• 제목/요약/키워드: Two transformer

검색결과 552건 처리시간 0.027초

Voltage-Fed Push-Pull PWM Converter Featuring Wide ZVS Range and Low Circulating Loss with Simple Auxiliary Circuit

  • Ye, Manyuan;Song, Pinggang;Li, Song;Xiao, Yunhuang
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.965-974
    • /
    • 2018
  • A new zero-voltage-switching (ZVS) push-pull pulse-width modulation (PWM) converter is proposed in this paper. The wide ZVS condition for all of the switches is obtained by utilizing the energy stored in the output inductor and magnetizing inductance. As a result, the switching losses can be dramatically reduced. A simple auxiliary circuit including two small diodes and one capacitor is added at the secondary side of a high frequency (HF) transformer to reset the primary current during the circulating stage and to clamp the voltage spike across the rectifier diodes, which enables the use of low-voltage and low-cost diodes to reduce the conducting and reverse recovery losses. In addition, there are no active devices or resistors in the auxiliary circuit, which can be realized easily. A detailed steady operation analysis, characteristics, design considerations, experimental results and a loss breakdown are presented for the proposed converter. A 500 W prototype has been constructed to verify the effectiveness of the proposed concept.

무효전력을 보상하는 축소형 ITER 전원공급장치의 순차제어 (Sequence Control of Small-scaled ITER Power Supply for Reactive Power Compensation)

  • 허혜성;박기원;안현식;장계용;신현석;최정완;오종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.932_933
    • /
    • 2009
  • A technology based on thyristors will be used to manufacture the super-conducting coil AC/DC converters because of the low ratio of cost over installed power compared to a design based on GTO or similar technology. But phase-controlled converter suffers from fundamental disadvantage. They inject current harmonics into the input ac mains due to their nonlinear characteristics, thereby distort the supply voltage waveform, and demand reactive power from the associated ac power system at retarded angles. To overcome this disadvantage, in the case of two series converters at the DC side, connected to the same step-down transformer, apply for the sequence control. It is the most simple and efficient way to reduce the reactive power consumption at low cost. Analytical sequence control algorithm is suggested, the validity of the proposed scheme has been verified by experimental results with the small-scaled International Thermonuclear Experimental Reactor (ITER) Power Supply to minimize reactive power consumption.

  • PDF

$SF_6/N_2$ 혼합기체의 대기압 플라즈마 특성 분석 (The Analysis of $SF_6/N_2$ Plasma Properties Under the Atmosphere Pressure)

  • 소순열;이진
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.516-520
    • /
    • 2009
  • Atmosphere Plasmas of Gas Discharge (APGD) have been used in plasma sources for material processing such as etching, deposition, surface modification, etc. This study is to investigate and understand the fundamental plasma discharge properties. Especially, $SF_6/N_2$ mixed gas would be used in power transformer, GIS (Gas insulated switchgear) and so on. In this paper, we developed a one dimensional fluid simulation model with capacitively coupled plasma chamber at the atmosphere pressure (760 [Torr]). 38 kinds of $SF_6/N_2$ plasma particles which are an electron, two positive ions (${SF_5}^+$, ${N_2}^+$), five negative ions (${SF_6}^-$, ${SF_5}^-$, ${SF_4}^-$, ${F_2}^-$, ${F_1}^-$), thirty excitation and vibrational particles for $N_2$ were considered in this computation. The $N_2$ gases of 20%, 50%, 80% were mixed in $SF_6$ gas. As the amount of $N_2$ gas was increased, the properties of electro-negative plasma moved toward the electro-positive plasma.

배전계통 기기 유지보수를 위한 RCM 모델 (Reliability-Centered Maintenance Model for Maintenance of Electric Power Distribution System Equipment)

  • 문종필;손진근
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.410-415
    • /
    • 2009
  • With the implementation of electric power industry reform, the utilities are looking for effective ways to improve the economic efficiency. One area in particular, the equipment maintenance, is being scrutinized for reducing costs while keeping a reasonable level of the reliability in the overall system. Here the conventional RCM requires the tradeoff between the upfront maintenance costs and the potential costs of losing loads. In this paper we describe the issues related to applying so-called the "Reliability-centered Maintenance" (RCM) method in managing electric power distribution equipment. The RCM method is especially useful as it explicitly incorporates the cost-tradeoff of interest, i.e. the upfront maintenance costs and the potential interruption costs, in determining which equipment to be maintained and how often. In comparison, the "Time-based Maintenance" (TBM) method, the traditional method widely used, only takes the lifetime of equipment into consideration. In this paper, the modified Markov model for maintenance is developed. First, the existing Markov model for maintenance is explained and analyzed about transformer and circuit breaker, so on. Second, developed model is introduced and described. This model has two different points compared with existing model: TVFR and nonlinear customer interruption cost (CIC). That is, normal stage at the middle of bathtub curve has not CFR but the gradual increasing failure rate and the unit cost of CIC is increasing as the interruption time is increasing. The results of case studies represent the optimal maintenance interval to maintain the equipment with minimum costs. A numerical example is presented for illustration purposes.

