• Title/Summary/Keyword: Two line method

Search Result 2,117, Processing Time 0.034 seconds

Temperature control of a batch PS polymerization reactor using on-line two-step method (온라인 2단계 방법을 이용한 회분식 PS 중합반응기의 온도제어)

  • 이병모;노형준;이현구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.305-308
    • /
    • 1997
  • The on-line calculation method is developed to obtain the temperature trajectory that brings the reactants to the desired state in batch styrene polymerization reactor. The temperature trajectory is obtained by applying the moments of the polymer concentration to the 2-step calculation method. The computer simulation is also carried out to verify the superiority of the on-line method to the off-line one. When a temperature disturbance of constant size is introduced, the off-line results shows considerable deviation from the target degree of polymerization. The on-line strategy set up a new trajectory to reach the desired state by using the current state of the reactor. Therefore, the on-line strategy deals with the changes of the system more adequately than the off-line strategy.

  • PDF

Comparision of two cephalometric superimposition methods - Nasion-sella line method and Anterior cranial base method (두가지 두부 방사선 사진 중첩 방법의 비교 - Nasion-Sella line 중첩과 Anterior cranial base 중첩)

  • Kyung, Seung-Hyun;Moon, Yon-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.633-641
    • /
    • 1997
  • Spatial change of craniofacial structures from growth or orthopedic force is usually evaluated by cephalometric superimpositions at different points in time.As the evaluation cu be changed according to cephalometric superimposition method,selettion for correct superimposition method is very important.Double registration of nineteen pairs of female lateral head films,their growth period is average 3.7 years and age is overage 10.7 years,were performed by two observers.Comparisions was made between two methods and the results revealed the following, 1. NS line and ACB superimpositions ate not markedly different in reliability due to almost same registration error of them. 2. The investigation was undertaken to examine interobserver difference.In NS line method, there is no significance in all measurements. In ACB method,significant difference was revealed in 4 measurements of 7 measurements was 3. In the investigation of intermethod difference, there is no significance between NS line and ACB superimpositions

  • PDF

Clinical Effect of Bong Chuna Manual Therapy and Acupunture Treatment for Improving Cervical Curvature of Turtle Neck Syndrome and Measurement Method of Radiography (거북목증후군의 경추만곡 호전에 대한 봉추나요법과 침술의 효과와 방사선학적 평가방법 연구)

  • Oh, Won-Kyo;Lee, Eugune;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.1
    • /
    • pp.113-124
    • /
    • 2009
  • Objectives : The aim of this study was to observe the effect of Bong Chuna manual therapy(BCMT) and acupuncture on the Turtle Neck Syndrome(TNS) by the changes of radiological findings and symptoms. Methods : Total twenty-eight patients diagnosed as TNS were evaluated. Twenty patients in experimental group were treated by the combination of BCMT and acupuncture, eight patients in control group were treated by acupuncture only. We measured VAS(Visual analogue scale) as pain intensity and Neck Pain and Disability Scale(NDI) at pre- and post-treatment. Also the four line Cobb's method and Jochumsen method were assessed for evaluating the radiographical changes, additionally we used 'two line method'. Results : VAS score showed statistically significant reduction in pain intensity in both experimental group and control group after 8 weeks treatment, $-44.05{\pm}14.91$ vs $-23.75{\pm}14.08$ respectively. Also NDI score presented $-11.40{\pm}8.63$ reduction in experimental group, and it was significant statistically, however not in control group, $-8.63{\pm}9.84$ reduction after 8weeks treatment. In radiological findings, the four line Cobb's method, Jochumsen method and two line method were reduced after 8weeks treatment, $-9.30{\pm}10.33$, $-0.65{\pm}1.72$ and $-14.35{\pm}5.68$ in experimental group respectively, $-0.75{\pm}1.91$, $-0.25{\pm}0.71$ and $0.38{\pm}2.20$ in control group respectively. However they were statistical significance only in the four line Cobb's method and two line method in both group. Conclusions : Combination treatment of CMT and acupuncture showed better effect on pain reduction, VAS score and the correction of neck anteversion than acupuncture only in TNS. Two line method seems valuable for evaluating the improvement of radiographical changes in TNS.

