A study on the performance of various BIPV modules applied in a real building demonstration (BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석)

  • Lee, Sang-Moon;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.53-63
    • /
    • 2016
  • Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of $45^{\circ}$ is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.

Analysis on the Effect of Local Climate on the Unit-type Ground Heat Exchanger (지역 기후가 유닛형 지중열교환기 성능에 미치는 영향)

  • Bae, Sangmu;Kim, Jae-Min;Nam, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.67-76
    • /
    • 2019
  • A ground source heat pump (GSHP) system can stable system operation by using underground heat source and has high reliability for energy production. However, wide-spread of the GSHP system is delayed to high initial investment costs. In previous studies, horizontal and unit-type ground heat exchanger (GHX) have developed to overcome disadvantages such as high initial cost. However, these performances of GHXs are greatly influenced by climate and weather conditions. It is necessary to analyze the performance of GHX according to the ground temperature change in the installation site. In this study, the ground temperature of each installation site confirmed and performance of unit-type GHX quantitatively analyzed by numerical analysis. As the result, the performance of the unit type GHX was 33.9 W/m in Seoul, 34.2 W/m in Daejeon, and 37.2 W/m in Busan.The result showed the difference performance of GHX according to local climate was maximum of 9.7%.

1MVA synchronous generator control for vessel used for digital AVR of drop method (Drop 방식의 디지털 AVR을 이용한 1MVA급 선박용 동기발전기 제어)

  • Yoo, Dong-Hwan;Hwang, Chun-Hwan;Park, Sang-Hoon;Yoo, Jae-Sung;Lee, Sang-Suk;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.225-229
    • /
    • 2007
  • The output voltage of a synchronous generator is regulated constantly by field current control of excitation system. Synchronous generator exciter has two type, first one is Drop control type by thyristor and second one is exciter current control type through power output by PWM control. Control method of the second one prevails, but when the power devices have a breakdown, output voltage of the generator rises rapidly. This exciter must have a protection circuit and system is complicated, so reliability is poor Excitation control type which is drop control type control only 10% of the power, so it can be improved precision. When a trouble come to the controller, output voltage of a generator don't rise excessively and the voltage rise about 10%, so it has a excellent reliability. This paper prove stability of the digital AVR.

  • PDF

A Study on the Efficiency of LED Lighting Applied by Direct AC Power Using Magnetic Resonance Wireless Power Transfer System (자계 공진 방식의 무선전력전송 장치를 이용한 교류 전력 직접 인가에 의한 LED 조명기기 효율에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.15-20
    • /
    • 2013
  • In this paper, wireless power transfer system using the magnetic resonance was designed and applied to LED lighting for implementation of wireless lighting. This lighting was made by the converted DC driving type and the direct AC driving type. In the former, transferred AC power was rectified into DC and regulated to the specified voltage value, which leads to produce the loss at the rectifying and regulating circuit. In the latter, wireless-transferred AC power was directly applied to LED, which get rid of the loss derived from the additional circuit. For the efficiency-comparison between the former and the latter, the power at each stage was measured when the same optical output radiated from LED lighting part. The result revealed that the direct AC driving type had 18% higher efficiency than the DC driving type and confirmed that LED lighting using magnetic resonance wireless power transfer system can be efficient by direct AC power supply. And the direct AC driving type had the simple circuit structure and the simple LED lighting formation, so this can leads to various application.

Analysis of Reduction Factors to Creep Deformation of Reinforced Geosynthetics

  • Jeon, Han-Yong;Yuu, Jung-Jo;Mok, Mun-Sung
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10a
    • /
    • pp.104-104
    • /
    • 2003
  • Geosynthetic Reinforcements - membrane drawn type, warp/knitted type, junction bonded type and composite type geogrids, strip type reinforcement - were used to compare the long-term perfor-mance by total factor of safety with reduction factors during service periods. To evaluate the reduction factors, wide-width tensile property, installation damage, creep deformation, chemical and biological degradation tests were performed. Long-term design strengths of geosynthetic reinforcements were calculated by using GRI standard Test Method GG4.

  • PDF

Characteristics of Sign Distribution in Underground Space (지하공간에 있어서 사인류의 분포특성)

  • Choi Ji-Sook;Yoo Hyun-Bae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1180-1187
    • /
    • 2006
  • We Studied the method of structuring the sign system for pedestrians in the underground space by investigating and analyzing the sign system at Tae-jon Underground Commercial Area in Korea by 1) classifying the signs by types and comparing their numder for each type in sections, 2) classiflying the signs by the points of installation, types, functions and contents of information and comparing their numbers, 3) classifying the signs by their height and comparing by the points of installation, and 4) classifying the signs by their points of installation finding patterns. As a result, we found out that the current pedestrian signs in Tae-jon Underground Commercial Area could by classified into those installted with a certain regularity and those concentrated in at certain points. We also found out that there were many problems with the current signs system. The big gap of the type and numble of the signs, concentration of the signs at the gate (entrance), and the big gap of the function of the signs by their points of installation. And the gap of the signs by the number of installation is big between the North side and the South side. Most of signs concentrated in the South side show the problems of installation attached by the types and quantity of information. We suggest that type of information has consistency by posting of signs, at the same time, the necessary information should be offered in order for the pedestrians to easily recognize as they more in the Underground space.

Experimental Study on the Load Sharing Ratio of G개up Pile (무리말뚝의 하중분담률에 관한 실험적 연구)

  • Kwon Oh-Kyun;Oh Se-Bung;Kim Jin-Bok
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.51-58
    • /
    • 2005
  • In this study, the large scale model tests were executed to estimate the Load Sharing Ratio (LSR) of raft in a piled footing under various conditions. The conditions such as the subsoil type, pile length, pile spacing, away type and pile installation method etc. were varied in the pile loading tests about the free-standing group piles and a piled footing. As a result of this study, it was found that there was no difference in the load-settlement curves, resulting from the pile installation method and subsoil type. The piles supported most of the external load until a yielding load of the piled footing, but the raft supported a considerable load after a yielding load. As the relative density of sands increased, the LSR decreased. As the pile spacing was wider and the pile length increased, there was a tendancy for the LSR to increase. But it was also found that the LSR was not affected by the pile installation method and the subsoil type.

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

A Study on the Application of Skirt Plates on Jacket Support Structures of Offshore Wind Turbines

  • Choi, Byeong-Ryoel;Choi, Han-Sik;Jo, Hyo-Jae;Lee, Sang-Hyep;Park, Young-Ho
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.2
    • /
    • pp.47-52
    • /
    • 2018
  • The Korea Offshore Wind Power (KOWP) is planning to construct offshore wind energy farms with an overall rated power of 2.5 GW in the south-western coast of the country until 2019. Various types of support structures for offshore wind turbines have been proposed in the past. Nevertheless, in South Korea, jacket structures have in general, been applied as support structures for offshore wind turbines owing to the many accumulated experiences and know-how regarding this kind of support structure. The choice of offshore structure is mainly influenced by site conditions such as seabed soil type and sea environment during installation. In installing jacket sets on the seabed, the mudmat is necessary to maintain the equilibrium of the jacket without the aid of additional devices. Hence, this study proposes the installation of skirt plates underneath the bottom frame of jackets in order to improve the installation stability of jacket structures under rougher sea conditions. To confirm the effect of skirt plates, installation stability analyses considering overturning, sliding and bearing capacity have been performed. From the results, it is shown that jacket structures with skirt plates can contribute to improving the sliding stability of the structures of new wind power farms, while providing economic benefits.

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.