• Title/Summary/Keyword: Two-frequency difference method

Search Result 435, Processing Time 0.032 seconds

Effective Separation Method for Single-Channel Time-Frequency Overlapped Signals Based on Improved Empirical Wavelet Transform

  • Liu, Zhipeng;Li, Lichun;Li, Huiqi;Liu, Chang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2434-2453
    • /
    • 2019
  • To improve the separation performance of time-frequency overlapped radar and communication signals from a single channel, this paper proposes an effective separation method based on an improved empirical wavelet transform (EWT) that introduces a fast boundary detection mechanism. The fast boundary detection mechanism can be regarded as a process of searching, difference optimization, and continuity detection of the important local minima in the Fourier spectrum that enables determination of the sub-band boundary and thus allows multiple signal components to be distinguished. An orthogonal empirical wavelet filter bank that was designed for signal adaptive reconstruction is then used to separate the input time-frequency overlapped signals. The experimental results show that if two source components are completely overlapped within the time domain and the spectrum overlap ratio is less than 60%, the average separation performance is improved by approximately 32.3% when compared with the classic EWT; the proposed method also improves the suitability for multiple frequency shift keying (MFSK) and reduces the algorithm complexity.

Performance Analysis of Short Baseline Integer PPP (IPPP) for Time Comparison

  • Lee, Young Kyu;Yang, Sung-hoon;Lee, Ho Seong;Lee, Jong Koo;Hwang, Sang-wook;Rhee, Joon Hyo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.4
    • /
    • pp.379-385
    • /
    • 2021
  • In order to synchronize a remote system time to the reference time like Coordinated Universal Time (UTC), it is required to compare the time difference between the two clocks. GNSS Precise Point Positioning (PPP) is one of the most general geodetic positioning methods and can be used for time and frequency transfer applications which require more precise time comparison performance than GNSS code. However, the PPP technique has a main drawback of day-boundary discontinuity which comes from the PPP model that the code measurements are applied to resolve the floating carrier-phase ambiguities. The Integer PPP (IPPP) technique is one of the methods which has been studied to compensate the day-boundary discontinuities exited in the conventional PPP. In this paper, we investigate the time and frequency capabilities of PPP and IPPP by using the measurement data obtained from two time transfer receivers which are closely located and using common reference 1 Pulse Per Second (PPS) and RF signals. From the experiment, it is investigated that the IPPP method can effectively compensate the day-boundary discontinuities without producing frequency offset. However, the PPP method can generating frequency offset which can severely degrade the time comparison performance with long-term period data.

Changes in binaural beat strength to the difference of right and left hearing ability (좌우 청력 차이에 따른 바이노럴 비트 세기의 변화)

  • Kim, Seong Chan;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.1
    • /
    • pp.57-63
    • /
    • 2020
  • The binaural beat is a subjective beating phenomenon due to the frequency difference of sounds heard in both ears, sensed by the human brain. The beating magnitude physically depends on the amplitudes of the two signals with slight different frequencies. Therefore, the binaural beat strength is expected to be affected by the difference in left and right hearing ability. In this study, 34 healthy subjects without hearing loss were chosen. They hear a pure tone sound (450 Hz) at 10 different Sound Pressure Levels (SPLs) (from 50 dB to 27.4 dB) through the one side of ears, while they hear the reference sound (440 Hz, 50 dB) through the other side of ears. Their subjective assessment using a semantic differential method reveals that the binaural beat strength decreases as SPL differences between the two sides of ears increases, if the difference is greater than 2.2 dB. The result suggests that the hearing loss difference between the two sides of ears should be less than 2.2 dB to maximize binaural beating effects.

Numerical Simulation of Aerodynamic Sound by the Finite Difference Lattice Boltzmann Method (차분격자볼츠만법에 의한 유동소음의 수치계산)

  • 강호근;김은라
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.10-17
    • /
    • 2004
  • In this research, a numerical simulation for the acoustic sounds around a two-dimensional circular cylinder in a uniform flaw was developed, using the finite difference lattice Boltzmann model. We examine the boundary condition, which is determined by the distribution function concerning density, velocity, and internal energy at the boundary node. Pressure variation, due to the emission of the acoustic waves, is very small, but we can detect this periodic variation in the region far from the cylinder. Daple-like emission of acoustic waves is seen, and these waves travel with the speed of sound, and are synchronized with the frequency of the lift on the cylinder, due to the Karman vortex street. It is also apparent that the size of the sound pressure is proportional to the central distance to the circular cylinder. The lattice BGK model for compressible fluids is shown to be a powerful tool for the simulation of gas flaws.

