• 제목/요약/키워드: Two-sample T-test

검색결과 581건 처리시간 0.028초

Two tests using more assumptions but lower power

  • Sang Kyu Lee;Hyoung-Moon Kim
    • Communications for Statistical Applications and Methods
    • /
    • 제30권1호
    • /
    • pp.109-117
    • /
    • 2023
  • Intuitively, a test with more assumptions has greater power than a test with fewer assumptions. This kind of examples are abundant in the nonparametric tests vs corresponding parametric ones. In general, the nonparametric tests are less efficient in terms of asymptotic relative efficiency (ARE) compared to corresponding parametric tests (Daniel, 1990). However, this is not always true. To test equal means under independent normal samples, the usual test involves using the t-distribution with the pooled estimator of the common variance. Adding the assumption of equal sample size, we may derive another test. In this case, two tests using more assumptions were performed for univariate (multivariate) cases. For these examples, it was found that the power function of a test with more assumptions is less than or equal to that of a test with fewer assumptions. This finding can be used as an expository example in master's mathematical statistics courses.

Study of dynamic mechanical behavior of aluminum 7075-T6 with respect to diameters and L/D ratios using Split Hopkinson Pressure Bar (SHPB)

  • Kim, Eunhye;Changani, Hossein
    • Structural Engineering and Mechanics
    • /
    • 제55권4호
    • /
    • pp.857-869
    • /
    • 2015
  • The aluminum 7075-T6 is known as an alloy widely used in aircraft structural applications, which does not exhibit strain rate sensitivity during dynamic compressive tests. Despite mechanical importance of the material, there is not enough attention to determine appropriate sample dimensions such as a sample diameter relative to the device bar diameter and sample length to diameter (L/D) ratio for dynamic tests and how these two parameters can change mechanical behaviors of the sample under dynamic loading condition. In this study, various samples which have different diameters of 31.8, 25.4, 15.9, and 9.5 mm and sample L/D ratios of 2.0, 1.5, 1.0, 0.5, and 0.25 were tested using Split Hopkinson Pressure Bar (SHPB), as this testing device is proper to characterize mechanical behaviors of solid materials at high strain rates. The mechanical behavior of this alloy was examined under ${\sim}200-5,500s^{-1}$ dynamic strain rate. Aluminum samples of 2.0, 1.5 and 1.0 of L/D ratios were well fitted into the stress-strain curve, Madison and Green's diagram, regardless of the sample diameters. Also, the 0.5 and 0.25 L/D ratio samples having the diameter of 31.8 and 25.4 mm followed the stress-strain curve. As results, larger samples (31.8 and 25.4 mm) in diameters followed the stress-strain curve regardless of the L/D ratios, whereas the 0.5 and 0.25 L/D ratios of small diameter sample (15.9 and 9.5 mm) did not follow the stress-strain diagram but significantly deviate from the diagram. Our results indicate that the L/D ratio is important determinant in stress-strain responses under the SHPB test when the sample diameter is small relative to the test bar diameter (31.8 mm), but when sample diameter is close to the bar diameter, L/D ratio does not significantly affect the stress-strain responses. This suggests that the areal mismatch (non-contact area of the testing bar) between the sample and the bar can misrepresent mechanical behaviors of the aluminum 7075-T6 at the dynamic loading condition.

용혈검체가 핵의학 검체검사 결과에 미치는 영향 (The Effect of Hemolysis sample on the Result of Nuclear Medicine Blood test)

  • 김진태;이종필;이수빈;김동민
    • 핵의학기술
    • /
    • 제25권1호
    • /
    • pp.41-43
    • /
    • 2021
  • 용혈 검체는 혈액검사 결과에 영향을 미치는 요인 중 하나이다. 핵의학 분야 또한 용혈 검체를 부적합검체를 분류하고 채혈실에 재 채혈을 요구하기도 한다. 이는 신속한 검사를 진행해야 하는 검사실 입장에선 장애 요소이기도 하다. 그러나 진단검사의학에서는 용혈이 각 검사 종목에 미치는 영향이 많이 알려진 반면, 핵의학에서는 용혈이 얼마나 검사 결과에 영향을 미치는지 실험을 통해 알려진 바가 없어 알아보고자 한다. 먼저, 19명의 환자에서 한 명당 각2개의 검체를 획득하고, 하나는 정상적인 혈청을 얻고, 다른 하나는 인위적으로 용혈 혈청을 획득했다. 그리고 각 종목별(AFP, CEA, PSA, CA-125, CA19-9, Thyroglobulin, Prolactin, E2, Insulin, T3, T4, TSH, FT4, TG-Ab, Anti-TPO, TBII, LH, FSH, Testosterone, PTH, DHEA-s, Cortisol, C-peptide)로 검사를 실시 한 후, 용혈검체와 정상 검체간의 결과값을 t-test를 통하여 통계적으로 유의성을 확인해 보았다. 실험 결과 키트 내 매뉴얼에 용혈검체를 사용하지 않도록 한 검사 종목 뿐만 아니라 대부분의 종목에서 용혈이 핵의학 검사결과에 영향을 미치지 않음을 알 수 있었다. 그러나, 인슐린과 C-peptide의 경우에는 용혈검체가 정상검체에 비해 통계적으로 유의하게 나타났다(P<0.05). 검체의 수가 적어 모든 검사 결과에 일반화 시킬 수는 없으나, 모든 용혈 검체를 부적합 검체로 간주하여 재채혈을 요구할 필요가 없음 또한 확인되었다. 그러므로 복잡한 핵의학 검사실의 접수 업무 개선에 도움이 될 것이라 생각된다.