넓은 충전 범위를 갖는 전기 자동차용 급속 충전기의 고효율 운전을 위한 손실 분석 (Power Loss Analysis of EV Fast Charger with Wide Charging Voltage Range for High Efficiency Operation)

  • 김대중;박진혁;이교범
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1055-1063
    • /
    • 2014
  • Power losses of a 1-stage DC-DC converter and 2-stage DC-DC converter are compared in this paper. A phase-shift full-bridge DC-DC converter is considered as 1-stage topology. This topology has disadvantages in the stress of rectifier diodes because of the resonance between the leakage inductor of the transformer and the junction capacitor of the rectifier diode. 2-stage topology is composed of an LLC resonant full-bridge DC-DC converter and buck converter. The LLC resonant full-bridge DC-DC converter does not need an RC snubber circuit of the rectifier diode. However, there is the drawback that the switching loss of the buck converter is large due to the hard switching operation. To reduce the switching loss of the buck converter, SiC MOSFET is used. This paper analyzes and compares power losses of two topologies considering temperature condition. The validity of the power loss analysis and calculation is verified by a PSIM simulation model.

인터리브 방식을 이용한 전기자동차용 고효율 승압형 양방향 DC/DC 컨버터 개발 (Development of Boost Type Bidirectional DC/DC Converter with High Efficiency For EV using an Interleave Method)

  • 최정식;오승열;정동화;송성근
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.59-68
    • /
    • 2013
  • This paper proposes the boost type bidirectional DC/DC converter with high efficiency for electric vehicle using an interleave method. This interleave method can reduce the system size because it reduces the ripple of output voltage and input current with no add to extra filter. Proposed system is consist of two converters and applies to interleaved method through phase shift to each converter. And it implements the high boost through voltage double and series construction of output port. Also, it reduces the price and increases the efficiency as operating the ZCS by leakage inductance of transformer and capacitor of voltage double with not add special reactor. Proposed DC/DC converter using interleave method is proved the validity through the result of PSIM simulation and experiment of 5kW DC/DC converter.

A Zero Voltage Switching Phase Shift Full Bridge Converter with Separated Primary Winding

  • Kim, Young-Do;Kim, Chong-Eun;Cho, Kyu-Min;Park, Ki-Bum;Cho, In-Ho;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.379-381
    • /
    • 2008
  • Generally additional leakage inductance and two clamp diodes are adopted into the conventional phase shift full bridge (PSFB) converter for reducing the voltage stress of secondary rectifier diodes and extending the range of zero voltage switching (ZVS) operation. However, since additional leakage inductance carries the ac current similar to the primary one, the core and copper loss oriented from additional leakage inductance can be high enough to decrease the whole efficiency of DC/DC converter. Therefore, in this paper, a new ZVS phase shift full bridge converter with separated primary winding (SPW) is proposed. Proposed converter makes the transformer and additional leakage inductor with one ferrite core. Using this method, leakage inductance is controlled by the winding ratio of separated primary winding. Moreover, by manufacturing the both magnetic components with one core, size and core loss can be reduced and it turns out the improvement of efficiency and power density of DC/DC converter. The operational principle of proposed converter is analyzed and verified by the 1.2kW prototype.

  • PDF

Resonant Tank Design Considerations and Implementation of a LLC Resonant Converter with a Wide Battery Voltage Range

  • Sun, Wenjin;Wu, Hongfei;Hu, Haibing;Xing, Yan
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1446-1455
    • /
    • 2015
  • This paper illustrates resonant tank design considerations and the implementation of a LLC resonant converter with a wide battery voltage range based on the fundamental harmonic approximation (FHA) analysis. Unlike the conventional design at zero load, the parameter K (the ratio of the transformer magnetizing inductor Lm to the resonant inductor Lr) of the LLC converter in this paper is designed with two charging points, (Vo_min, Io_max1) and (Vo_max, Io_max2), according to the battery charging strategy. A 2.9kW prototype with an output voltage range of 36V to 72V dc is built to verify the design. It achieves a peak efficiency of 96%.

YBCO의 직렬연결에 따른 자속구속형 초전도 한류기의 퀜치특성 (Quench Characteristics of Flux-Lock Type Superconducting Fault Current Limiter According to The Number of YBCO)

  • 이상일;박형민;최효상
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권8호
    • /
    • pp.329-333
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) depending on the number of the serial connection between the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting elements in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity windings depending on the winding directions between the primary and secondary coils. In this paper, the analyses of voltage, current, and resistance of superconducting elements in serial connection were performed to increase the power capacity of flux-lock type SFCL. The power burden was reduced through the simultaneous quenching between the superconducting elements. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

Z-원 승압인버터를 이용한 변압기 없는 DGS제어 (Transformerless DGS Control using a Z-source Boost Inverter)

  • 박영산
    • 한국정보통신학회논문지
    • /
    • 제10권9호
    • /
    • pp.1617-1624
    • /
    • 2006
  • 본 논문은 분산전원시스템(DGS)을 위 한 시스템 모델링, 수정된 SVPWM 적용 그리고 수동소자인 L과 C로 구성된 Z-원 인버터의 제어기에 대하여 기술하였다. 기존의 DC/DC 승압 컨버터나 변압기를 사용하지 않고 낮은 DC 입력을 상용 AC로 만들기 위해서 SVPWM의 영벡터 구간을 이용해 DC-링크단 전압을 승압하는데 이용하였다. 한 스위칭주기에 3개조의 스위칭소자 중에 2개조만 동시 도통되도록 하여 유효벡터의 손실 없이 승압이 가능하도록 하였다. 빠르고 오버슈트가 없는 전류응답과 낮은 정상상태 전압오차를 얻기 위해서 이산시간 슬라이딩모드 전류제어기와 강인한 서보기구 전압제어기를 설계하였다. 시뮬레이션을 통하여 제안된 알고리즘의 유용성을 확인하였다.