• 제목/요약/키워드: Two-ray

Search Result 2,951, Processing Time 0.032 seconds

Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system (X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

Investigating X-ray cavities and the environmental effects

  • Shin, Jaejin;Woo, Jong-Hak;Mulchaey, John S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.34.2-34.2
    • /
    • 2016
  • X-ray cavities are typically detected as surface brightness depression in X-ray diffuse emission from hot gas in high resolution X-ray images (i.e., Chandra and XMM-Newton). Showing the coincidence of location with radio jets, X-ray cavities imply that the radio jets interact with interstellar/intergalactic medium. It is important to understand them since they can be a clue of understanding AGN feedback to their host galaxies. To understand the physics of the AGN feedback, X-ray cavity has been actively studied while there are only a few statistical studies on X-ray cavity based on small or incomplete samples. Hence, a systematic study with a large sample is needed. With the condition of sufficient X-ray photons to detect surface brightness depression, we constructed a large sample of 133 galaxy clusters, galaxy groups, and individual galaxies to investigate X-ray cavities. We detected 201 cavities from 94 objects using two detection methods (i.e., beta-modeling and unsharp masking method), and confirmed the cavity size-distance relation over a large dynamical range. The size-distance relation does not vary for different environments (i.e., galaxy cluster, groups, and individual galaxies), suggesting that there is little environmental effect on the formation of X-ray cavity.

  • PDF

Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging (소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발)

  • Park, Jeong-Jin;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Improved X-ray Center Beam Alignment Evaluation Method (개선된 X선 중심선속정렬평가 측정법)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.827-832
    • /
    • 2020
  • X-ray equipment, which is frequently used in radiology and treatment, is the most common and most used equipment in clinical practice. Equipment must provide accurate information to patients through continuous quality control. In case of manual quality control measurement, reproducibility may be poor and there may be a problem with reliability of evaluation results. In this study, an automated program was developed and attempted to measure how much the central ray between the focus of the X-ray tube and the variable aperture of the diagnostic X-ray generator used in clinical practice coincides. As a result of the experiment, it succeeded in calculating the coordinates of the two center points, and the distance between the two points was calculated in pixels and applied to the judgment and the automatic judgment value for whether the center line coincidence is within the normal angle or the abnormal angle is presented. The results of this study are considered to be very helpful in the quality control of the X-ray apparatus.

Three Dimensional Volume Reconstruction of an Object from X-ray Iamges using Uniform and Simultaneous ART (USART 방법에 의한 X선 영상으로부터의 삼차원 물체의 형상 복원)

  • Roh, Young-Jun;Cho, Hyung-Suck;Kim, Hyeong-Cheol;Kim, Jong-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.21-27
    • /
    • 2002
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. A number of visual or optical technologies have been successfully applied to measure three-dimensional surfaces. However, those conventional visual or optical methods have inherent shortcomings such as occlusion and variant surface reflection. X-ray vision system can be a good solution to these conventional problems, since we can extract the volume information including both the surface geometry and the inner structure of any objects. In the x-ray system, the surface condition of an object, whether it is lambertian or specular, does not affect the inherent characteristics of its x-ray images. In this paper, we propose a three-dimensional x-ray imaging method to reconstruct a three dimensional structure of an object out of two dimensional x-ray image sets. To achieve this by the proposed method, two or more x-ray images projected from different views are needed. Once these images are acquired, the simultaneous algebraic reconstruction technique(SART) is usually utilized. Since the existing SART algorithms have several shortcomings such as low performance in convergence and different convergence within the reconstruction volume of interest, an advanced SART algorithm named as USART(uniform SART) is proposed to avoid such shortcomings and improve the reconstruction performance. Because, each voxel within the volume is equally weighted to update instantaneous value of its internal density, it can achieve uniform convergence property of the reconstructed volume. The algorithm is simulated on various shapes of objects such as a pyramid, a hemisphere and a BGA model. Based on simulation results the performance of the proposed method is compared with that of the conventional SART method.

A Study on the 3D Representation of 2D Projection Data using Epipolar Geometry (Epipolar 기하학을 이용한 2차원 투영 데이터의 3차원 표현에 관한 연구)

  • Yu, Seon-Guk;Wang, Ge;Kim, Nam-Hyeon;Kim,Yong-Uk;Kim, Hui-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.212-219
    • /
    • 2002
  • In this paper, the epipolar geometry, genera17y used as a pin-hole camera model, is newly adapted to our proposed method that enables the affine reconstruction of the 3D object from two projected views. The proposed method models the projective projection of inherent X-ray imaging system, obviates the need to attach artifirially constructed material on the body, and requires none of the prior-knowledge regarding to intrinsic and extrinsic parameters of two X-ray imaging systems. The optimum numerical solution is obtained by applying the least mean square estimator to corresponding points on two projected X-ray planes. The performance of this proposed method is Quantitatively analyzed using computer synthesized model of Cochlear implantation electrodes. In simulated experiments, the propnsed method is insensitive to the added random noise, the scaling factor change, the center point change, and rotational angular change between two projection planes, as well as enables the stable 3D reconstruction in least square sense even in worst testing cases.

