• 제목/요약/키워드: Type C

검색결과 15,795건 처리시간 0.053초

GaSb결정 성장과 특성에 관한 연구 (A study on the characteristics and crystal growth of GaSb)

  • 이재구;오장섭;정성훈;송복식;문동찬;김선태
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권9호
    • /
    • pp.885-890
    • /
    • 1996
  • Undoped p-type and Te doped n-type GaSb crystals were grown by the vertical Bridgman method. The lattice constant of the GaSb crystals was 6.096.+-.000373.angs.. The carrier concentration, the resistivity, and the carrier mobility measured by the van der Pauw method were p.iden.8*10$^{16}$ c $m^{-3}$ , .rho..iden.0.20 .ohm.-cm, .mu.$_{p}$ .iden.400c $m^{2}$ $V^{-1}$ se $c^{-1}$ for p-type, n.iden.1*10$^{17}$ c $m^{-3}$ , .rho..iden.0.15 .ohm.-cm, .mu.$_{n}$ .iden.500c $m^{2}$ $V^{-1}$ se $c^{-1}$ for n-type at 300K. In case of treatment with metal ion of R $u^{+3}$, P $t^{+4}$, the carrier concentration, resistivity and carrier mobility of the GaSb crystals were p.iden.2*10$^{17}$ c $m^{-3}$ , .rho..iden.0.08.ohm.-cm, .mu.$_{p}$ .iden.420c $m^{2}$ $V^{-1}$ se $c^{-1}$ for p-type, n.iden.2.5*10$^{17}$ c $m^{-3}$ , .rho..iden.0.07.ohm.-cm, .mu.$_{n}$ .iden.520c $m^{2}$ $V^{-1}$ se $c^{-1}$ for n-type respectively. GaSb crystals had a tendency to lower resistivity and higher mobility, for surface treatment with metal ion effectively diminished surface recombination centers.s.

  • PDF

실리콘 막을 이용한 페놀-물 혼합물의 투과 증발 분리 (Pervaporation Separation of Phenol-Water Mixtures by Using Silicone Membranes)

  • 임지원;손민영;이규호
    • 공업화학
    • /
    • 제5권5호
    • /
    • pp.772-778
    • /
    • 1994
  • 페놀-물 혼합 용액에 대하여 Type 1과 Type 2의 실리콘 막을 이용하여 30, 40, $50^{\circ}C$에서 투과 증발 분리 실험을 수행하였다. 이때 공급 원액의 페놀 농도는 500ppm부터 5wt%이었다. 실험 결과, Type 2막이 Type 1막보다 분리능력이 더 효율적이었다. 공급원액의 농도가 5wt%와 500ppm일 때, Type 2막을 이용하여 투과액의 페놀 농도가 각각 70wt%, 11wt%의 양호한 결과를 얻었다.

  • PDF

Constitutive Model of Tendon Responses to Multiple Cyclic Demands(I) -Experimental Analysis-

  • Chun, Keyoung-Jin;Robert P. Hubbard
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.1002-1012
    • /
    • 2001
  • The work reported here is an extensive study of tendon response to multiple cyclic tests including 3% constant peak strain level test (A-type test), 3% constant peak strain level test with two rest periods (B-type test), and 3∼4% different peak strain level test (C-type test). A sufficient number of specimens were tested at each type of the test to statistically evaluate many changes in response during testing and differences in response between each type of the test. In cyclic tests, there were decreses (relaxations) in the peak stresses and hysteresis, increases in the slack strains, and during lower peak strain level (3%) cyclic block after higher peak strain level (4%) cyclic block in the C-type tests. Considering the results of this study and those of the other study of multiple cyclic tests with rest periods by Hubbard and Chun, 1985, recovery phenomena during the rest periods occurred predominantly at the beginning of the rest periods. Consistently in both studies, the effects of rest periods were small and transient compared to the effects of the cyclic extensions. The recovery with cycles at lower peak strain level (3%) after higher peak strain level (4%) in the C-type test has not been previously documented. This recovery seems to be a natural phenomena in tissue behavior so that collagenous structures recover during periods of decreased demand.

  • PDF

제2형 당뇨병 환자의 자가관리, 당화혈색소 및 주관적 건강상태 (A Study on Self Management, Hemoglobin A1c (HbA1c), and Perceived Health Status for the Type II Diabetes Patients)

  • 박주영
    • Journal of Korean Biological Nursing Science
    • /
    • 제12권2호
    • /
    • pp.106-113
    • /
    • 2010
  • Purpose: This study is conducted to examine the relationship among self management, HbA1c, and perceived health status of type II diabetes patients in community health department. Methods: Data were collected from 93 type II diabetes patients who are registered at five community health center using comprehensive survey, modified self care behavior, blood glucose and HbA1c were assessed by nurses. The data was analyzed by the SPSS (14.0) computer program, and it included descriptive statistics, t-test, ANOVA, and pearson's correlation coefficient. Results: There was significant relationship between perceived health status and HbA1c (r=-.252, p=.015). There was significant relationship between self management and HbA1c (r=-.279, p=.007). Conclusion: In order to control blood glucose in the type II diabetes patients, it is necessary to develop supportive self management programs by considering perceived health status.

