• Title/Summary/Keyword: Twin images

Search Result 35, Processing Time 0.025 seconds

Twin-Image Elimination in In-line Digital Holography Microscope (In-line 디지털 홀로그래피 현미경에서 쌍둥이 상 제거연구)

  • Cho, Hyung-Jun;Yu, Young-Hun
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.117-121
    • /
    • 2007
  • A fundamental problem in the in-line digital holography microscope is that the real image and virtual image and zero-order image are not separated spatially. In this paper, we have eliminated the zero-order noise by an averaging method and the twin image is divided using a geometrical set-up in an in-line digital holographic microscope. The size of the virtual image depends on the distance between the objective lens and the hologram plane and on the distance between the hologram plane and the image plane. We found that the virtual image size is smallest when the distance between the objective lens and the hologram plane is equal to the back focal length of the objective lens. We could divide the virtual image and real image by controlling the distance between the hologram plane and the objective lens.

Two Cases of Bronchopulmonary Dysplasia of Similar Appearance in Adult Monozygotic Twin: Pathology and Computed Tomographic Findings

  • Lee, Yoon Pyo;Chun, Eun Mi;Kim, Yoo Kyung;Sung, Sun Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.2
    • /
    • pp.128-132
    • /
    • 2015
  • Bronchopulmonary dysplasia (BPD) is related to decreased lung function throughout life. However, the pathology and radiology pattern of BPD of adults are not documented well yet. In this case report, we present BPD case of an adult monozygotic twin showing nearly identical lesions on chest computed tomography (CT). CT images showed mixed areas of ground-glass and reticular opacities in both lungs. They had common histories of pneumonias requiring mechanical ventilations in period of infants. Pulmonary function test of one patient showed a pulmonary insufficiency with airway obstruction. Pathologic findings showed bronchiolar hyperplasia and peribronchiolar fibrosis which was similar to classic BPD patients. Our twin case report might help provide distinguishing pathology and radiology pattern of an adult pulmonary sequelaes of BPD. It might be reasonable to make close follow-up for BPD patients to evaluate the long-term outcomes of BPD survivors.

Twin-Image Noise Effects in Optical scanning Holography

  • Doh, Kyu-Bong;Lee, Hwang-Suk
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • In Optical Scanning Holography(OSH), 3-D holographic information of an object is generated by 2-D active optical scanning. The optical scanning beam can be a time-dependent Gaussian apodized Fresnel zone plate. In this technique, the holographic information manifests itself as an electric signal which can be sent to an electron-beam-addressed spatial light modulator for coherent image reconstruction. In this paper, we briefly review optical scanning holography and analyze the resolution achievable with the system. We also present mathmatical expressions of real and virtual images which are responsible for holographic image reconstruction. We then show the twin-image noise effect on the reconstruction in conjunction with the size of the Fresnel zone pattern through computer simulation.

3D Reconstruction of Structure Fusion-Based on UAS and Terrestrial LiDAR (UAS 및 지상 LiDAR 융합기반 건축물의 3D 재현)

  • Han, Seung-Hee;Kang, Joon-Oh;Oh, Seong-Jong;Lee, Yong-Chang
    • Journal of Urban Science
    • /
    • v.7 no.2
    • /
    • pp.53-60
    • /
    • 2018
  • Digital Twin is a technology that creates a photocopy of real-world objects on a computer and analyzes the past and present operational status by fusing the structure, context, and operation of various physical systems with property information, and predicts the future society's countermeasures. In particular, 3D rendering technology (UAS, LiDAR, GNSS, etc.) is a core technology in digital twin. so, the research and application are actively performed in the industry in recent years. However, UAS (Unmanned Aerial System) and LiDAR (Light Detection And Ranging) have to be solved by compensating blind spot which is not reconstructed according to the object shape. In addition, the terrestrial LiDAR can acquire the point cloud of the object more precisely and quickly at a short distance, but a blind spot is generated at the upper part of the object, thereby imposing restrictions on the forward digital twin modeling. The UAS is capable of modeling a specific range of objects with high accuracy by using high resolution images at low altitudes, and has the advantage of generating a high density point group based on SfM (Structure-from-Motion) image analysis technology. However, It is relatively far from the target LiDAR than the terrestrial LiDAR, and it takes time to analyze the image. In particular, it is necessary to reduce the accuracy of the side part and compensate the blind spot. By re-optimizing it after fusion with UAS and Terrestrial LiDAR, the residual error of each modeling method was compensated and the mutual correction result was obtained. The accuracy of fusion-based 3D model is less than 1cm and it is expected to be useful for digital twin construction.

