• 제목/요약/키워드: Two-Phase Natural Convection

검색결과 33건 처리시간 0.03초

비선형 열원모델을 이용한 Rijke tube 내열음향 불안정 곡선의 수치예측기법 (Numerical Prediction of Thermoacoustic Instability in Rijke Tube Using Non-linear Model for Heat Source)

  • 송우석;이승배
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2524-2529
    • /
    • 2008
  • The thermal system like a combustion chamber is believed to experience a significant instability problem with vibration in case that the thermal energy or the acoustic energy are transformed into a different form through a relevant path. This study deals with a numerically- predicted, Thermoacoustic instability in a Rijke tube by using a non-linear model for a heat source. The heating part where the energy transformation occurs actively is modeled after simulating two-dimensional cylinder case with constant surface temperature, and a nonlinear model that accounts for the transfer function of magnitude- and phase-characteristics is properly implemented so as to be dependent on the pulsation strength in the tube. The heat source model is observed to result in equivalent Thermoacoustic instabilities in the Rijke tube except low flow-rate cases in which the natural convection is dominant.

  • PDF

나노유체 토로이달 자연대류 루프에서의 열전달 특성 (Heat Transfer Characteristics on Toroidal Convection Loop with Nanofluids)

  • 장주찬;이석호;이충구
    • 대한기계학회논문집B
    • /
    • 제33권4호
    • /
    • pp.235-241
    • /
    • 2009
  • Experimental studies on single-phase toroidal circulation loop(thermosyphon) have been performed in the present study with Ag-nanofluids as a working fluids. The present paper deals with an experimental study on the heat transfer behavior of single-phase toroidal loop. Toroidal loop charged with nanofluid has been constructed and a number of tests have been carried out. Different geometric parameter, e.g., orientation has been investigated. The tests were conducted employing two fluids: distilled water and Ag-nanofluid of various volume concentrations. The experiments at Rayleigh number from $10^5$ to $10^6$ showed a systematic and slight deterioration in natural convective heat transfer. It was observed that the deterioration due to the particle concentration was in the range of 5-10%. At a given particle concentration of 0.05%, abrupt decrease in the Nusselt number and the Raleigh number was observed. The present study with toroidal loop shows that the application of nanofluids for heat transfer intensification should not be decided only by the effective thermal conductivity with increasing particle concentration.

The Effect of Coolant Boiling on the Molten Metal Pool Heat Transfer with Local Solidification

  • Cho, Jea-Seon;Kune Y. Suh;Chung, Chang-Hyun;Park, Rae-Joon;Kim, Sang-Baik
    • Nuclear Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.34-45
    • /
    • 2000
  • This study is concerned with the experimental test and numerical analysis of the heat transfer and solidification of the molten metal pool with overlying coolant with boiling. In the test, the metal pool is heated from the bottom surface and coolant is injected onto the molten metal pool. Experiments were performed by changing the test section bottom surface temperature of the metal layer and the coolant injection rate. The two-phase boiling coolant experimental results are compared against the dry test data without coolant or solidification of the molten metal pool, and against the crust formation experiment with subcooled coolant. Also, a numerical analysis is performed to check on the measured data. The numerical program is developed using the enthalpy method, the finite volume method and the SIMPLER algorithm. The experimental results of the heat transfer show general agreement with the calculated values. The present empirical test and numerical results of the heat transfer on the molten metal pool are apparently higher than those without coolant boiling. This is probably because this experiment was performed in concurrence of solidification in the molten metal pool and the rapid boiling of the coolant. The other experiments were performed without coolant boiling and the correlation was developed for the pure molten metal without phase change.

  • PDF

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: An experimental study

  • Qiuping Lv;Matthew Jasica;Darius Lisowski;Zhiee Jhia Ooi;Rui Hu;Mitch Farmer
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.655-665
    • /
    • 2024
  • The objective of the present experimental study is to investigate the effect of inlet throttling on the thermohydraulic stability of a large scale water-based Reactor Cavity Cooling System (RCCS). The test was performed using the water-based Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne, which represented a ½ axial scale and 12.5° sector slice of the full scale Framatome 625 MWt SC-HTGR RCCS concept. A two-phase steady state was first established through direct condensate refill, followed by increased inlet throttling over 10 stages, corresponding to a loss coefficient K over the range of 0.05-653. With the inlet throttling gradually increased, the system experienced a unique transition process between stabilization and destabilization. Through a stability analysis, three instability mechanisms were identified in the present test, including a compound mechanism due to both natural circulation oscillations (NCOs) and density wave oscillations (DWOs), Type-II DWOs, and geysering.

유해가스 및 분진이 발생하는 작업장내의 자연환기에 대한 연구 (The Study on Natural Ventilation in Working Places with the Noxious Gas and Dust)

  • 추병길;김철;최종욱;유수열
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.72-79
    • /
    • 2000
  • In recent, occupational diseases in harmful working places become a social issue. It is the well-known fact that a respiration in polluted working places exert a serious effect on health of workers. Accordingly, the cutting off contaminants air originally is the best way to improve working environments. In these cases, ventilation systems should be essentially installed to dilute or exhaust the contaminated indoor air. In this study, we investigated the characteristics of ventilation system of the noxious gas in working indoor places with natural ventilation by using COMET. The numerical simulations were carried out the natural ventilation with two phase(air, dust). For turbulent flow, Reynolds stresses were closed by the standard $\kappa$-$\varepsilon$ model. The results are as follows ; 1) In the natural exhaust in the working place, the flows of the central region have a more rapid velocity vector than the right and left one. 2) Numerical results show that the distribution of contaminants concentration have greater influence on convection than the case of diffusion by government of velocity vectors. 3) To observe the velocity variation with distance, three location of distance are considered. As results, it shows that the velocity are 0.075(m/s) at y=5(m), 10(m) and mean concentration are raised 10.6% at y=5(m), 10(m). 4) We have presented the useful data for the adequate counterplan in the harmful working places by carrying out the various investigation of the natural ventilation.

  • PDF

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

  • Wu, Xiangcheng;Yan, Changqi;Meng, Zhaoming;Chen, Kailun;Song, Shaochuang;Yang, Zonghao;Yu, Jie
    • Nuclear Engineering and Technology
    • /
    • 제48권6호
    • /
    • pp.1321-1329
    • /
    • 2016
  • To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from $450^{\circ}C$ to $700^{\circ}C$ and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

2상 유동 해석코드 CUPID를 이용한 CANDU 원자로 감속재 열수력 예비해석 (Preliminary Analysis of the CANDU Moderator Thermal-Hydraulics using the CUPID Code)

  • 박상기;이재룡;윤한영;김형태;정재준
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.419-426
    • /
    • 2012
  • 본 연구에서는 기기 스케일 2상 유동(Two-phase flow) 해석 코드 CUPID를 사용하여 CANDU 원자로의 칼란드리아 용기 내부 감속재의 열수력 거동을 분석하기 위한 사전연구를 수행하였다. 먼저, Stern 연구소에서 수행한 단상유동 실험 3종류를 이용하여 CUPID 코드를 검증하였다. 칼란드리아 관다발 영역 격자생성의 복잡성을 피하기 위하여 다공성 매질 모델을 해당 영역에 적용하였고, 다공성 매질 영역의 유동 저항은 실험에서 얻은 관계식을 이용하여 계산하도록 하였다. 계산결과, CUPID 코드는 칼란드리아 용기 내부의 강제 및 자연 대류의 혼합 유동 양식을 성공적으로 예측하였다. 다음으로 2상 유동이 발생하는 경우를 해석하였다. 이들 계산을 통해 CUPID 코드의 CANDU 원자로 감속재 해석 능력을 보였다. 또한, 국부 과냉각 여유도를 예측하는데 사용할 수 있는 유입유량 대비 칼란드리아 용기의 국부 최대 감속재 온도 그래프를 제시하였다.

에너지 축열보드 열해석을 위한 컴퓨터 수치해석 (Computer Simulation for the Thermal Analysis of the Energy Storage Board)