Effects of Aroma Inhalation on Fatigue and Sleep Quality of Postpartum Mothers

  • Lee, Sung-Hee
    • Women's Health Nursing
    • /
    • v.10 no.3
    • /
    • pp.235-243
    • /
    • 2004
  • Purpose: The purpose of this study was to measure the effects of aroma inhalation on fatigue and quality of sleep of postpartum mothers. Method: The study design was a non-equivalent control group pre-post design. 51 Postpartum mothers were assigned either to a control group or to an experimental group that was exposed to aromas through inhalation for 6 days. Subjects in the experimental group were instructed to wear a necklace filled with Lavender and Eucalyptus oil from 2:00 PM to 8:00 PM every day. Fatigue was measured using the Rhoten Fatigue Scale. Sleep duration, night arousal frequency and sleep satisfaction were used to assess the quality of sleep. Result: There was a significant difference in the score of fatigue following the treatment between the experimental and control groups (t=-2.79 p=.00). However, there was no significant difference in sleep duration, frequency of night arousal and sleep satisfaction following aroma inhalation between two groups. Conclusion: This intervention appears to be effective in reducing the fatigue in postpartum mothers.

  • PDF

Discrete Optimization for Vibration Design of Composite Plates by Using Lamination Parameters

  • Honda, Shinya;Narita, Yoshihiro;Sasaki, Katsuhiko
    • Advanced Composite Materials
    • /
    • v.18 no.4
    • /
    • pp.297-314
    • /
    • 2009
  • A design method is proposed to optimize the stacking sequence of laminated composite plates for desired vibration characteristics. The objective functions are the natural frequencies of the laminated plates, and three types of optimization problems are studied where the fundamental frequency and the difference of two adjacent frequencies are maximized, and the difference between the target and actual frequencies is minimized. The design variables are a set of discrete values of fiber orientation angles with prescribed increment in the layers of the plates. The four lamination parameters are used to describe the bending property of a symmetrically laminated plate, and are optimized by a gradient method in the first stage. A new technique is introduced in the second stage to convert from the optimum four lamination parameters into the stacking sequence that is composed of the optimum fiber orientation angles of all the layers. Plates are divided into sub-domains composed of the small number of layers and designed sequentially from outer domains. For each domain, the optimum angles are determined by minimizing the errors between the optimum lamination parameters obtained in the first step and the parameters for all possible discrete stacking sequence designs. It is shown in numerical examples that this design method can provide with accurate optimum solutions for the stacking sequence of vibrating composite plates with various boundary conditions.

Direct Numerical Simulation of the Flow Past an Oscillating Circular Cylinder (진동하는 원주주위 유동의 직접수치해석)

  • Kang S. J.;Tanahashi M.;Miyauchi T.;Lee Y. H.
    • Journal of computational fluids engineering
    • /
    • v.6 no.4
    • /
    • pp.26-34
    • /
    • 2001
  • The flow past a circular cylinder forced to vibrate transversely is numerically simulated by solving the two-dimensional Navier-Stokes equations modified by the vibration velocity of a circular cylinder at a Reynolds number of 164. The higher-order finite difference scheme is employed for the spatial discretization along with the second order Adams-Bashforth and the first order backward-Euler time integration. The calculated cylinder vibration frequency is between 0.60 and 1.30 times of the natural vortex-shedding frequency. The calculated oscillation amplitude extends to 25% of the cylinder diameter and in the case of the lock-in region it is 60%. It is made clear that the cylinder oscillation has influence on the wake pattern, the time histories of the drag and lift forces, power spectral density and phase diagrams, etc. It is found that these results include both the periodic (lock-in) and the quasi-periodic (non-lock-in) state. The vortex shedding frequency equals the driving frequency in the lock-in region but is independent in the non-lock-in region. The mean drag and the maximum lift coefficient increase with the increase of the forcing amplitude in the lock-in state. The lock-in boundaries are also established from the present direct numerical simulation.

  • PDF

Direct Numerical Simulation of the Flow Past an Oscillating Circular Cylinder (진동하는 원주주위 유동의 직접수치해석)

  • KANG Shin-Jeong;TANAHASHI Mamoru;MIYAUCHI Toshio;NAM Cheong-Do;LEE Young-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.181-188
    • /
    • 2001
  • The flow past a circular cylinder forced to vibrate transversely is numerically simulated by solving the two-dimensional Wavier-Stokes equations modified by the vibration velocity of a circular cylinder at a Reynolds number of 164. The higher-order finite difference scheme is employed for the spatial discretization along with the second order Adams-Bashforth and the first order backward-Euler time integration. The calculated cylinder vibration frequency is between 0.60 and 1.30 times of the natural vortex-shedding frequency. The calculated oscillation amplitude extends to $25\%$ of the cylinder diameter and in the case of the lock-in region it is $60\%$. It is made clear that the cylinder oscillation has influence on the wake pattern, the time histories of the drag and lift forces, power spectral density and phase diagrams, etc. It is found that these results include both the periodic (lock-in) and the quasi-periodic (non-lock-in) state. The vortex shedding frequency equals the driving frequency in the lock-in region but is independent in the non-lock-in region. The mean drag and the maximum lift coefficient increase with the increase of the forcing amplitude in the lock-in state. The lock-in boundaries are also established from the present direct numerical simulation.

