• Title/Summary/Keyword: Turn-off loss

Search Result 127, Processing Time 0.033 seconds

Magnetic Coupled ZVT PWM Boost PFC Pre-regulator (에너지 회생 변압기를 사용한 영전압 과도상태(ZVT) 부스트 역률보상 회로)

  • Yang Joon-Hyun;Lee Dong-Young;Cho Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.548-551
    • /
    • 2001
  • A zero-voltage transition (ZVT) PWM boost PFC converter using a transformer to recover the resonant energy into the input voltage is proposed. The proposed converter reduces turn-off switching loss of the auxiliary switch. The resonant current of the auxiliary circuit is optimally reduced by the feed-forwarded input voltage. Moreover, the resonant energy of the auxiliary circuit is recovered into the load and input voltages. In this paper, the modes of converter operation are explained and analyzed, design guidelines are given, and experimental results of 1.2kW, 200kHz prototype system are presented.

  • PDF

High Efficiency DC/DC converter using MOSFET and IGBT (MOSFET와 IGBT를 이용한 DC/DC 컨버터의 효율 증대)

  • Kwon H.N.;Jeon Y.S.;Ban H.S.;Choe G.H.;Bae J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.520-524
    • /
    • 2001
  • Recently, the demand of large capacity SMPS for industrial area is increasing. Full-bridge dc-dc converter with IGBT is most widely used for large capacity SMPS because IGBT has a low-conduction loss and large current capacity, But most large capacity Full-bridge do-dc converter using IGBT has low operating frequency because of switching loss at IGBT especially at turn-off by current tail and it's cause of relatively big converter size. MOSFET has low switching losses has been widely used for high frequency SMPS but it has a problem to apply to large capacity SMPS because it has large conduction resistance causing large on-time losses. In this paper, for reduction losses at switching device, MOSFET is applied at parallel with IGBT in full-bridge dc/dc converter.

  • PDF

The Sugge Voltage restraint of induction motor using low-loss snubber circuit (저손실 스너버 회로를 이용한 유도전동기의 서지전압 억제)

  • Cho, Man-Chul;Mun, Sang-Pil;Kim, Chil-Yong;Kim, Ju-Yong;Shu, Ki-Young;Kwon, Soon-Kurl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.473-477
    • /
    • 2007
  • The development of advanced Insulated Gate Bipolar Transistor(IGBT)has enabled high-frequency switching operation and has improved the performance of PWM inverters for motor drive. However, the high rate of dv/dt of IGBT has adverse effects on motor insulation stress. In many motor drive applications, the inverter and motor are separated and it requires long motor feds. The long cable contributes high frequency ringing at the motor terminal and it results in hight surge voltage which stresses the motor insulation. The inverter output filter and RDC snubber are conventional method which can reduce the surge voltage. In this paper, we propose the new low loss snubber to reduce the motor terminal surge voltage. The snubber consists of the series connection of charging/discharging capacitor and the voltage-clamped capacitor. At IGBT turn-off, the snubber starts to operate when the IGBT voltage reaches the voltage-clamped level. Since dv/dt is decreased by snubber operating, the peak level of the surge voltage can be reduced. Also the snubber operates at the IGBT voltage above the voltage-clamped level, the snubber loss is largely reduced comparing with RDC snubber. The proposed snubber enables to reduce the motor terminal surge voltage with low loss.

  • PDF

PWM-PFC Step-Up Converter For Novel Loss-Less Snubber (새로운 무손실 스너버에 의한 PWM-PFC 스텝-업 컨버터)

  • Kwak Dong-Kurl;Lee Bong-Seob;Jung Do-Young
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.1 s.307
    • /
    • pp.45-52
    • /
    • 2006
  • In this paper, authors propose a step-up converter of pulse width modulation (PWM) and power factor correction (PFC) by using a novel loss-less snubber. The proposed converter for a discontinuous conduction mode (DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Thereupon, the input power factor is nearly unity and the control method is simple. In the general DCM converters, the switching devices are fumed-on with the zero current switching (ZCS), and the switching devices must be switched-off at a maximum reactor current. To achieve a soft switching (ZCS and ZVS) of the switching turn-off, the proposed converter is constructed by using a new loss-less snubber which is operated with a partial resonant circuit. The result is that the switching loss is very low and the efficiency of converter is high. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.49-57
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flybark converter by adding two method PFC (Power Factor Correction) circuit-two-stage and single-stage. The addition of active clamp circuit also provide a mechanism fur achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier switching loss and switching noise, due to diode reverse recovery. As a results, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converters improve the input PF of 300[W] ZVS flyback converter by adding single-stage two-stage PFC circuit.