Usefulness of Three-Dimensional Maximal Intensity Projection (MIP) Reconstruction Image in Breast MRI (유방자기공명영상에서 3 차원 최대 강도 투사 재건 영상의 유용성)

  • Kim, Hyun-Sung;Kang, Bong-Joo;Kim, Sung-Hun;Choi, Jae-Jeong;Lee, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.183-189
    • /
    • 2009
  • Purpose : To evaluate the usefulness of three-dimensional (3D) maximal intensity projection (MIP) reconstruction method in breast MRI. Materials and Methods : Total 54 breasts of consecutive 27 patients were examined by breast MRI. Breast MRI was performed using GE Signa Excite Twin speed (GE medical system, Wisconsin, USA) 1.5T. We obtained routine breast MR images including axial T2WI, T1WI, sagittal T1FS, dynamic contrast-enhanced T1FS, and subtraction images. 3D MIP reconstruction images were obtained as follows; subtraction images were obtained using TIPS and early stage of contrast-enhanced TIPS images. And then 3D MIP images were obtained using the subtraction images through advantage workstation (GE Medical system). We detected and analyzed the lesions in the 3D MIP and routine MRI images according to ACR $BIRADS^{(R)}$ MRI lexicon. And then we compared the findings of 3D MIP and those of routine breast MR images and evaluated whether 3D MIP had additional information comparing to routine MR images. Results : 3D MIP images detect the 43 of 56 masses found on routine MR images (76.8%). In non-mass like enhancement, 3D MIP detected 17 of 20 lesions (85 %). And there were one hundred sixty nine foci at 3D MIP images and one hundred nine foci at routine MR images. 3D MIP images detected 14 of 23 category 3 lesions (60.9%), 11 of 16 category 4 lesions (68.87%), 28 of 28 Category 5 lesions (100%). In analyzing the enhancing lesions at 3D MIP images, assessment categories of the lesions were correlated as the results at routine MR images (p-value < 0.0001). 3D MIP detected additional two daughter nodules that were descriped foci at routine MR images and additional one nodule that was not detected at routine MR images. Conclusion : 3D MIP image has some limitations but is useful as additional image of routine breast MR Images.

  • PDF

Studies on the Ultrasonographic Images for the Early Pregnancy Diagnosis in Horses (말에서 조기 임신진단을 위한 동음파영상 이용 방법에 관한 연구)

  • 김용준;서세현;김명철;최종복
    • Journal of Veterinary Clinics
    • /
    • v.15 no.1
    • /
    • pp.22-29
    • /
    • 1998
  • To investigate the estrual changes of ovaries, appropriate time of mating, diagnosis of early pregnancy after mating, and diagnosis of twin fetuses, ultrasonography was performed in 61 thorough-bred mares (5-12 years old) which had been raised in Chrju island. The followings are the results obtained: 1. The average size of a follicle of mares was $3.2{\times} 3.8cm$ at the beginning of estrus and $4.2{\times} 3.5 cm$ from the middle of estrus to ovulations respectively, and the average size of a follicle and a corpus luteum was $1.8{\times} 1.4 cm and 3.1{\times}2.3 cm$ in the middle of diestrus, respectively. 2. In the result of pregnancy according to mating time after ultrasonographic examination of follicle size, the mares having a follicle of 4.6-5.0 cm (diameter) were mated on the day of ultrasonographic examination or the next day rind all were conceived (3 mares) and another mares having a follicle of 4.1- 4.5cm (diameter) on the 1st or 2nd day after examination and all were conceived (4 mares). 3. By ultrasonographyi early pregnancy in the mares was diagnosed from 12 days of pregnancy and the equine fetus was directly detectable from 23 days of pregnancy, whereas the heartbeat of a fetus was detectable from 28 days of pregnancy. 4. Diagnosis of earl pregnancy of twin was possible from 16 days of pregnancy. These result indicated that ultrasonography is applicable in mares to diagnose the estrual changes of ovaries and the time of ovulation or mating, and to diagnose early pregnancy from 12 days of pregnancy and early pregnancy of twin fetuses.

