• 제목/요약/키워드: Turns

검색결과 2,181건 처리시간 0.027초

화제 억제제가 첨가된 수용액 액적의 증발냉각 현상 (Evaporation Cooling Phenomena of Droplets Containing Fire Suppression Agents)

  • 유갑종;방창훈;김현우
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.895-903
    • /
    • 2001
  • Evaporation cooling phenomena of droplets containing fire suppression agents on a hot metal surface were experimentally investigated. Solution of water containing potassium acetate (30-50% by weight) and sodium bromide (10-30% by weight) were used in the experiments, and surface temperatures were ranged from 70-116$^{\circ}C$. The evaporation time of the droplet on the heated surface was determined by using frame-by-frame analysis of the video records. It is found that the apparent evaporation time is shorter in turns of pure water, sodium bromide solution and potassium acetate solution. However, the time averaged heat flux is higher in turns of pure water, sodium bromide solution and potassium acetate solution. In-depth temperature variation of the hot metal does not occur significantly by the kinds of additive.

  • PDF

65kW급 HEV용 SRM의 설계 (Design of 65kW Class SRM for HEV)

  • 김태형;안진우;안영주;문재원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.562-564
    • /
    • 2005
  • This paper presents the reasonable design parameters of a SRM for hybrid electric vehicle driving. For the design of SRM, the initial model is designed using the equivalent magnetic circuit method. In order to optimize the SRM for HEV. The initial model is redesigned by FEM with the variation of the stock length and turns of winding. This paper shows that a flat-topped current of a phase can be made from a change of the stack length and the number of turns for high efficiency, high average torque and a lower torque ripple. The change of current falling time as a variation of turn-off angle was shown by FEA. The iron loss and copper loss were described. The torque of the redesigned motor is suitable for low and high speed ranges to drive a HEV that was verified by the speed-torque curve.

  • PDF

쇄교자속비를 이용한 변압기 보호 (Flux Linkages Ratio-Based Transformer Protection)

  • 강용철;이병은;김은숙;원성호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.655-660
    • /
    • 2003
  • This paper describes a transformer protective relaying algorithm based on the ratio of increments of flux linkages (RIFL) of the primary and secondary windings. The algorithm uses integration approximation. The RIFL is equal to the turns ratio for all operating conditions except for an internal fault. For a single-phase transformer and a Y-Y transformer, the increments of flux linkages (IFL) are calculated. For a Y-$\Delta$ transformer, the difference of IFL are calculated to use the line currents rather than the delta winding currents, which are unavailable. Their ratios are compared with the turns ratio. The comparative study between the proposed and conventional differentiation approximation methods was conducted. The test results show that the algorithm reduces the approximation errors of the conventional methods.

100W급 단상직권 정류자 전동기의 최적설계 (Optimal Design of 100W Class Single Phase Series Commutator Motor)

  • 서영택;이우석;공정식;오철수;배상한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.720-722
    • /
    • 2000
  • Single phase series commutator motors is widely used in various home appliances, such as vacuum cleaner, electric mixers, electrical tools, etc. This paper deals with the characteristics of single phase series commutator motors of which parameters varied with stator turns and stack length to find optimal electric and magnetic loading. We try to measure these data through the experiments with several prototype motors. The experimental results show some specific stator turns and stack length with which this motor has the highest efficiency.

  • PDF

변압기를 이용한 저항형 고온초전도 전류제한기의 한류 특성 (Fault Current Limiting Characteristics of Resistive Type SFCL using Transformer)

  • 임성훈;최효상;고석철;이종화;강형곤;한병성
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.288-290
    • /
    • 2003
  • The transformer is expected to be an essential component of resistive type superconducting fault current limiter (SFCL) for both the increase of voltage ratings in SFCL and the simultaneous quench due to different critical current between HTSC elements. However, for the design to prevent the saturation of iron core and the effective fault current limitation, the analysis for operation of SFCL with consideration for the magnetization characteristics are required. In this paper, the fault current limiting characteristics related with the magnetization ones were investigated through the variation of the ratio of the number of turns in the 1st and the 2nd windings. The proper design condition with variation of the number of turns to make the effective fault current limiting operation could be determined.

