• 제목/요약/키워드: Turn-off losses

검색결과 91건 처리시간 0.039초

Comparison of PWM Strategies for Three-Phase Current-fed DC/DC Converters

  • Cha, Han-Ju;Choi, Soon-Ho;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.363-370
    • /
    • 2008
  • In this paper, three kinds of PWM strategies for a three-phase current-fed dc/dc converter are proposed and compared in terms of losses and voltage transfer ratio. Each PWM strategy is described graphically and their switching losses are analyzed. With the proposed PWM C strategy, one turn-off switching of each bridge switch is eliminated to reduce switching losses under the same switching frequency. In addition, RMS current through the bridge switches is lowered by using parallel connection between two bridge switches and thus, conduction losses of the switches are reduced. Further, copper losses of the transformer are decreased due to the reduced RMS current of each transformer's winding. Therefore, total losses are minimized and the efficiency of the converter is improved by using the proposed PWM C strategy. Digital signal processor (DSP: TI320LF2407) and a field-programmable gate array (FPGA: EPM7128) board are used to generate PWM patterns for three-phase bridge and clamp MOSFETs. A 500W prototype converter is built and its experimental results verify the validity of the proposed PWM strategies.

An Improved Zero Voltage Switching Forward DC/DC Converter For Reducing Switching Losses

  • Kim, Eun-Soo;Joe, Kee-Yeon;Park, Hae-Young;Kim, Yoon-Ho;Kim, Choon-Same
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1051-1055
    • /
    • 1998
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.

소프트 스윗치를 이용한 불연속 모드 3상 AC-DC 부스터 컨버터에 관한 연구 (A study on Three-Phase AC-DC Boost Converter using A Soft-Switching for discontinuous Mode)

  • 전중함;곽동걸;김천식;서기영;권순걸;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.188-190
    • /
    • 1995
  • This paper describes a soft switching using discontinuous inductor current. The soft switching snubber circuit provides ZCS and ZVS for main switch. For high power applications, the input ractifier is fed from a three-phase ac source. The Conventional switching method is hard switching technics, because of the device turn off is ocurred in maximum reactor current. In this time, switching losses are maximised by the hard switching. In generally, soft switching technique has been adjusted with the snubber condenser in order to compensates for this losses. So, it was compared hard switching with soft switching which has proposed in this paper for switching losses, distortion factor by the simulation.

  • PDF

A New High Frequency Linked Soft-Switching PWM DC-DC Converter with High and Low Side DC Rail Active Edge Resonant Snubbers for High Performance Arc Welder

  • Kang, Ju-Sung;Fathy, Khairy;Hong, Doo-Sung;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.281-283
    • /
    • 2006
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. The effectiveness of these new DC-DC converters topologies is proved for low voltage and large current high efficiency DC-DC power supplies as TIG arc welding machine from a practical point of view.

  • PDF

A Novel Soft-Switching PWM DC/DC Converter with DC Rail Series Switch-Parallel Capacitor Edge Resonant Snubber Assisted by High-Frequency Transformer Parasitic Components

  • ;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.377-382
    • /
    • 2005
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. One topology of proposed DC-DC converters is composed of a typical voltage source-fed full-bridge high frequency PWM inverter using DC busline side series power semiconductor switching devices with the aid of a parallel capacitive lossless snubber. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. It is proved that the more the switching frequency of full-bridge soft switching inverter increases, the more soft-switching PWM DC-DC converter with a hish frequency transformer link has remarkable advantages for its efficiency and power density as compared with the conventional hard-switching PWM inverter type DC-DC converter

  • PDF

변압기의 가변 턴비 기법을 통해 넓은 전압범위를 만족하는 리튬이온 배터리용 고효율 LLC 공진형 컨버터 (A High Efficiency LLC Resonant Converter with Wide Operation Range using Adaptive Turn Ratio Transformer for a Li-ion Battery)

  • 한형구;최영준;김래영;김주용;조진태
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.305-311
    • /
    • 2017
  • In this paper, the LLC resonant converter battery charger, using adaptive turn ratio scheme, is proposed to achieve high efficiency and wide range output voltage. The LLC converter high frequency transformer has an adaptively changed turn ratio by the auxiliary control circuitry. As a result, the optimal converter design with a large magnetizing inductance is easily achieved to minimize the conduction and the turn-off losses while providing widely regulated voltage gain capability to properly charge the Li-ion battery. The proposed converter operational principle and the optimal design considerations are illustrated in detail. Finally, several simulation results verify the proposed LLC resonant converter's effectiveness.

