• Title/Summary/Keyword: Turn-to-turn

Search Result 6,307, Processing Time 0.029 seconds

Design of Switched Reluctance Motor for Minimizing the Torque Ripple (스위치드 릴럭턴스 전동기의 토오크 리플 저감 설계)

  • Kim, Youn-Hyun;Choi, Jae-Hak;Kim, Sol;Lee, Ju;RhYu, Se-Hyun;Sung, Ha-Kyung;Im, Tae-Bin;Borm, Jin-hwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.339-350
    • /
    • 2002
  • Pole arcs, turn-on angle, and turn-off angle are major design factors, which affects Switched Reluctance Motor's torque performance. If these design factors are considered independently, the enhancement of SRM performance is restricted. Therefore, we need to consider pole arcs, turn-on angle and turn-off angle at the same time, when we design SR. In this paper, we analyze how these factors affect to torque ripple and average torque by using dynamic Finite Element Method(FEM) with derive circuit and present the good design results according to the various speeds. Especially, we formulate turn-on and turn-off angle from a voltage equation and present effective design range.

Establishing Probability-Based Warrants for Right-Turn Lanes at Unsignalized Intersections (확률기반 비신호교차로의 우회전 전용차로 설치 기준 정립)

  • Moon, Jaepil
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.183-190
    • /
    • 2017
  • PURPOSES : The objective of this study is to establish the traffic volume-based warrants of right-turn lanes at unsignalized intersections and to introduce a risk probability methodology based on the warrants. METHODS : In this study, a risk probability of a potential rear-end collision is applied between a right-turn vehicle and the immediately following through vehicle. Using the shifted negative exponential model and the compound probability theorem, the risk probability can be expressed as the function of directional volumes and the percentage of right-turns for a two-lane and four-lane highway, respectively. RESULTS : Based on the risk probablity, guidelines for installing right-turn lanes on two-lane and four-lane highways were developed. The risk probability also showed rationality by comparing with right-turn same-direction conflicts observed in-situ. CONCLUSIONS : The results of our study define the total approaching volumes to encourage a right-turn lane as a function of operating speed, percentage of right-turn, and number of lanes.

Dielectric Characteristics of Turn-ro-Turn Insulation for SFCL (초전도 한류기의 턴간 절연특성)

  • Baek, Seung-Myeong;Joung, Jong-Man;Lee, Chang-Hwa;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • Interconnected power system operation has given rise to the problem of increased fault levels and leads to over stressing of all the components. Use have been made of recently developed high Tc superconductor in devising a superconducting fault current limiter (SFCL) that promises optimum performance in terms of capital cost, size, auto sensing, operational losses, response time and reliability. Recently, research about the application of the SFCL is actively progressing in Korea. To be applied for SFCL practically, the electrical insulation design of SFCL must be developed. Therefore, this paper presents the result of an investigation of the dielectric characteristics of turn-to-turn insulation for SFCL in liquid nitrogen. The dielectric characteristics of turn-to-turn insulation models of SFCL were investigated. We obtained following results. The breakdown voltages increased as the spacer thickness and length increased. And the breakdown voltages of turn-to-turn model without spacer were higher than the breakdown voltages of turn-to-turn model with spacer under impulse as well as AC voltages. The information gathered in this test series should be helpful in the design of liquid nitrogen filled SFCL.

  • PDF

A Study on Installation of U-Turn Lane for Efficient Operation of Left Turn at Signalized Intersections (신호교차로 좌회전 효율적 처리를 위한 유턴차로 설치방법 연구)

  • Park, Chahgwha;Yoon, Byoungjo;Kang, Bongsuk
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.597-606
    • /
    • 2015
  • Until now, u-turn lane installation methods have been studied variously. But, There is no specific standard yet. This study ranges are commercial area in Incheon metropolitan city through field investigation and presents specific design standard for efficient operation of left turn using a field data through calculating relevant permitted u-turn lane length and minimum separation distance from the front intersection to starting point of permitted u-turn lane in urban signalized intersections in commercial area. Relevant permitted u-turn lane length is found to be 32m and minimum separation distances from the front intersection to starting point of permitted u-turn lanes are 72m, 40m, 24m in case of 1 left turn lane, 2 left turn lanes and 3 left turn lanes respectively. By comparing result values and field data, they had a large difference under the similar situations in their lengths. This result is caused of no specific standard about design of u-turn lanes. If results of this study applied to design of u-turn lanes, signalized intersections in urban commercial areas would be operated more safety and efficiently.