  • PDF

Design of a Mapping Framework on Image Correction and Point Cloud Data for Spatial Reconstruction of Digital Twin with an Autonomous Surface Vehicle (무인수상선의 디지털 트윈 공간 재구성을 위한 이미지 보정 및 점군데이터 간의 매핑 프레임워크 설계)

  • Suhyeon Heo;Minju Kang;Jinwoo Choi;Jeonghong Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.3
    • /
    • pp.143-151
    • /
    • 2024
  • In this study, we present a mapping framework for 3D spatial reconstruction of digital twin model using navigation and perception sensors mounted on an Autonomous Surface Vehicle (ASV). For improving the level of realism of digital twin models, 3D spatial information should be reconstructed as a digitalized spatial model and integrated with the components and system models of the ASV. In particular, for the 3D spatial reconstruction, color and 3D point cloud data which acquired from a camera and a LiDAR sensors corresponding to the navigation information at the specific time are required to map without minimizing the noise. To ensure clear and accurate reconstruction of the acquired data in the proposed mapping framework, a image preprocessing was designed to enhance the brightness of low-light images, and a preprocessing for 3D point cloud data was included to filter out unnecessary data. Subsequently, a point matching process between consecutive 3D point cloud data was conducted using the Generalized Iterative Closest Point (G-ICP) approach, and the color information was mapped with the matched 3D point cloud data. The feasibility of the proposed mapping framework was validated through a field data set acquired from field experiments in a inland water environment, and its results were described.

Experimental Study on the Spray Characteristics of Aerated Impinging Jets (기체주입 충돌제트의 분무특성에 관한 실험적 연구)

  • Lee, Keunseok;Yoon, Youngbin;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.24 no.4
    • /
    • pp.185-193
    • /
    • 2019
  • The effervescent atomizer is one of twin-fluid atomizers that aeration gas enters into bulk liquid and two-phase flow is formed in the mixing section. The effervescent atomizer requires low injection pressure and small amount of aeration gas, as compared to other twin-fluid atomizers. In this study, cold flow test was conducted to investigate the spray characteristics of aerated impinging jets. The present effervescent impinging atomizers were composed of the aerator device and like-on-like doublet impinging atomizer which had different impinging angles. To analyze the spray characteristics such as breakup length and droplet size distribution, the image processing technique was adopted by using instantaneous images at each flow condition. Non-dimensional parameters, induced by the homogeneous flow model, were used to predict the breakup length. The breakup length was decreased with the mixture Reynolds number and impinging angle increasing. The result of droplets showed that the size distribution was axisymmetric about the center of the injector and their diameter tended to decrease with increasing GLR.

The observation of microstructures in the trigonal shape memory alloys

  • Liu, Tzu-Cheng;Tsou, Nien-Ti
    • Coupled systems mechanics
    • /
    • v.5 no.4
    • /
    • pp.329-340
    • /
    • 2016
  • The trigonal shape memory alloys (SMAs) have a great potential to be utilized as the applications with special purposes, such as actuators with high operation frequency. Most studies on the trigonal microstructures typically focus on the well-known classic herringbone pattern, but many other patterns are also possible, such as non-classic herringbone, toothbrush and checkerboard patterns. In the current work, a systematic procedure is developed to find all possible laminate twin microstructures by using geometrically linear compatibility theory. The procedure is verified by SEM images with the information of crystallographic axes of unitcells obtained by EBSD, showing good agreement. Many interesting trigonal R-phase patterns are found in the specimen. Then, their incompatibility are analyzed with nonlinear compatibility theory. The relationship between such incompatibility and the likelihood of occurrence of the microstructures is revealed. The current procedure is rapid, computationally efficient and sufficiently general to allow further extension to other crystal systems and materials.

Optimal Conditions for Defect Analysis Using Electron Channeling Contrast Imaging

  • Oh, Jin-Su;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • v.46 no.3
    • /
    • pp.164-166
    • /
    • 2016
  • Electron channeling contrast imaging (ECCI) is a powerful analyzing tool for identifying lattice defects like dislocations and twin boundaries. By using diffraction-based scanning electron microscopy technique, it enables microstructure analysis, which is comparable to that obtained by transmission electron microscopy that is mostly used in defect analysis. In this report, the optimal conditions for investigating crystal defects are suggested. We could obtain the best ECCI images when both acceleration voltage and probe current are high (30 kV and 20 nA). Also, shortening the working distance (6 mm) enhances the quality of defect imaging.