On-line signature verification method using Gabor filter (Gabor 필터를 이용한 온라인 서명 검증 기법)

  • 이종현;김성훈;김재희
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.129-137
    • /
    • 2004
  • This paper presents a signature verification method that uses Gabor filter in computing similarity between signatures. In computing similarity to compare two on-line signatures, the temporal relationship between two signatures should be computed in advance. However, conventional point matching method using DP(dynamic programming) matching consumes much computation. In this paper, we propose a fast method for computing the temporal relationship between two on-line signatures by using the phase output of Gabor Inter applied on the on-line signature signals. Two similarity measures are defined in the method: Temporal Similarity and Temporally Arranged Feature Profile Similarity. With the proposed method, Ive could compare signatures 30 times faster than conventional method using DP matching.

Waveform Detection Algorithm based on the Search of Distinctive Line-Segments (검색에 기초한 파형 검출 알고리듬)

  • 박승훈;장태규
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.265-272
    • /
    • 1993
  • We present a new waveform detection method, based on the search of distinctive line-segments. The method is based on the basic assumption that the waveform morphology of biological signals is readily characterized by a sequence of the distinctive line-segments and their structural features. In this method, the distinctive line-segments are first searched for, and a structural feature analysis is performed an the distinctive line-segments found. Experiments of detecting epileptic spikes were carried out to evaluate the detection per formance of the method. Two subjects were used for training and tuning the algorithm and four subjects for testing the method. The results were obtained on two different performance indices, detection ratio and the number of false detections per minute.

  • PDF

on-line Modeling of Nonlinear Process Systems using the Adaptive Fuzzy-neural Networks (적응퍼지-뉴럴네트워크를 이용한 비선형 공정의 온-라인 모델링)

  • 오성권;박병준;박춘성
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1293-1302
    • /
    • 1999
  • In this paper, an on-line process scheme is presented for implementation of a intelligent on-line modeling of nonlinear complex system. The proposed on-line process scheme is composed of FNN-based model algorithm and PLC-based simulator, Here, an adaptive fuzzy-neural networks and HCM(Hard C-Means) clustering method are used as an intelligent identification algorithm for on-line modeling. The adaptive fuzzy-neural networks consists of two distinct modifiable sturctures such as the premise and the consequence part. The parameters of two structures are adapted by a combined hybrid learning algorithm of gradient decent method and least square method. Also we design an interface S/W between PLC(Proguammable Logic Controller) and main PC computer, and construct a monitoring and control simulator for real process system. Accordingly the on-line identification algorithm and interface S/W are used to obtain the on-line FNN model structure and to accomplish the on-line modeling. And using some I/O data gathered partly in the field(plant), computer simulation is carried out to evaluate the performance of FNN model structure generated by the on-line identification algorithm. This simulation results show that the proposed technique can produce the optimal fuzzy model with higher accuracy and feasibility than other works achieved previously.

  • PDF

Performance Evaluation of Closed Manufacturing Systems with Sampling Inspections (샘플링 검사가 수행되는 폐쇄형 생산 시스템의 성능분석)

  • Lee, Hyo-Seong
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.22 no.1
    • /
    • pp.123-140
    • /
    • 1997
  • In this paper we consider closed flow line systems with samploing inspections. The total number of parts in the system is assumed to be N. The processings carried out of each station do not always meet the requirement of quality. Therefore, upon completion of its processing at each station, a part is inspected to determine whether the processings meet the requirement of quality or not. We assume that inspection are done on a random basis. If a part is found to be defective by an inspection, it is fed back to the apropriate station. Two different cases will be considered in this study : a three-station flow line system with infinite buffers and a two-station flow line system with finite buffers. For each case, we will develop an exact method to obtain the performance measures such as throughput, machinen utilization, average outgoing quality and manufacturing lead time. For the case of the two-station flow line system ith finite buffers, we will also develop an approximation method using a stage-aggregation technique. Then using buffers, we will also develop an approximation method using a stage-aggregation technique. Then using these results, we will try to find an optimal inspection policy which maximizes the expected net profit under a certain cost structure. Although we present the results only for the two or three station flow line system in this paper, the results obtained in this paper can be extended easily to the system which consists of more than two or three stations.