  • PDF

균열형상변수의 영향 고찰 (A Study on Influences of Crack Morphology Variables)

  • 박원배;이영신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.324-329
    • /
    • 2004
  • In this study, an application of crack morphology variables in the Leak-Before-Break(LBB) evaluation for nuclear piping systems is investigated, including influences on the leakage crack size and crack instability loads. The crack surface roughness and the number of flow turns as a function of the crack opening displacement are applied to LBB evaluations for KSNP pressurizer surge line, for which fatigue and stress corrosion cracking are considered as failure mechanisms. As a result, there would be a significant impact on safety margins to acceptance criteria for the surge line if crack morphology variables are applied additionally to the current regulatory guide without re-analyses for justification of safety factors being applied on the leakage crack size and piping loads for evaluations.

  • PDF

뇌방전에 의한 유도전압의 측정에 대한 기초적 연구 (A Basic Study on the Measurement Induced Voltages due to Lightning Discharges)

  • 이복희;조성철;엄주홍;이우철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.559-564
    • /
    • 2004
  • This paper deals with the device for measuring the time-varying magnetic fields and induced voltages caused by lightning discharges. The two magnetic field measuring systems were designed and made. One consists of the loop-type magnetic field sensor with the active integrator operated by a differential amplifier. The other consists of the loop-type magnetic field sensor and Labview software. The loop-type magnetic field sensor detects the time derivative of the magnetic field being measured, and the signal detected is integrated by the Labview software. As a consequence, from the calibration experiments, the frequency bandwidth of the full measuring system ranges from 400 [Hz] to 1 (MHz) and the response sensitivity are 0.98 (mV/nT) and 22 (mV/nT) for the magnetic field sensor of 2 turns and 6 turns, respectively. Also, the results obtained by the two measuring devices well agreed with each other.

  • PDF

NiZn 페라이트를 내장한 LTCC 인덕터 및 응용 (An LTCC Inductor Embedding NiZn Ferrite and Its Application)

  • 원유준;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권10호
    • /
    • pp.534-539
    • /
    • 2006
  • An integrated inductor using the low-temperature co-fired ceramics(LTCC) technology for low-power electronics was fabricated. In the inductor NiZn ferrite sheet$({\mu}_r=230)$, was embedded to increase inductance. The inductor has Ag spiral coil with 14 turns$(7turns{\times}2layers)$, a dimension of 0.6mm in width, 10um in thickness, and 0.15mm pitch. To evaluate the inductance, including the parasitic resistance, the fabricated inductor was calculated and measured. It was confirmed that calculated values were very close to the measured values. Finally as an application of the LTCC integrated inductor to low power electronic circuits, a LTCC boost DC/DC converter with 1W output power and up to 0.5MHz switching frequency using the inductor fabricated was developed.

발전기 회전자 권선의 층간단락 진단시스템 개발 (Development of Shorted-Turn Diagnosis system for Generator Rotor Winding)

  • 이영준;김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.742-747
    • /
    • 1999
  • On-line diagnosis system has been developed and is now applied the detection of shorted turns in the field winding of large generator. This system consists of data aquisition system and display PC. The data aquisition system detects voltage waveforms from flux probe sensor installed in the stator slot. The display PC shows theshorted-turn situation of generator rotor winding. A shorted-turn diagnosis test wasperformed on five gas turbine generators at the Seoinchon combined cycle power plant. The test was conducted using an new diagnosis system and digital oscilloscope which can identify the pole location, the slot number and the number of shorted turns within each slot. It is confirmed that results of two systems are very same in the field tests.

  • PDF

페라이트 링코어를 이용한 2차원 Fluxgate 센서 (2-Dimensional Fluxgate Sensor using Ferrite Ring Core)

  • 임재환;박한석;안영주;김남호;류지구
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2003년도 하계학술대회 논문집
    • /
    • pp.251-255
    • /
    • 2003
  • In this paper, we have a fluxgate sensor with ferrite core. Thought sensor is consist of one excitation coil and two pick-up coil, and A lock-in amplifier circuity is designed for Signal processing of picking up 2nd harmonics from pick-up coils. Excitation coils is turned by 20 turns, and pick-up coil for picking up harmonics is turned by 40 turns eachother. It convert 2nd harmonics to DC output voltage. Measured output voltage and sensitivity, direction of sensor about out side magnetic field, and also sensor output properties about excitation frequency and current.

  • PDF