• 제목/요약/키워드: Type 1

검색결과 49,030건 처리시간 0.062초

도심 오피스건물의 옥상녹화 조성 유형별 건물에너지 절감 비교 연구 (Comparative of Energy-Saving by Green Roof Type on Urban Office Building)

  • 김정호;권기욱;주창훈;윤용한
    • 한국환경과학회지
    • /
    • 제23권8호
    • /
    • pp.1437-1446
    • /
    • 2014
  • This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F > type B > type C > type D > type E in the order and in the case of peak loads heating type B > type F > type D > type E>type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual $CO_2$ emissions reductions of unapplied type A were analyzed on average 469.78 kg.

비가림시설의 효율적 형태 개발에 관한 기초 연구 (A Fundamental Study on the Development of Highly Efficient Models of Rain Shelter)

  • 손정익;김문기;권영삼;남상운;윤남균
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.32-42
    • /
    • 1995
  • 1. 시설형태별 온도분포는 Type 1의 경우 지붕의 환기구가 없기 때문에 중력환기는 거의 일어나지 않고, 풍력환기에만 의존하게 되므로 풍속이 약한 경우는 온도가 상승하였다. Type 2 및 Type 3는 지붕의 환기구를 통하여 중력환기가 일어나기 때문에 대체로 온도 분포도 균일한 편으로 나타났다. 2. 시설형태별 평면 광분포는 Type 1가 가장 높고 Type 2, Type 3순으로 나타났다. 즉 일사투과율에 의한 지면 일사 도달율과 직접적으로 관련되기 때문에 Type 1, Type 2, Type 3순으로 지면온도 상승에 영향을 주었다. 3. 환기모델과 열수지 모델을 도입하여 환기량 및 실내온도 변화를 구한 결과, 시설형태별 풍속의 변화에 따른 내외기온차 변화는 Type 1이 가장 크고 Type 2, Type 3순이었다. Type 1의 경우 다른 형태에 비하여 풍속이 1 ㎧로 증가하면 급격히 내외기온차가 감소하였다. 4. 실측치를 사용하여 모델에 의한 풍속변화에 따른 환기량의 변화를 추정한 결과, Type 3 및 Type 2가 상대적으로 Type 1보다 낮은 경향을 나타냈다. 5. 전체적으로 개량형인 Type 2 및 Type 3은 관행형인 Type 1보다 효율적이라고 판단된다. 특히, 성력화의 차원에서 보면 Type 3이 Type 2보다 월등히 우수하기 때문에 자연적인 강우차단 능력이 보장된다면 Type 3이 Type 2보다 효율적이라고 사료된다.

  • PDF

AE기법을 이용한 원통형 복합재의 핀 체결부 파괴거동 (Failure Behavior of Pin-jointed Cylindrical Composites Using Acoustic Emission Technique)

  • 윤성호;황영은;김찬규
    • 한국추진공학회지
    • /
    • 제16권4호
    • /
    • pp.9-15
    • /
    • 2012
  • 본 연구에서는 핀 하중 시험을 통해 탄소섬유/에폭시 복합재의 핀 체결부에 대한 베어링 강도를 조사하고 음향방출법을 적용하여 파괴거동을 조사하였다. 복합재는 필라멘트 와인딩 공법을 적용하여 제작되었으며 적층패턴을 달리한 세 종류의 시편을 적용하였다. Type 1은 스티치가 있는 일방향 섬유시트가 적용된 적층패턴을 가지고 있고, Type 2는 스티치가 제거된 일방향 섬유시트가 적용된 적층패턴을 가지고 있으며, Type 3는 프리프레그가 적용된 적층패턴을 가지고 있다. 연구결과에 따르면 Type 1은 Type 2에 비해 베어링 강도가 3.3% 낮게 나타났으며 Type 3가 가장 높은 베어링 강도를 나타내었다. Type 1과 Type 2는 net-tension 모드 파손이, Type 3는 베어링 모드 파손이 나타났으며 Type 3의 음향방출 에너지는 Type 1과 Type 2의 경우에 비해 높게 나타났다. 이로 미루어 보면 Type 3가 구조적으로 가장 안전함을 알 수 있었다.