  • PDF

A Single-Stage AC/DC Converter with Low Voltage Stresses and Reduced Switching Losses

  • Kim, Kyu-Tae;Choi, Woo-Young;Kwon, Jung-Min;Kwon, Bong-Hwan
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.823-834
    • /
    • 2009
  • This paper proposes a high-efficiency single-stage ac/dc converter. The proposed converter features low voltage stresses and reduced switching losses. It operates at the boundary of discontinuous- and continuous-conduction modes by employing variable switching frequency control. The turn-on switching loss of the switch can be reduced by turning it on when the voltage across it is at a minimum. The voltage across the bulk capacitor is independent of the output loads and maintained within the practical range for the universal line input, so the problem of high voltage stress across the bulk capacitor is alleviated. Moreover, the voltage stress of the output diodes is clamped to the output voltage, and the output diodes are turned off at zero-current. Thus, the reverse-recovery related losses of the output diodes are eliminated. The operational principles and circuit analysis are presented. A prototype circuit was built and tested for a 150 W (50V/3A) output power. The experimental results verify the performance of the proposed converter.

A Study on the ZVS-SEPP Type High Frequency Resonant Inverter with induction Heating Jar(I) (IH-Jar용 ZVS-SEPP 고주파 공진 인버터에 관한 연구(I))

  • Kim, Jong-Hae;Kim, Dong-Hee;No, Chae-Gyan;Bae, Young-Ho;Baek, Seung-Myun;Moon, Chang-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.2
    • /
    • pp.69-74
    • /
    • 1999
  • This paper presents about a example of circuit design and characteristics of proposed circuit in the case of adopted the high frequency resonant Inverter of SEPP type using ZVS(Zero-Voltage-Switching) to the Induction heating load. The soft switching technology known as ZVS is used to reduce turn on and off loss at switching. Also, this paper realizes quantitative circuit analysis which has change the equivalent of Induction heating load to the electric circuit. According to the calculated characteristics value, a method of the circuit designs and operation characteristics of the Inverter is proposed. In addition, this paper proves the propriety of theoretical analysis through the experiment. The proposed inverter shows it can be practically used as power source system for induction heating Jar etc.

  • PDF

A High Efficiency MHD Lamp Ballast with a Frequency Controlled Synchronous Rectifier (주파수 가변 동기 정류기를 이용한 고효율 MHD 램프 안정기)

  • Hyun B.C.;Lee I.K.;Cho B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.71-75
    • /
    • 2004
  • In this paper, in order to develop a simple and high efficient ballast without an external igniter, a half-bridge type ballast with a coupled inductor and a frequency controlled synchronous rectifier is proposed. The internal LC resonance of the buck converter is used In generate a high voltage pulse for the ignition, and the coupled inductor filter is used for steady state ripple cancellation. Also, a synchronous buck converter is applied for the DC/DC converter stage. In order to improve the efficiency of the ballast, a frequency control method is proposed. This scheme reduces a circulation current and turn off loss of the MOSFET switch on the constant power operation, which results in increase of the efficiency of the ballast system about $4\%$, compared to a fixed frequency control. It consists a 2-stage version ballast with a PFC circuit. The results are verified with hardware experiments.

  • PDF

The Recommendation on Power Saving through the Measuring of the Standby Power of OA Equipments (OA기기의 대기전력 측정을 통한 절전 평가 제안)

  • Kim, Man-Geon;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.161-167
    • /
    • 2013
  • The purpose of this study was to assess power loss in the computer and office automation equipment and identified a way to save power consumptions through field measurement. In this study, the meaning of standby power was to consume power while waiting for the use of any electronic equipment. This standby consumption was about 11% of total power consumption even though we did not seriously realize it. Therefore, it was very important to measure accurate power consumption at the standby status of electronic equipment. In addition, it also helped to reduce potential risks of electricity associated disasters. This study proposed the way to reduce power losses through automatic turn off switches for power outlets and switches. Finally, this study can evaluate power consumption patterns that can reduce power consumptions and potential risks of power related disasters. This also can achieve the goals of sustainability that can reduce environmental impacts by lowering energy consumptions and greenhouse gas emissions.

A Characteristic Analysis of Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and ZVS function (LCCC 공진회로와 ZVS 기능을 동시에 갖는 전류형 Push Pull DC-DC 컨버터의 특성해석)

  • An, Hang-Mock;Hwang, Gye-Ho;Lee, Dal-Hae;Nam, Seung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1324-1326
    • /
    • 2000
  • This paper proposes a Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and Zero Voltage Switching function to reduce turn on and off loss at the switching instants. This paper have the advantage which is able to operating safely in load short, because of DC reactor is connected with resonance reactor in order to supply a fixed current with low ripple from DC Power supply. The capacitor ($C_1$, $C_2$) connected in switch are common using as resonance capacitor and ZVS capacitor. The analysis of the proposed Current-Fed Push Pull type DC-DC converter is generally described by using normalized parameter, and we have evaluated characteristic values which is needed to design a circuit. We confirm a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment using MOSFET as switching devices.

  • PDF