Analysis of X-ray image qualities-accuracy of shape and clearness of image-using X-ray digital tomosynthesis

  • Roh, Young Jun;Kang, Sung Taek;Kim, Hyung Cheol;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.572-576
    • /
    • 1997
  • X-ray laminography and DT(digital tomosynthesis) that can form a cross-sectional image of 3-D objects promise to be good solutions for inspecting interior defects of industrial products. The major factors of the digital tomosynthesis that influence on the quality of x-ray cross-sectional images are also discussed. The quality of images acquired from the DT system varies according to image synthesizing methods, the number of images used in image synthesizing, and X-ray projection angles. In this paper, a new image synthesizing method named 'log-root method' is proposed to get clear and accurate cross-sectional images, which can reduce both artifact and blurring generated by materials out of focal plane. To evaluate the quality of cross-sectional images, two evaluating criteria: (1) shape accuracy and (2) clearness in the cross-sectional image are defined. Based on this criteria, a series of simulations were performed, and the results show the superiority of the new synthesizing method over the existing ones such as averaging and minimum method.

  • PDF

Dimensions of Structural Elements in Fusiform Ray of Sitka Spruce (Picea sitchensis (Bong.) Carr.) Affecting Radial Permeability

  • Usta, Ilker
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.5 s.133
    • /
    • pp.1-6
    • /
    • 2005
  • The anatomical structure of fusiform ray was examined by scanning electron microscopy (and microscopic images were analysed by image analyser) to explain the differences in radial fluid uptake between the extremes in the radial treatment data, i.e. between the selected trees of QCI (Queen Charlotte Islands in Rhondda, South Wales) and SO (South Oregon in Dalby, North-East England) planted in the UK. The ray structure of these two seed origins was examined microscopically and different patterns of ray composition were observed. The most important anatomical features influencing radial permeability were the nature of fusiform ray, and the condition of the resin canals, epithelial cells and intercellular spaces in particular.

Functional Disturbances Through the Retinal Pigment Reaction of the Automatic Nervous System of Tadpoles Developed under Various Visible Rays (망막반응으로 본 각종파장가시광선조사하에서 발육한 과두(올챙이)의 식물신경계기능변조에 관하여)

  • 주인호
    • The Korean Journal of Zoology
    • /
    • v.1 no.2
    • /
    • pp.17-24
    • /
    • 1958
  • Since Kesser first described in 1934 the functional change of the autonomic nervous system caused by certain visible rays many researchers have unanimously approved that animals flashed with a red visible ray develop parasympathicotony while those flashed with a blue visible ray develop sympathicotony. On the other hand through studies made by our colleagues it is now well known that the inner-movement of the retinal pigments of frogs is stimulated in sympathicotony and is in reverse inhibited in parasimpathicotony. It is almost evident that the mechanism by which the inner-movement of the retinal pigments is due to sympathicotony derived from the excessive secretion of adrenalin. In addition , through may recent experiments on the pharmacological action of various medicines on the retinal pigments reaction of tadpoles , ranging from the excessive secretion of adrenalin. In addition , through my recent experiments on the pharmacologtical action of various medicines on the retinal pigments reaction of tadploes, raging from every developmental stage , Ifound that the movement of the retinal pigments by adrenalin is predominant in the earlier developmental stages of taopoles around 11 mm of body length, whereas other medicines fail to give any responce to the retinal pigments in such an earlier stage. When tadpoles grown to body length of 15-16m the retinal pigments move to the complete light position while kept in adrenalin solution. Based on these facts it might be well to consider that if tadpoles were grown under the visible rays for a given period, they might show a functional change of the autonomic nervous system and thereby cause of certain change in the physciological phases of the retinal reaction. Experiments were undertaken to find this matter and also to discover the simultaneous effects of the visible radiations on the developmental process of tadpoles. The results summarized as follows ; 1. The longest wave of visible rav has an effective reaction on the growth of body length of taopoles, while the shortest wave of visible ray causes the same for the metamorphoric differentiation of tadpoles. 2. When keeping two groups of tadpoles the first group of 15 mm body length grown for the period of one week and the latter group of 20 mm body length grown for two weeks under the various visible rays. swimming in adrenalin solution, the inner-movement of the retinal pigment occurs in both groups. The movement of pigments of the first group is accelerated in a sequence of blue ray \ulcorner green ray > brown ray> red ray, and that of the latter group is also accelerated in a sequence of blue ray>green ray > brown ray and red ray. 3. When keeping tow groups of tadpoles, the first group of 20 mm body length grown for the period of two weeks, the latter group of 25 m body length grown for three wheeks, under the various visible rays in sunlight, the inner-movement of the retinal pigments occurs in both groups. The movement of pigments of the first group is accelerated in a sequence of blue ray> green ray>brown ray and red ray, and that of the latter group is also accelerated in a sequence of blue ray > brow ray>red ray. 4. In order words, there facts manifest that tadpoles grown under the various visible rays reveal functional disturbances of the autonomic nervous system, at the time of 15 mm body length by adrenalin solution, which is a unique indicator illustrating the status of sympathicotony, and at the time of 20 mm body length by sunlight. This means that the longest visible ray cause sympathicotony, while the shortest visible ray causes parasympathicotony.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF