• Title/Summary/Keyword: Two transformer

Search Result 556, Processing Time 0.03 seconds

Differential Driving of Inverter for High Uniformity LCD TV Backlight (LCD TV용 고균일도 백라이트 구동을 위한 Differential Driving 인버터)

  • Chun Young Tea;Lim Sungkyoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.37-41
    • /
    • 2004
  • Parallel combination of cold chathode fluorescent lamps (CCFL) are widely used as the light sources of LCD TV backlight. Brightness uniformity is safisfied by using one transformer per one CCFL. Instead of using one transformer per oneCCFL, one transformer is used to drive 8 CCFLs by using differential driving method. A differential driving inverter with two transformers is developed to drive 16 CCFLs of 26' backlight for LCD TV. The brightness uniformity of $88\%$ was obtained by driving 26' backlight with the developed differential driving inverter successfully.

  • PDF

High Efficiency and Small Size Switch Mode Line Transformer(SMLT) (고효율 및 소형 스위치모드 라인 트랜스포머)

  • Kim, Jin-Hong;Yang, Jung-Woo;Jang, Du-Hee;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.237-243
    • /
    • 2019
  • A high-efficiency and small-sized switched-mode line transformer (SMLT) is proposed in this study. The conventional structure of an adapter is composed of line transformer and rectifiers. This structure has a limit in miniaturizing due to low-frequency line transformer. Another structure is composed of power factor correction (PFC) and DC/DC converter. This structure has a limit in reducing volume due to two-stage structure. As the proposed SMLT is composed of an LLC resonant converter, a high-frequency transformer can be adopted to achieve isolation standards and size reduction. This proposed structure has different operation modes in accordance with line input voltage to overcome poor line regulation. In addition, the proposed SMLT is applied to the front of a conventional PFC converter, because the SMLT output voltage is restored to rectified sinusoidal wave by using a full-bridge rectifier in the secondary side. The design of the PFC converter is easy, because the SMLT output voltage is controlled as rectified sinusoidal wave. The validity of the proposed converter is proven through a 350 W prototype.

Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench (이중퀜치를 이용한 삼상변압기형 한류기의 고장전류제한 동작 분석)

  • Han, Tae-Hee;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.184-189
    • /
    • 2022
  • In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.

The decision of position of a partial discharge in power transformer by measurement of ultra sonic signal (초음파 신호측정에 의한 변압기내의 부분방전위치측정)

  • 문영재
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.87-90
    • /
    • 1992
  • Detecting acoustic emission (AE) provides an appropriate method to diagonize on-line transformers, since acoustic signal is not influenced by strong electric field. Then AE versus AE signal processing method is investigated. But this processing is difficult that decision of starting point of AE wave with acoustic noise. This problem is sloved by correlation which calculate time interval between two signals eactly. This paper presents a technique locating the eact position of the partial discharge (PD) in a power transformer by the correlation of the AE signals from two ultrasonic sensors. And PD position is displayed on monitor. Laboratory tests confirmed that the proposed method can be used for locating the PD in power transformer.

  • PDF

Implementation for Partial Discharge Detection using Ultrasonic Signal (초음파 신호를 이용한 부분방전 검출 장치 개발에 관한 연구)

  • Choi, S.A.;Chung, H.H.;Kwak, H.R.;Kim, J.C.;Chung, S.J.;Yoon, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.588-590
    • /
    • 1993
  • This paper presents a diagnostic technique using ultrasonic for operating power transformer. Two methods are used as a base for detecting a partial discharge. One is a analysis of PD trend using counted ultrasonic signal, the other is a estimation of PD location source using cross-correlation. In this paper we implement detection equipment of partial discharge in power transformer. The desired system is utilized to two methods for PD detection and operated by graphical user interface(GUI). The results of test showed that the system can be adopted to real power transformer.

  • PDF

A Study on Design and Analysis of Piezoelectric Transformer for Resonance Mode (공진모드의 변화에 따른 압전변압기의 특성에 관한 연구)

  • 정현호;이상기;박태곤;김명호;이원재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.432-435
    • /
    • 2000
  • This paper present a new sort of multilayer piezoelectric ceramic transformer for the application to AC-adapters. This piezoelectric transformers operate in the second and third length extensional vibration mode. And the output performance of two types of piezoelectric transformers are compared by ANSYS, which is one of the FEM analysis program. As a result the minimum displacement was occurred at the two points in second length extensional vibration mode and three point in third length extensional vibration mode. One is the middle of input and the other is middle of output parts. And output voltage was inversely decreased by increasing number of output layers. Also The third mode type is shown higher power transition ratio than the second mode type.

  • PDF

Fabrication and Operation Testing of an Air-cored Pulse Transformer for Charging a High Voltage Pulse Forming Line (고압 펄스 성형라인 충전을 위한 공심형 고압 펄스트랜스의 제작과 동작 특성)

  • Jin, Yun-Sik;Kim, Young-Bae;Kim, Jong-Soo;Ryoo, Hong-Je;Cho, Chu-Hyun;Rim, Geun-Hee;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.939-944
    • /
    • 2010
  • A high voltage air-cored helical strip/wire type pulse transformer has been fabricated for charging of a high voltage pulse forming line. As a primary coil, copper strip of 25mm width was wound helically around a MC nylon cylinder. For a secondary coil, copper enameled wire of 1mm diameter was wound around conical cylinder in order to provide insulation between two windings. The coupling coefficient of 0.53 was obtained when two coils were combined coaxially in the insulation oil filled chamber. Voltage gain and energy transfer efficiency were investigated by varying the parameters of primary and secondary circuit. Test results shows that the voltage gain increases up to 17 with increasing the primary capacitance up to 200nF. And highest energy transfer efficiency of 44% was obtained when the dual resonant operation condition was nearly satisfied. The pulse transformer developed in this study can be used for charging the middle conductor of a Blumlein pulse forming line.

Hyperparameter experiments on end-to-end automatic speech recognition

  • Yang, Hyungwon;Nam, Hosung
    • Phonetics and Speech Sciences
    • /
    • v.13 no.1
    • /
    • pp.45-51
    • /
    • 2021
  • End-to-end (E2E) automatic speech recognition (ASR) has achieved promising performance gains with the introduced self-attention network, Transformer. However, due to training time and the number of hyperparameters, finding the optimal hyperparameter set is computationally expensive. This paper investigates the impact of hyperparameters in the Transformer network to answer two questions: which hyperparameter plays a critical role in the task performance and training speed. The Transformer network for training has two encoder and decoder networks combined with Connectionist Temporal Classification (CTC). We have trained the model with Wall Street Journal (WSJ) SI-284 and tested on devl93 and eval92. Seventeen hyperparameters were selected from the ESPnet training configuration, and varying ranges of values were used for experiments. The result shows that "num blocks" and "linear units" hyperparameters in the encoder and decoder networks reduce Word Error Rate (WER) significantly. However, performance gain is more prominent when they are altered in the encoder network. Training duration also linearly increased as "num blocks" and "linear units" hyperparameters' values grow. Based on the experimental results, we collected the optimal values from each hyperparameter and reduced the WER up to 2.9/1.9 from dev93 and eval93 respectively.

2.4-GHz Power Amplifier with Power Detector Using Metamaterial-Based Transformer-Type On-Chip Directional Coupler

  • Dang, Trung-Sinh;Tran, Anh-Dung;Lee, Bomson;Yoon, Sang-Woong
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.554-557
    • /
    • 2013
  • This letter presents a power amplifier (PA) with an on-chip power detector for 2.4-GHz wireless local area network application. The power detector consists of a clamp circuit, a diode detector, and a coupled line directional coupler. A series inductor for an output matching network in the PA is combined with a through line of the coupler, which reduces the coupling level. Therefore, the coupler employs a metamaterial-based transformer configuration to increase coupling. The amount of coupling is increased by 2.5 dB in the 1:1 symmetric transformer structure and by 4.5 dB from two metamaterial units along the coupled line.

Study on Coil Insulation of HTS Transformer with Simulated Electrode (고온초전도 코일의 모의 전극계에서의 절연연구)

  • 정종만;백승명;이정원;곽동순;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.420-423
    • /
    • 2002
  • In this paper the characteristics of surface flashover for high temperature superconducting transformer(HTS) was discussed. The transformer, will be developed in the shell type with double pancake coil, isn't developed yet in the world. We conducted experiment of surface flashover that could occur in the windings of the transformer. First, we distinguished the surface flashover with electrode alignment into two type, such as parallel and vertical, and then compared with each characteristics of surface flashover. And the surface flashover with metallic particle was tested, it was also affected by the particle position. .

  • PDF