  • 강용혁;엄태인;곽희열
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.224-232
    • /
    • 1999
  • 캡슐형 잠열재를 이용한 열저장 시스템은 바닥 난방 및 건물 난방에서 매우 효과적인 시스템이다. 이러한 시스템 개발에 필수적인 요소가 열유동 매체가 순환하는 파이프 주변의 캡슐내 온도 분포와 열유동 매체의 유량 등이다. 그러므로 본 연구에서는 3차원 비정상 상태에서 Navier-Stokes 방정식, 난류모델을 비롯한 스칼라 보존 방정식을 적용하여 캡슐 블록의 온도 분포 및 파이프 내의 유동장 해석을 수행하였다. 또한 본 연구와 같이 계산 영역이 특별한 기하학적 현상을 형상(circle+square)인 문제 해결하는데 적용할 수 있는 새로운 격자 생성 기술(MBFGE/CCM)을 개발하였다. 격자계는 파이프에서 원형 격자를 이용하였고, 캡슐 블록에서 사각 격자를 이용하여 다중격자와 미세격자를 결합하여 사용하였다. 본 연구의 목적은 컴퓨터를 이용한 수치해석적 방법을 미세 캡슐을 이용한 축열보드에 적용하여 2종류의 열경계 상태에 대하여 속도와 온도분포를 계산하여 비교분석을 하는 것이다. 온도는 축열 보드의 한 쪽면은 대류면이고 다른 한쪽면은 단열면인 경우(Case 2)보다 양면 모두 단열인 경우(Case 1)일 때 더 높게 상승하였다. 온수 파이프 중심선인 Y=0 에 가까운 영역에서 Case 1과 Case 2사이에 축열 보드 내에서 온도 차이는 확연하게 나타났다. 향후 수치해석의 정확도를 높이고 축열 보드의 열전달 현상을 보다 정확히 계산하기 위해서는 위치 및 시간에 따른 정밀한 온도 측정값이 필요하고 특히 잠열재인 미세 캡슐이 상변화를 하므로 온도 변화에 따른 물질의 비열(C$_{p}$)과 열전달율(λ)을 고려한 방정식이 요구된다.

  • PDF

Stability of the growth process at pulling large alkali halide single crystals

  • V.I. Goriletsky;S.K. Bondarenko;M.M. Smirnov;V.I. Sumin;K.V. Shakhova;V.S. Suzdal;V.A. Kuznetzov
    • 한국결정성장학회지
    • /
    • 제13권1호
    • /
    • pp.5-14
    • /
    • 2003
  • Principles of a novel pulse growing method are described. The method realized in the crystal growing on a seed from melts under raw melt feeding provided a more reliable control of the crystallization process when producing large alkali halide crystals. The slow natural convection of the melt in the crucible at a constant melt level is intensified by rotating the crucible, while the crystal rotation favors a more symmetrical distribution of thermal stresses over the crystal cross-section. Optimum rotation parameters for the crucible and crystal have been determined. The spatial position oi the solid/liquid phase interface relatively to the melt surface, heaters and the crucible elements are considered. Basing on that consideration, a novel criterion is stated, that is, the immersion extent of the crystallization front (CF) convex toward the melt. When the crystal grows at a <> CF immersion, the raised CF may tear off from the melt partially or completely due to its weight. This results in avoid formation in the crystal. Experimental data on the radial crystal growth speed are discussed. This speed defines the formation of a gas phase layer at the crystal surface. The layer thickness il a function of time a temperature at specific values of pressure in the furnace and the free melt surface dimensions in the gap between the crystal and crucible wall. Analytical expressions have been derived for the impurity component mass transfer at the steady-state growth stage describing two independent processes, the impurity mass transfer along the <> path and its transit along the <> one. The heater (and thus the melt) temperature variation is inherent in any control system. It has been shown that when random temperature changes occur causing its lowering at a rate exceeding $0.5^{\circ}C/min$, a kind of the CF decoration by foreign impurities or by gas bubbles takes place. Short-term temperature changes at one heater or both result in local (i.e., at the front) redistribution of the preset axial growth speed.

실험과 수치해석을 통한 동토지반 안정화용 수직형 열사이펀의 성능평가 (Experimental and Numerical Investigation of the Performance of Vertical Thermosyphon for Frozen Ground Stabilization)

  • 이장근;이철호;장창규;최창호
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.45-56
    • /
    • 2014
  • 한대지역은 계절 변화에 따라 동결융해가 반복되는 상부의 활동층과 하부의 영하상태로 항시 유지되는 영구동토층으로 구성되어 있다. 한대지역에서 여름철에는 동결되어 있는 지반을 융해시키기 때문에 지반 강도저하 및 침하가 발생한다. 이러한 강도저하 및 침하는 상부 구조물의 구조적 안정성에 문제를 야기시켜 활동층을 포함하고 있는 한대지역에서는 지반의 온도를 항시 영하상태로 유지할 수 있는 동결지반 안정화 공법이 필요하다. 열사이펀이란 구조체 내부에 충전된 냉매의 자가적인 열순환에 의해 지반의 온도를 항시 영하상태로 유지할 수 있는 지반 안정화 공법 이다. 본 연구에서는 열사이펀의 지반 동결성능을 분석하기 위해 R-134a 냉매를 이용하여 충전율에 따른 열사이펀의 지반 온도제어를 실내실험과 수치해석을 통해 분석하고 열사이펀의 열전도율을 산정하였다.