유아의 종이접기 활동이 기하 도형의 이해에 미치는 영향 (The Effects of Paper Folding Activities on the Understanding of Geometric Figures by Kindergarten Children)

  • 김혜숙;홍혜경
    • 아동학회지
    • /
    • 제20권3호
    • /
    • pp.325-337
    • /
    • 1999
  • In this intervention study, an experimental group of kindergarten children participated in paper folding activities 2 times per week for 10 weeks while the control group did ordinary art activities. Subjects were 43 five-year-old children enrolled in N and D public kindergartens in Hwa-soon Chonnam province. Data were analyzed with a two-sample t-test. The ability to draw and to manipulate geometric figures increased significantly in the experimental group but there was no difference between the two groups in the discrimination of geometric figures.

  • PDF

제3차 어린이집 표준보육과정의 영역별 내용에 대한 영아교사의 인식과 적용 실제 (Toddler Teachers' Perception and Application of the Contents of the 3rd Standard Educare Curriculum)

  • 김지영;김동례
    • 한국콘텐츠학회논문지
    • /
    • 제16권5호
    • /
    • pp.318-326
    • /
    • 2016
  • 본 연구의 목적은 영아교사의 변인에 따라 표준보육과정의 영역별 내용에 대한 인식과 적용 실제를 조사하고, 영아교사의 표준보육과정 영역의 내용 이해도와 적용 실제 간에 차이를 분석하는 것이다. 연구대상은 전라남도의 어린이집에 근무하는 만 2세를 담당하는 영아교사 205명이다. 연구도구는 제3차 어린이집 표준 보육과정의 영역별 내용을 참고하여 연구목적에 적절하게 제작된 질문지를 사용하였다. 수집된 자료는 SPSS 18.0 프로그램을 이용하여 빈도분석, 기술통계, 대응표본 t검증, 독립표본 t검증, F검증, Duncan 사후 분석을 실시하였다. 연구결과를 제시하면 다음과 같다. 첫째, 영아교사의 표준보육과정의 영역별 내용에 대한 이해 수준은 높으며, 특히 영아교사의 학력이 높을수록 이해도가 높은 것으로 나타났다. 둘째, 영아교사의 표준보육과정의 영역별 내용에 대한 적용 수준은 비교적 높은 것으로 나타났다. 셋째, 영아교사의 표준 보육과정 영역별 내용에 대한 이해도와 적용 실제 간에는 통계적으로 유의미한 차이가 있었다.

세라믹 코팅 Al 부스바의 전기적 특성 연구 (Study on Electrical Properties of Ceramic Coated Al Bus Bar)

  • 백승명;곽민환;곽동순
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1647-1650
    • /
    • 2017
  • Bus bars are used in place of cables because they can carry more electrical energy with the same volume of conductors. This paper deals with the electrical properties of ceramic coating material for busbars. A ceramic coated samples were prepared for the electrical properties test. There are two types of samples. One is a sample without degradation, and the other is a sample degraded for 30 days. Four electrical properties tests were carried out in accordance with domestic standards. Four electrical characteristics tests are AC dielectric breakdown, V-t, lighting impulse dielectric breakdown, and discharge arc. Both samples showed excellent electrical properties, and the ceramic coating material is very good insulating materials for bus bar.

향기요법이 고등학생의 스트레스와 스트레스 반응에 미치는 효과 (The Effects of Aromatherapy on Stress and Stress Responses in Adolescents)

  • 서지영
    • 대한간호학회지
    • /
    • 제39권3호
    • /
    • pp.357-365
    • /
    • 2009
  • Purpose: This study was done to examine the effects of aromatherapy on stress and stress responses in adolescents. Methods: A two-group cross-over design was used for this study. The experimental treatment was aroma essential oil inhalation and the placebo treatment was carrier oil inhalation using a necklace. The sample included 36 female high school students. Fisher's exact test, t-test, and paired t-test using SPSS/WIN program were used to analyze the data. Results: Stress levels were significantly lower when the students received the aroma treatment compared to when they received the placebo treatment. The stress responses except salivary IgA levels were significantly lower when the students received the aroma treatment. Conclusion: Aroma inhalation could be a very effective stress management method for high school students. Therefore, it is recommended that this program be used in clinical practice as an effective nursing intervention for high school students.