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

The Dielectric Characteristics of Turn-to-Turn Insulation for DC Reactor Type HTSFCL (DC reactor type 고온호전도 한류기의 턴간 절연 특성)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1299-1304
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

Comparison of turn-on/turn-off transient in Electron Irradiated and Proton Irradiated Silicon pn diode (전자와 양성자를 조사한 PN 다이오드의 turn-on/turn-off transient 특성 비교)

  • Lee, Ho-Sung;Lee, Jun-Ho;Park, Jun;Jo, Jung-Yol
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1947-1949
    • /
    • 1999
  • Carrier lifetime in silicon power devices caused switching delay and excessive power loss at high frequency switching. We studied transient turn-on/turn-off transient characteristics of electron irradiated and proton irradiated silicon pn junction diodes. Both the electron and proton irradiation of power devices have already become a widely used practice to reduce minority carrier lifetime locally[1]. The sample is n+p junction diode, made by ion implantation on a $20\Omega.cm$ p-type wafer. We investigated turn-on/turn-off transient & breakdown voltage characteristics by digital oscilloscope. Our data show that proton irradiated samples show better performance than electron irradiated samples.

  • PDF

Estimation of the Through Car Equivalent for Left-Turn Movement According to the Left-Turn Curve Radius in the Signalized Intersection (신호교차로에서 곡선반경에 따른 좌회전의 직진환산계수 산정)

  • 오영태;김기형
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.2
    • /
    • pp.21-28
    • /
    • 2001
  • This study is to estimate the through car equivalent for left-turn movement according to left turn radius in the signalized intersection. The saturation flow rate for left-turn movement in 92' KHCM(Korea Highway Capacity Manual) is the same as that for through movement in the signalized intersection where the left turn radius is over 20m. This study uses Duncan 'Test's Test in order to find out the saturated position for queued vehicle in the signalized intersection. It found that the saturated flow rate of left-turn movement in the signalized intersection is less than that of through movement where the left-turn radius is less than 20m. It found that the through car equivalents for left-turn movement according to left-turn radius(8m-20m) are between 1.05 and 1.14.

  • PDF

The Impact of Parasitic Elements on Spurious Turn-On in Phase-Shifted Full-Bridge Converters

  • Wang, Qing
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.883-893
    • /
    • 2016
  • This paper presents a comprehensive analysis of the spurious turn-on phenomena in phase-shifted full-bridge (PSFB) converters. The conventional analysis of the spurious turn-on phenomenon does not establish in the PSFB converter as realizing zero voltage switching (ZVS). Firstly, a circuit model is proposed taking into account the parasitic capacitors and inductors of the transistors, as well as the parasitic elements of the power circuit loop. Second, an exhaustive investigation into the impact of all these parasitic elements on the spurious turn-on is conducted. It has been found that the spurious turn-on phenomenon is mainly attributed to the parasitic inductors of the power circuit loop, while the parasitic inductors of the transistors have a weak impact on this phenomenon. In addition, the operation principle of the PSFB converter makes the leading and lagging legs have distinguished differences with respect to the spurious turn-on problems. Design guidelines are given based on the theoretical analysis. Finally, detailed simulation and experimental results obtained with a 1.5 kW PSFB converter are given to validate proposed analysis.

A Study on the Operational Method of Urban Arterial With U-Turn (U-Turn을 이용한 간선도로 운영방안)

  • 박용진;손한철
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.1
    • /
    • pp.17-26
    • /
    • 2000
  • U-turns are allowed widely at the intersections by local police department while the left-turn Phases have been gradually Prohibited. However, any strategies for U-turn movements at signalized intersections are unavailable. Therefore, the Purpose of this study is to Propose the efficient operational method of Urban arterial adopting U-turn strategies. Four alternatives are evaluated they are, 1) U-turn movements are allowed at the adjacent intersection with exclusive U-turn lane while the major or the minor approach is Prohibited, 2) U-turn movements are allowed at the adjacent mid-block Pedestrian crossing with exclusive U-turn lane while the major approach is Prohibited. 3) U-turn movements are allowed at the adjacent mid-block Pedestrian crossing with exclusive U-turn lane while the minor approach is prohibited and 4) Comparative one between alternative 3 and 4. From the results of this study, it concludes that the method of U-turn movements allowed at the adjacent mid-block pedestrian crossing with exclusive U-turn lane is the most effective strategy among those alternatives. The strategies of alternative 1 and 4 are Proposed by the boundary based on the major through and left-turn volumes and the minor left-turn volume.

  • PDF