A High Efficiency LLC Resonant Converter-based Li-ion Battery Charger with Adaptive Turn Ratio Variable Scheme

  • Choi, Yeong-Jun;Han, Hyeong-Gu;Choi, See-Young;Kim, Sang-Il;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.124-132
    • /
    • 2018
  • This paper proposes an LLC resonant converter based battery charger which utilizes an adaptive turn ratio scheme to achieve a wide output voltage range and high efficiency. The high frequency transformer of the LLC converter of the proposed strategy has an adaptively changed turn ratio through the auxiliary control circuit. As a result, an optimized converter design with high magnetizing inductance is possible, while minimizing conduction and turn-off losses and providing a regulated voltage gain to properly charge the lithium ion battery. For a step-by-step explanation, operational principle and optimal design considerations of the proposed converter are illustrated in detail. Finally, the effectiveness of the proposed strategy is verified through various experimental results and efficiency analysis based on prototype 300W Li-ion battery charger and battery pack.

온도 변화에 따른 NPT-IGBT의 과도 특성 (Transient Characteristics of NPT-IGBT with different temperatures)

  • 류세환;황광철;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 2002
  • In this work, transient characteristics of NPT(Non Punch Through)-IGBT(Insulated Gate Bipolar Transistor) have been studied with different temperatures analytically. Power losses are caused by heat generated in MIT-IGBT for steady state and transient state conditions. We therefore have focused on the analysis of excess carrier concentration and excess charge injected into N-drift layer with different temperatures and have obtained anode voltage drop during turn-off with lifetime of 2.4[${\mu}$s].

  • PDF

RCD Snubber Design and Analysis using Resonance Coordinate

  • Li, Shan-Mei;Koo, Gwan-Bon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.347-348
    • /
    • 2012
  • An approach to design and analyze an RCD snubber for flyback converters will be introduced. The resonance coordinate provides an easy way to understand the transient period of the switch turn-off and helps to design and analyze the RCD snubber easily. An example of analyzing RCD snubber losses for 40W prototype will be given and experimented to show the effectiveness of the suggested method.

  • PDF

부스트 컨버터용 새로운 에너지 재생 스너버 (A New Energy Recovery Snubber for Boost Converter)

  • 김만고
    • 전력전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.57-63
    • /
    • 1997
  • 고속 스위칭으로 동작하는 부스트 컨버터의 주 스위치자 ON/OFF 할 때, 주 스위치에 큰 전류나 전압이 가해질 수 있어서 스위칭 소자 파손을 초래할 수 있다. 이 스위칭 스트레스를 감소시키는 수단으로 스너버가 주로 이용된다. 최근에 스너버 에너지를 재생시켜 전력 컨버터의 에너지 효율을 향상시키는 방법들이 활발히 연구되고 있으나, 부가적인 제어가 필요없고 성능이 우수한 수동스너버에 대한 연구는 미진한 편이다. 본 연구에서는 부가적인 제어가 필요없고 에너지 재생이 가능한 수동 스너버를 가진 부스트 컨버터를 제안한다. 제안된 스너버를 갖는 부스트 컨버터의 제어는 종래의 제어방법과 동일하다. 또한 주 스위치의 전류 및 전압 스트레스를 감소시키면서 스너버 에너지를 출력으로 전달하는 에너지 재생 스너버의 구현은 몇 개의 소동 소자를 부가하여 구현된다. 제안된 회로에 대한 분석이 수행되고, 시뮬레이션 및 실험을 통해 유용성을 검증한다.

  • PDF