리기다 소나무 정각재를 사용한 목재옹벽의 직결나사못 접합부 내력 성능 평가 (Strength Performance Evaluation of Threaded Nail Joints of Wooden Retaining Wall Using Pitch Pine (Pinus rigida Miller) Square Timber)

  • 송요진;김건호;이동흡;황원중;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권1호
    • /
    • pp.53-59
    • /
    • 2011
  • 시험 시편은 1개의 횡목과 2개의 종목이 직결나사못 2개로 연결된 접합부(Type-A)와 2개의 횡목과 2개의 종목이 4개의 직결나사못으로 연결된 접합부(Type-B)를 제작하였다. Type-B를 보강하기 위하여 횡목간의 연결부를 끝면거리 5D로 반턱이음하여 2개의 직결나사를 사용한 접합부(Type-C), 끝면거리 10D로 반턱이음한 접합부(Type-C1)와 끝면거리 10D, 직결나사 3개를 사용한 접합부(Type-C2)를 제작하였다. 압축형 전단 내력 시험결과 Type-B의 내력을 기준으로 Type-B를 보완한 Type-C는 약 30% 감소하였고, Type-C에서 끝면거리를 증가시킨 Type-C1은 Type-B와 비슷한 내력을 보였으며, Type-C1에서 직결나사못의 개수를 3개로 증가시킨 Type-C2는 Type-C1과 비교하여 1.28배 내력을 나타냈다. 기존 정각재를 이용한 옹벽의 접합부 중 긴 횡목과 짧은 횡목이 2개의 종목과 연결되는 접합부는 내력이 저하되기 때문에 이를 대체하기 위하여 실험을 실시하였다. 따라서 Type-B를 Type-C2로 대체한다면 옹벽 시공시 직결나사못에 의한 목재의 할렬, 파단과 시공시간이 줄어들고 접합 내력이 증가할 것으로 기대된다.

한국인 중년성인에서 사상체질과 폐기능장애, 대사증후군의 연관성 연구 (Association between Sasang Constitution, Impaired Lung Function and Metabolic Syndrome among Middle-aged Adults in Korea)

  • 박윤성;김제신;이준희;이의주;고병희
    • 사상체질의학회지
    • /
    • 제25권3호
    • /
    • pp.180-194
    • /
    • 2013
  • Objectives Impaired lung function(ILF) and sasang constitution(SC) is associated with metabolic syndrome(MS). However, the relationship between ILF and SC is unclear. So, we assessed the relationship between ILF and MS according to SC, and examined whether SC is an independent risk factor for ILF. Methods This study included 1,148 subjects 40years and older who were performed the health examination at Kyung Hee University Hospital in Korea between December 2011 and February 2013. We defined ILF if FVC or $FEV_1$ value were less than lower limit of normal(LLN), and classified ventilatory patterns as obstructive pattern and restrictive pattern. MS was assessed according to AHA/NHLBI criteria. We used multivariate logistic regression to analyze the association of ILF with MS respective to SC types, and to identify the risk of SC types for ILF. Odds ratio(OR) was calculated by adjusting for age, sex, smoking status, drinking, physical activity, and BMI. Results In whole subjects, ILF was associated with MS [OR (95% CI), 1.69 (1.24-2.31) for FVC, 1.67 (1.20-2.33) for $FEV_1$]. And in Taeeum type(TE type) and Soeum type(SE type), ILF was associated with MS [1.63 (1.10-2.42) for FVC, 1.48 (1.01-2.24) for $FEV_1$ in TE type; 6.93 (1.14-42.00) for FVC in SE type], while in Soyang type(SY type), it wasn't. The restrictive pattern was associated with MS in TE type and SE type, while in SY type, it wasn't. Furthermore, TE type and SY type had more risk for ILF than SE type [1.71 (1.12-2.59) for SY type, 1.95 (1.23-3.08) for TE type in FVC; 2.06 (1.26-3.36) for TE type in $FEV_1$; 1.85 (1.21-2.85) for SY type, 2.17 (1.35-3.49) for TE type in Restrictive pattern]. Conclusions These results show that SC is an independent risk factor for ILF, especially TE type and SY type than SE type, and the prevalence of MS is an independent risk factor for ILF in TE type.