CST 승화법을 이용한 p-type 4H-SiC(0001) 에픽텍셜층 성장과 이를 이용한 MESFET 소자의 전기적 특성 (Epitaxial Layer Growth of p-type 4H-SiC(0001) by the CST Method and Electrical Properties of MESFET Devices with Epitaxially Grown Layers)

  • 이기섭;박치권;이원재;신병철
    • 한국전기전자재료학회논문지
    • /
    • 제20권12호
    • /
    • pp.1056-1061
    • /
    • 2007
  • A sublimation epitaxial method, referred to as the Closed Space Technique (CST) was adopted to produce thick SiC epitaxial layers for power device applications. In this study, we aimed to systematically investigate surface morphologies and electrical properties of SiC epitaxial layers grown with varying a SiC/Al ratio in a SiC source powder during the sublimation growth using the CST method. The surface morphology was dramatically changed with varying the SiC/Al ratio. When the SiC/Al ratio of 90/1 was used, the step bunching was not observed in this magnification and the ratio of SiC/Al is an optimized range to grow of p-type SiC epitaxial layer. It was confirmed that the acceptor concentration of epitaxial layer was continuously decreased with increasing the SiC/Al ratio. 4H-SiC MESFETs haying a micron-gate length were fabricated using a lithography process and their current-voltage performances were characterized. It was confirmed that the increase of the negative voltage applied on the gate reduced the drain current, showing normal operation of FET device.

격납용기 Type "C" 누설률시험 요건 최적화 (The Optimization for Type "C" LLRT Requirements of Containment Vessel)

  • 정남두;김재동;김인철
    • 한국압력기기공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.9-13
    • /
    • 2009
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS-56.8(1994) in Korea. Two methods, the make-up flow rate and the pressure decay, are used for LLRT. Though ANSI/ANS-56.8 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the test period for type "C" LLRT is differently applied to each NPPs. Therefore, this study presents a unified test criteria for data stabilization and test duration through experiments to improve the test reliability for type "C".

  • PDF

Characteristics and Clinical Course of Fusiform Middle Cerebral Artery Aneurysms According to Location, Size, and Configuration

  • Seo, Dongwook;Lee, Si Un;Oh, Chang Wan;Kwon, O-Ki;Ban, Seung Pil;Kim, Tackeun;Byoun, Hyoung Soo;Kim, Young Deok;Lee, Yongjae;Won, Yu Deok;Bang, Jae Seung
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권6호
    • /
    • pp.649-660
    • /
    • 2019
  • Objective : To analyze the angiographic features and clinical course, including treatment outcomes and the natural course, of fusiform middle cerebral artery aneurysms (FMCAAs) according to their location, size, and configuration. Methods : We reviewed the literature on adult cases of FMCAAs published from 1980 to 2018; from 25 papers, 112 FMCAA cases, for which the location, size, and configuration could be identified, were included in this study. Additionally, 33 FMCAA cases in our hospital were included, from which 16 were assigned to the observation group. Thus, a total of 145 adult FMCAA cases were included. We classified the FMCAAs according to their location (l-type 1, beginning from prebifurcation; l-type 2, beginning from bifurcation; l-type 3, beginning from postbifurcation), size (small, <10 mm; large, ${\geq}10mm$; giant, ${\geq}25mm$), and configuration (c-type 1, classic dissecting aneurysm; c-type 2, segmental ectasia; c-type 3, dolichoectatic dissecting aneurysm). Results : The c-type 3 was more commonly diagnosed with ischemic symptoms (31.8%) than hemorrhage (13.6%), while 40.9% were found accidentally. In contrast, c-type 2 was more commonly diagnosed with hemorrhagic symptoms (14.9%) than ischemic symptoms (10.6%), and 72.3% were accidentally discovered. According to location, ischemic symptoms and hemorrhage were the most frequent symptoms in l-type 1 (28.6%) and l-type 3 (34.6%), respectively. Most of l-type 2 FMCAAs were found incidentally (68.4%). Based on the size of FMCAAs, only 11.1% of small aneurysms were found to be hemorrhagic, while 18.9% and 26.0% of large and giant aneurysms were hemorrhagic, respectively. Although four aneurysms of the 16 FMCAAs in the observation group increased in size and one aneurysm decreased in size during the observation period, no rupture was seen in any case and there were no significant predictors of aneurysm enlargement. Of 104 FMCAAs treated, 14 cases (13.5%) were aggravated than before surgery and all the aggravated cases were l-type 1. Conclusion : While ischemic symptoms occurred more frequently in l-type 1 and c-type 3, hemorrhagic rather than ischemic symptoms occurred more frequently in l-type 3 and c-type 2. In case of l-type 1 FMCAAs, more caution is required in determining the treatment due to the relatively high complication rate.

식생체류지의 도시 강우유출수 처리효율 영향인자 조사 연구 (Investigation on the Factors Affecting Urban Stormwater Management Performance of Bioretention Systems)

  • ;;홍정선;김이형
    • 한국물환경학회지
    • /
    • 제33권1호
    • /
    • pp.1-7
    • /
    • 2017
  • 식생체류지는 도시 강우유출수 관리를 위한 저영향개발 및 그린인프라 기술이며, 개발이전의 상태를 최대한 유지하는 강우유출수 관리기술로 자연을 모방하면서 생태계의 다양성을 향상시키는 기술이다. 본 연구는 식생체류지의 물순환 능력과 비점오염물질의 저감효율에 영향을 끼치는 인자를 도출하기 위하여 4개의 식생체류지 시스템에 대하여 연구를 수행하였다. 2개의 식생체류지, 즉 Type A-C와 Type A-FC에는 국화와 매발톱꽃이 식재되었으며, Type B-A와 Type B-JM식생체류지에는 진달래 및 조팝나무와 같은 관목식물이 식재되었다. 연구결과 식생체류지의 유출저감, 저류량 및 오염물질 저감에 영향을 끼치는 인자로는 TV, 침투기작, 여과재의 두께와 식생 종류로 나타났다. Type B-A와 Type B-JM식생체류지 설계시에는 유출저감, 지하수 충진, 긴 체류시간과 첨두유출량 저감과 비점오염물질 저감을 고려하여 설계가 필요한 것으로 나타났다. 반면에 Type A-C와 Type A-FC 식생체류지 설계시에는 지하수 오염 저감을 중요하게 고려하여야 하는 것으로 나타났다.

비닐 하우스용 작업복 개발에 관한 연구 (A Study on Development of Work Wear for the Plastic House Workers)

  • 명지영;심현섭;최정화
    • 한국의류학회지
    • /
    • 제17권1호
    • /
    • pp.19-35
    • /
    • 1993
  • This study was designed to devise work wear for plastic house worker. It was carried out (1) research on the clothing actual condition through interviewings with plastic house worker and observations, (2) thermal manikin test to measure thermal resistance of experimental clothes and (3) clothing comparing test in the laboratory and in the plastic house. In the laboratory experiment, it was choosen general type (A) and new devised types (B, C) made of microporous fabric for experimental clothes. Experimental clothes were made of 6 combinations including 3 type work wears (A, B, C) and 2 type underwears (1, 2). In the plastic house experiment, it was choosen general types of A (without rest place) and B (with rest place), and devised type C (with rest place), which was appeared good effect in the laboratory experiment. The results were as followings. 1. Work environment of the plastic house in summer and winter was very different from the outer environment. Work motion in the plastic house was burden to the plastic house workers. 2. Plastic house workers had on the general type's work wear. 3. As a result of thermal manikin test, thermal resistance was appeared B1>B2>C2>C1>A1>A2 in orders. 4. In the laboratory experiment, experimental clothes A was appeared smaller burden than B, C. Effect of mesh underwear was not appeared in this study condition. In subjective sensation, experimental clothes C was lower vote than A. Therefore experimental clothes C was superior to A in subjective wearing sensation. 5. In the plastic house experiment, the experimental conditions with rest place were appeared smaller burden than without rest place. General type B was appeared more positive physiological reactions than devised type C but significances between two types was not appeared.

  • PDF

큰느타리버섯 포장형태에 따른 신선도에 미치는 영향 (Effect of trimming type and storage temperature after harvest on shelf life of Pleurotus eryngii)

  • 이윤혜;이한범;장명준;주영철;전창성
    • 한국버섯학회지
    • /
    • 제10권4호
    • /
    • pp.198-202
    • /
    • 2012
  • 큰느타리버섯의 소포장에 적합한 포장형태 및 저장온도에 따른 저장기간 중 품질변화를 분석한 결과, 중량감모율은 저장온도가 높거나 저장기간이 길수록 증가하였으며, $0^{\circ}C$저장시 배지부착여부에 따른 차이가 없었으나 $4^{\circ}C$저장에서는 저장기간 38일까지 배지 부착형에서 다소 높았다. 갓신장율은 $0^{\circ}C$저장시 배지부착개체형이 비교적 낮았으며, $4^{\circ}C$저장에서는 배지 부착여부에 따른 큰 차이 없이 저장기간이 길수록 증가하였다. 저온저장 후 상온에서 기간이 길수록 중량감모율은 증가하였으며, 갓신장율은 배지부착형은 증가하였으나, 배지제거형은 6일 이후에 감소하는 경향을 보였다. 저온 저장 후 상온에서의 신선도는 배지부착형이 배지제거형보다 길게 유지되었으며, 32일 저온저장처리가 상온에서 6일까지 판매가능한 신선도가 유지되었다.