Cryogenic Thermal Cycling Test on IGRINS cross-disperser VPH Grating

  • 정현주;임주희;이성호;;박수종;육인수
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.156-156
    • /
    • 2011
  • VPH (Volume Phase Hologram) grating is one of the transmission gratings and is known as its remarkable efficiency (>90%). It has two different densities of gelatins causing interference patterns. The VPH grating is favored in many astronomical instruments these days and also IGRINS, which is up coming near infrared high-resolution spectroscope expected to see the first light next year, uses the VPH grating as its cross-disperser. The infrared astronomical instruments operate at cryogenic temperature (~100K) in order to cut down thermal noise and the optical components of IGIRNS will be operated at 130K. The VPH grating is sandwiched in between fused silica or glass and glued together using optical adhesive. IGRINS is expected to go through 50 times of thermal cycling in 10 years including the performance test and this research is to check whether the physical characteristic such as the adhesion or dichromatic gelatin does not break and change from the several cryogenic thermal cycling. The two identical test gratings provided from Kaiser Optical System, Inc. are used in this test. One VPH grating is cooled down to 100K for 2 hours with maximum dT/dt = 5 and warmed up to the room temperature and another grating is kept stored in the room temperature and used as a control sample. In order to check the change, we inspected the grating with eyes and checked its efficiency and transmission at the room temperature every 10 cycling. From the 40 times of cryogenic temperature cool down cycling, the VPH grating showed no signs of change within the error compared to the control sample. We concluded the VPH grating is durable through several cryogenic thermal cycling.

  • PDF

여성 간호사의 근무형태 선호도에 따른 조직몰입 및 이직의도 비교연구 (A Comparative Study on Organizational Commitment and Turnover Intention according to the Type of Shift Work Preferred by Female Nurses)

  • 이현주
    • 산업융합연구
    • /
    • 제19권5호
    • /
    • pp.119-128
    • /
    • 2021
  • 본 연구는 여성 간호사가 선호하는 근무형태에 따른 조직몰입도와 이직의도를 비교하여 여성 간호사의 근무 환경을 개선하고자 수행되었다. 본 연구는 서술적 조사연구로서 7개 의료기관에서 3교대 근무중인 여성 간호사 465명에게 온라인 설문조사를 통해 자료수집을 하였다. 수집된 자료는 SPSS WIN 24.0를 이용하여 χ2 test, two sample independent t-test, pearson correlation, MANCOVA로 분석한 결과 고정근무 선호집단의 연령이 많을수록 조직몰입도가 높았으며, 이직경험이 있는 경우 이직의도가 높았다. 그리고 고정근무 선호집단이 교대근무 선호집단 보다 조직몰입도가 낮았으며 이직의도가 높았다. 고정근무를 희망하는 여성 간호사들의 조직몰입도를 높이고, 이직을 줄이기 위해서는 다양한 근무형태를 개발하여 여성 간호사의 근무환경을 개선하기 위한 노력이 필요하다.

P300 숨긴정보검사에서 t 검증이 부트스트랩 방법보다 덜 민감한가? (Is the t-test insensitive than the bootstrap method in the P300-based concealed information test?)

  • 엄진섭;손진훈;박미숙
    • 한국심리학회지:법
    • /
    • 제11권1호
    • /
    • pp.21-36
    • /
    • 2020
  • P300 숨긴정보검사에서는 조사대상자가 거짓을 말하고 있는지 판단하기 위하여 관련자극의 P300 진폭이 무관련자극의 P300 진폭보다 통계적으로 유의하게 더 큰지를 평가한다. 구체적인 통계적 방법으로 독립표본 t 검증 또는 부트스트랩 방법을 사용할 수 있다. Rosenfeld와 Soskins, Bosh, Ryan(2004)은 "개인 내에서 관련자극과 무관련자극의 P300 평균을 비교하는데 사용하기에는 t 검증이 너무 둔감하다."면서 부트스트랩 방법을 사용하였다. 본 연구의 목적은 P300 숨긴정보검사에서 t 검증의 검증력이 부트스트랩 방법보다 더 낮은지 평가하는 것이다. 이를 위하여 39명의 실험참가자로부터 측정한 뇌파자료를 이용하여 Monte Carlo 연구를 수행하였다. 연구결과, t 검증과 백분위를 이용한 부트스트랩 방법의 1 종 오류율은 서로 비슷하였으며, 백분위를 이용한 부트스트랩 방법의 검증력이 t 검증의 검증력보다 약간 더 높았다. 두 검증 방법의 1 종 오류율은 모두 유의수준보다 낮은 값을 보였으며, 검증력은 이론적인 t 검증의 검증력보다 약간 낮은 값을 보였다. 반면에 표준오차를 이용한 부트스트랩 방법의 1 종 오류율과 검증력은 이론적인 t 검증의 1 종 오류율 및 검증력과 비슷한 값을 보였으며, t 검증의 검증력보다 실험조건에 따라 .012 ~ .081 더 높았다.

  • PDF