  • PDF

A Comparative Study on the Anthropometric Method - Anthropometric Point and Line - (인체측정(人體測定) 방법(方法)에 관(關)한 비교(比較) 연구(硏究) - 인체측정(人體測定) 기준점(基準點), 기준선(基準線)을 중심(中心)으로 -)

  • Kwon, Young-Ja;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.5 no.4
    • /
    • pp.89-100
    • /
    • 2001
  • The major purpose of this study is to show exact and convenient devices and minimize error in body measurement. This study was referred to 13 records and compared 6 items that the investigator's opinion has been differed about anthropometric point and line and suggested convenient and radical device, and measured by if need be. The 30 students from 20 to 25 ages were measured and data was analyzed by mean, std. deviation and paired t-test. The results are as follows. 1. Side neck point has been suggested many devices, but was suggested in this study to decide by M. trapezius, cervicale point and fossa jugularis point. 2. Shoulder point was suggested to decide by point of 1/2 armhole depth, upper arm depth and shoulder depth except acromion point. 3. Waist circumference line has been differed between horizontal line and natural line. The result of measurements was no significant difference between two methods and natural line was convenience. Waist circumference line must considered two methods together for garment construction and somato type. 4. The standard of hip circumference line has been differed between buttock point and trochanterion point. The result of measurements was significant difference between two methods, but two point must considered together because of body type. 5. Chest circumference line at scye has been differed between horizontal line and natural line. The result of measurements was significant difference between two methods and natural line was convenience. Chest circumference line at scye must studied to decide method the line for garment construction.

  • PDF

Scheduling for a Two-Machine, M-Parallel Flow Shop to Minimize Makesan

  • Lee, Dong Hoon;Lee, Byung Gun;Joo, Cheol Min;Lee, Woon Sik
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.56
    • /
    • pp.9-18
    • /
    • 2000
  • This paper considers the problem of two-machine, M-parallel flow shop scheduling to minimize makespan, and proposes a series of heuristic algorithms and a branch and bound algorithm. Two processing times of each job at two machines on each line are identical on any line. Since each flow-shop line consists of two machines, Johnson's sequence is optimal for each flow-shop line. Heuristic algorithms are developed in this paper by combining a "list scheduling" method and a "local search with global evaluation" method. Numerical experiments show that the proposed heuristics can efficiently give optimal or near-optimal schedules with high accuracy. with high accuracy.

  • PDF

A novel method to specify pattern recognition of actuators for stress reduction based on Particle swarm optimization method

  • Fesharaki, Javad Jafari;Golabi, Sa'id
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.725-742
    • /
    • 2016
  • This paper is focused on stiffness ratio effect and a new method to specify the best pattern of piezoelectric patches placement around a hole in a plate under tension to reduce the stress concentration factor. To investigate the stiffness ratio effect, some different values greater and less than unity are considered. Then a python code is developed by using particle swarm optimization algorithm to specify the best locations of piezoelectric actuators around the hole for each stiffness ratio. The results show that, there is a line called "reference line" for each plate with a hole under tension, which can guide the location of actuator patches in plate to have the maximum stress concentration reduction. The reference line also specifies that actuators should be located horizontally or vertically. This reference line is located at an angle of about 65 degrees from the stress line in plate. Finally two experimental tests for two different locations of the patches with various voltages are carried out for validation of the results.