  • PDF

Effects of Different Infusion Frequency of Liquid Nitrogen on Human Embryo Development and Pregnancy Rates after Freezing and Thawing (인간 배아 동결 해빙시 액체질소의 분사속도가 배아 발달 및 임신에 미치는 영향)

  • Kim, Young-Ah;Seo, Seong-Seog;Kim, Mi-Ran;Hwang, Kyung-Joo;Park, Dong-Wook;Jo, Mi-Yeong;Ryu, Hee-Suk
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.28 no.4
    • /
    • pp.287-293
    • /
    • 2001
  • Objective : To investigate the efficacy of high infusion frequency of liquid nitrogen on pregnancy in human embryo after freezing and thawing. Materials and Methods: 150 infertile patients underwent 162 consecutive thawing-ET cycles. In the high infusion frequency group (Group A), 47 patients (50 cycles) underwent cryopreservation with high infusion frequency of liquid nitrogen. In the low infusion frequency group (Group B), 103 patients (112 cycles) underwent cryopreservation with low infusion frequency of liquid nitrogen. We analyzed the clinical characteristics, fertilization rates, development of embryo, good quality embryo ratio, implantation rates, and pregnancy rates between these two groups. Results: There was no difference between the groups with regard to clinical characteristics (mean age, infertility duration, infertility factors, hormone profile), mean number of oocyte retrieval, fertilization rates, and mean embryo number of transfers. The survival rates in group A was 64.9% (228 of 350 embryos), and among the 228 embryos 190 embryos (83.3%) which progressed to the two- to eight-cell stage. After thawing, the embryo numbers were 65 (34.2%), 29 (15.3%), 35 (18.4%), and 37 (19.5%) of grades 1, 2, 3, and above 4, respectively. The survival rates in group B was 63.8% (482 of 755 embryos), and among the 482 embryos 465 embryos (96.5%) which progressed to the two- to eight-cell stage. After thawing, the embryo numbers were 106 (22.8%), 94 (20.2%), 89 (19.1%), and 112 (24.1%) of grades 1, 2, 3, and above 4, respectively. There was no difference in embryo quality change after the freezing-thawing procedure between the groups. Implantation rates (31.1% vs. 34.3%) were not significant. However hCG positive rates in group A (40%) were higher than group B, but not statistically significant. Clinical pregnancy rate (26% vs. 25.9%), on going pregnancy rates (>20 weeks) were not significant (26% vs. 25%). Conclusion: We compared embryo quality change, survival rates, and pregnancy rates between high infusion frequency group and low infusion frequency group and the results were similar between the two groups. Therefore, high infusion frequency of liquid nitrogen for cryopreservation is a worthy method to preserve in human embryos.

  • PDF

Effects of a Workbook Program on the Perceived Stress Level, Maternal Role Confidence and Breast Feeding Practice of Mothers of Premature Infants (워크북 프로그램이 미숙아어머니의 스트레스, 모성역할 자신감, 모유수유 실천에 미치는 효과)

  • Jang Yung-sook
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.2
    • /
    • pp.419-427
    • /
    • 2005
  • Purpose: The purpose of this study was to identify the effects of a workbook program on percieved stress levels, maternal role confidence and breastfeeding practices of mothers of premature infants. Method: This study employed a quasi-experimental non-equivalent pre-and-post test to compare the two groups. Data was collected from 32 subjects from March 10. to September 5, 2003 at an NICU located in S. city. In the sample, fifteen mothers were in the experimental group and seventeen were in the control group. A workbook program was provided twice during a period from two-three days after the baby's admission to one week after the first intervention. The instruments used were the PSS and self confidence scale. Data was analyzed by means of frequency, SD, $x^2-test$, Fisher's exact test, Mann-Whitney test, and the Wilcoxon signed rank test. Result: There was a significant difference in perceived stress levels between the experimental and control group (U=2.366, p=.018). There was not a significant difference in maternal role confidence between the two groups (U=1.002, p=.316). There was a significant difference in breastfeeding practice between the two groups ($x^2=4.910$, p=.035). Conclusion: It is concluded that a program using a workbook has a positive effect on decreasing the perceived stress level and increasing breastfeeding practice.