공장배수계에 존재하는 유산간균 Virulent Phage에 관한 연구 (Studies on Lactobacillus Virulent Phage in Plantdrainage)

  • 강국희;백영진;강영찬;김기원
    • 한국미생물·생명공학회지
    • /
    • 제5권1호
    • /
    • pp.13-17
    • /
    • 1977
  • 한국야쿠르트 제조공장의 배수중에 존재하는 L. casei 숙주로 하는 Lactobacillus phage J$_1$계의 분포를 조사한 결과는 다음과 같다. 1. 공장의 배수중의 J$_1$계 phage에는 Type I, II, III, IV가 존재하고 있었으며 분포순위로 보면 Type IV>Type II>Type I>Type III 이었 다. 2. 공장배수중의 phage는 역성비누를 격포하여 완전히 제거되었다. 3. 각종 소독제의 Phage에 대한 살균핵과는 염소수, 역성비누, 크레졸이 가장 강력한 효력을 나타내었고, isopropyl alcohol, ethyl alcohol등은 살균력이 미약하였다.

  • PDF

한국산 체꽃속(Scabiosa L.)의 잎 표피 및 화분의 미세구조 (Leaf Epidermis and Pollen Microstructure of Scabiosa L. in Korea)

  • 최지우;유기억
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2023년도 임시총회 및 춘계학술대회
    • /
    • pp.30-30
    • /
    • 2023
  • 한국산 체꽃속(Scabiosa L.)의 외부형태형질을 바탕으로 구분한 5가지 변이 유형[솔체꽃(S. comosa) Type 1-2, 체꽃(S. tschiliensis f. pinnata) Type 3-4, 구름체꽃(S. tschiliensis f. alpina) Type 5]에 대해 잎 표피와 화분의 미세구조를 관찰하였다. 잎 표피세포의 크기는 향축면은 평균 12.4 × 6.7 ㎛로, Type 1이 가장 작고 Type 3가 가장 컸으며, 배축면은 평균 9.4 × 4.6 ㎛로 모든 유형이 비슷하게 나타났다. 모용은 단세포성 선상 모용이 일부 유형에서, 다세포성 비선상 모용이 모든 유형에서 관찰되었다. 선상 모용은 향축면에서 Type 1과 5에만 있었으며, 두 유형 중 Type 5의 모용이 길이 72.2 ㎛로 더 길고, 단위면적 (0.01 mm2) 당 개수도 5개로 더 많았다. 배축면에서는 Type 1, 3 및 5에 있고, 단위면적 당 개수가 Type 1과 5는 3~6개로 비슷하였으나, Type 3은 1개 이하로 매우 드물게 나타났다. 기공복합체는 부등형으로 양면에 분포하며, 향축면의 공변세포 크기는 평균 4.4 × 2.7 ㎛로 너비는 유사하나 길이는 Type 1과 5가 3.1 ㎛, 3.9 ㎛로 나머지에 비해 작았다. 단위면적 당 기공의 수는 향축면과 배축면이 평균 40.2개, 149.2개이고, 양면 모두 Type 1이 66.3개와 177.2개로 가장 많았다. 화분은 모두 단립으로 삼구형이고, 극축 길이(P)와 적도면 지름(E)의 비율은 0.83~1.12로 모양은 아단구형~약장구형이다. 표면무늬는 과립상 표면에 자상 돌기가 있고, Type 3과 4에서만 유공상이 확인되었다. 이상의 결과에서, 솔체꽃 유형인 Type 1과 2가 잎 표면의 선상 모용 유무 및 기공의 수에 뚜렷한 차이를 보여 Type 1은 솔체꽃과는 다른 새로운 변종 또는 품종일 가능성이 있다고 생각된다. 또한 체꽃 유형인 Type 3과 4의 경우, Type 3의 잎 배축면에 털이 드물게 있으나, 두 유형의 화분 표면무늬가 동일하고, 다른 형질들도 모두 중복되어 연속적인 변이로 보이며, 구름체꽃 유형인 Type 5는 나머지 유형과 뚜렷이 구분되었다.

