozone storage.

  • PDF

콤팩트 형광램프의 전극구조에 대한 고찰 (A Study on Electrode Construction of Compact Fluorescent Lamp)

  • 신상욱;이세현;조미령;황명근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.149-154
    • /
    • 2004
  • In this paper, we observed an electrode structure that is an important element that decide life of compact fluorescent lamp. We measured winding and application type of electron emission material and electrode damage with SEM(Scanning Electron Microscope). From now on, we need to measure rather several difference aging-time sample than analyze a relation electrode between life

  • PDF

루프형 자계센서를 이용하여 뇌방전이 발생한 방향을 탐지하는 기법 (A Methodology of Finding the Direction of Lightning Discharge using Loop-type Magnetic Field Sensors)

  • 이복희;조치연;조성철
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.63-68
    • /
    • 2014
  • This paper deals with a methodology that applies the time-varying magnetic fields produced by the cloud discharges to find the direction of thunderstorm movement. We investigated the basic performance of the magnetic field measurement system composed of multi-turn loop-type sensors, the differential amplifier and active integrator. As a result, the response characteristics of the magnetic field sensor system to sinusoidal signals was excellent. The frequency bandwidth ranges from about 1 kHz to 500 kHz, the response sensitivity was 0.16mV/nT. In addition, we proposed the algorithm that determines the direction of lightning discharges using the comparison of the output signals of right-angled loop-type magnetic field sensors. The accuracy of the direction finding of lightning discharges is fairly well within the measurement error of less than $5^{\circ}$. The magnetic field measurement system proposed in this work can be used to track the direction of thunderstorm movement.

Faraday 효과를 이용한 광 전류 센서 (Optical Current Snesor using Faraday Effect)

  • 김수길
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.97-101
    • /
    • 2002
  • The optical current transformer using Faraday effect is the sensor to measure current that flows in any conductor. This sensor doesn't undergo the magnetic saturation and effect of adjacent conductors. But this senor using bulk-glass sensing element has crucial drawback. It is impossible that the sensor is mounted to conductor without breaking the closed-loop of light or conductor. So we developed the clamp-type optical current transformer and made an experiment.

  • PDF