  • PDF

터널형 하우스에서 환기방법이 참외의 생육 및 품질에 미치는 영향 (Effect of the Ventilation Method on the Growth and Quality of Melon (Cucumis melo L.) in Greenhouse of Tunnel Type)

  • 신용습;연일권;도한우;서동환;배수곤;최성국;최부술
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.187-193
    • /
    • 1996
  • 여름철 고온기 참외재배시 환기방법에 따른 시설내 온도차이가 참외의 생육 및 품질에 미치는 영향을 구명하고자 측면환기공 환기구(Type 1), 측면환기공 환가+천정 환기공 환기구(Type 2) 및 권취식 환기구(Type 3)로 구분하여 시험을 실시한 결과를 요약하면 다음과 같다. 1. 환기방법별 온도의 하강효과는 Type 3이 가장 좋았고 Type 2, Type 1의 순으로 나타났다. 2. 환기방법에 따른 온도분포는 측면환기공만 있는 Type 1과 천정환기통 및 측면환기공이 있는 Type 2의 경우 환기공 및 환기통의 면적이 적어 중력환기 및 풍력환기가 미세하여 온도가 상승하였다. Type 3은 측면환기 면적이 넓어 풍력환기에 의한 공기의 유입, 유출이 쉬워 온도분포가 비교적 균일하였다. 3. 실측치를 이용하여 내외기온차이에 의한 환기량을 추정한 결과, Type 3이 Type 1 및 Type 2보다도 많음을 알 수 있었다. 4. 생육 및 상품성을 조사한 결과, Type 3이 Type 2, Type 1보다도 엽수 및 엽면적이 증가하여 생육이 양호하였고 과중, 과육두께, 기형과율, 상품과율 등 상품성도 우수하였다. 5. 수확시기별 상품수량은 각처리 공히 수확초기 보다는 후기로 갈수록 증가하였다. 특히 Type 3에서 뚜렷한 경향을 보였다.

  • PDF

여성 바지 패턴에 관한 연구(1) -밑위길이 및 앞.뒤 밑너비 연장분 변화량을 중심으로- (A Study on the Slacks Pattern for Women(1) -Depending on the Variation of Crotch Length and Front & Back crotch Width Extension)

  • 김효숙
    • 복식문화연구
    • /
    • 제6권3호
    • /
    • pp.46-55
    • /
    • 1998
  • The purpose of this study was to develop the better fitting and more comfortable slacks pattern for women. 10 types of slacks pattern were made and worn compared with the sensory evaluations method. The main results of this study were as follows 1. Sensory evaluation for appearance; According to the result of means among the 10 slacks patterns, Type 2 method slacks was most satisfactory, and the next was the Type 4 slacks followed by Type 3, Type 5,6, Type 8, Type 1, Type 7, Type 9 Type 10 method slacks. 2. Sensory evaluation for comfort; The result of means showed that the Type 5 method slacks was most comfortable, and the next was the Type 3,8 slacks followed by Type 6,9 Type 7, Type 1,2,3, Type 10 method slacks.

  • PDF

최적 Interval Type-2 퍼지 제어기 설계 및 응용 (Design of Optimized Interval Type-2 Fuzzy Controller and Its Application)

  • 장한종;오성권
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1624-1632
    • /
    • 2009
  • In this study, we introduce the design methodology of an optimized Interval Type-2 fuzzy controller. The fixed MF design of type-1 based FLC leads to the difficulty of rule-based control design for representing the linguistically uncertain expression. In the Type-2 FLC as the expanded type of Type-1 FLC, we can effectively improve the control characteristic by using the footprint of uncertainty(FOU) of membership function. Type-2 FLC has a robust characteristic in the unknown system with unspecific noise when compared with Type-1 FLC. Through computer simulation as well as practical experiment, we compare their performance by applying both the optimized Type-1 and Type-2 fuzzy cascade controllers to ball and beam system. To evaluate each controller performance, we consider controller characteristic parameters such as maximum overshoot, delay time, rise time, settling time and steady-state error.