Active Vibration Measuring Sensor for Nondestructive Test of Electric Power Transmission Line Insulators (송전선로 애자의 비파괴 검사를 위한 능동형 진동 측정센서)

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.424-430
    • /
    • 2008
  • A new active vibration measurement system in electric power transmission line is presented, using in the nondestructive test. With a permanent magnet and a couple of coils, the system exerts impact force to a test object and in turn picks up the vibration of the object. The natural frequency with the amplitude obtained from the system are used as a basis for the detection of defects in the object. The system is controlled by an electronic device designed to facilitate the fully automated testing process with consistent repeatability and reliability which are essential to the nondestructive test. The system is expected to be applied to the wide area of defect detection including the classification of mechanical parts in production and inspection processes.

ROM(Reducing Opposed Multilobed) Flap Repair for the Treatment of Medium Sized Skin Lesion (ROM(Reducing Opposed Multilobed) 피판을 이용한 중간 크기 피부병변의 치험례)

  • Cho, Jong Je;Hong, Yoon Gi;Seo, Sang Won;Chang, Choong Hyun
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.748-752
    • /
    • 2006
  • Purpose:Circular skin lesions between 10 and 35 mm in diameter generate problems often. Direct closure of the lesion risks excessive wound tension or wound dehiscence. Skin grafts heal slowly and often remain unsightly. Traditional skin flaps have a limited role. We treated this circular medium-sized skin lesion(10 - 35 mm sized) by reducing opposed multilobed(ROM) flap. Methods: ROM flap involves a series of semicircular lobes extending both cephalic and caudal from the defect. Direction of the semicircular multilobed flap is set parallel to relaxed skin tension line(RSTL) to minimize scar formation. First semicircle is drawn 60% in diameter of the defect. Second semicircles are drawn at the cephalic and caudal aspects of the original semicircles. These semicircles are 60% in diameter of the first semicircle. Additional semicircles are repeatedly drawn until the tension of skin flaps becomes free. ROM flap has a length-to-base ratio of 0.5 resulting in lower theoretical risk of end flap necrosis than a random pattern flap with a large ratio. The technique involves lobes most distant from the primary defect being transposed in turn closer to the defect. Results: The ROM flap reduces skin tension concerns, lowers the risk of flap necrosis and allows for quicker and more aesthetic healing. Results were generally good and major complications, such as dehiscence, infection, or delayed healing, did not occur. Conclusion: ROM flap repair allows the plastic surgeon an additional option when faced with a circular medium-sized skin lesion.

Static and Dynamic Characteristics of PT-IGBT by Proton Irradiation (양성자 주입 조건에 따른 PT-IGBT의 정특성 및 동특성 분석)

  • Choi, Sung-Hwan;Lee, Yong-Hyun;Bae, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.14-15
    • /
    • 2007
  • Proton irradiation technology was used for improvement of switching characteristics of the PT-IGBT. The proton irradiation was carried out at 5.56 MeV energy from the back side of processed wafers and at 2.39 MeV energy from the front side of the wafers. The on-state and off-state I-V characteristics and switching properties of the device were analyzed and compared with those of un-irradiated device and e-beam irradiated device which was conventional method for minority carrier lifetime reduction. The proton irradiated device by 5.56 MeV energy was superior to e-beam irradiated device for the on-state and off-state I-V characteristics, nevertheless turn-off time of proton irradiated device was superior to that of the e-beam irradiated device.

  • PDF

Quasi-resonant Two-Inductor boost converter for PV-MIC (두 개의 인덕터를 갖는 PV-MIC용 준공진 부스트 컨버터)

  • Park, Seung-Won;Kim, Jae-Hyung;Kim, Jun-Gu;Ryu, Dong-Kyun;Kim, Tae-Hoon;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.188-189
    • /
    • 2010
  • This paper proposed a new zero-voltage switching(ZVS) Two-Inductor boost converter. The conventional Two-Inductor boost converter has defect. When the switch is turned off, the high voltage spike is occurred in the switch by leakage inductance and switch parasitic capacitor. To solve this problem, the parallel resonant capacitor is added to the conventional Two-Inductor boost converter. Using quasi-resonant between parallel resonant capacitance and leakage inductance, the switches is operated soft switching. A reduction of transformer turn ratio is achieved by the voltage doubler rectifier.

  • PDF

A CASE REPORT OF IMPLANT PLACEMENT IN DISTRACTION-AUGMENTED ALVEOLAR BONE OF THE MANDIBLE (하악골 결손부의 치조골 신장술을 이용한 임플란트 식립 증례보고)

  • Ryu, Hyun-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.4
    • /
    • pp.325-329
    • /
    • 2009
  • Objective : This is to report the effectiveness of intraoral distraction osteogenesis, iliac bone graft for alveolar augmentation in the extremely atrophied alveolar defects after infected allobone grafted area. Subjects and Methods : Anterior segmental osteotomy was performed and the trans-oral alveolar distractors (Martin, Germany) were applied in patient with the severe acquired anterior mandibular and mandibular defect after ameloblastoma enucleation. Iliac bone grafts were performed in defect sites and distraction osteogenesis were treated. After latent period for 1 week, the osteomized alveolar segments were distracted by 0.75 mm a day (0.25 mm/1 turn) for 10 days The consolidation period was about 12 weeks. Thereafter, 2 titanium threaded implants were simultaneously installed with removal of distractor. For oral rehabilitiation, The implants were installed in maxilla, mandible. It was tested with clinically and radiographically. Results : Amounts of acquired alveolar bone were 10 mm with the increased width of the ridge crests and soft tissue expansion. Dental implants installated on the augmented alveolar ridges in 12 weeks after distraction were confirmed as in good osseointegration and in good function without any complications. Conclusion : Intraoral distraction osteogenesis can be a good option for alveolar ridge augmentation of the severely atrophied ridges and soft-tissue defects.

Three-dimensional bio-printing and bone tissue engineering: technical innovations and potential applications in maxillofacial reconstructive surgery

  • Salah, Muhja;Tayebi, Lobat;Moharamzadeh, Keyvan;Naini, Farhad B.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.18.1-18.9
    • /
    • 2020
  • Background: Bone grafting has been considered the gold standard for hard tissue reconstructive surgery and is widely used for large mandibular defect reconstruction. However, the midface encompasses delicate structures that are surrounded by a complex bone architecture, which makes bone grafting using traditional methods very challenging. Three-dimensional (3D) bioprinting is a developing technology that is derived from the evolution of additive manufacturing. It enables precise development of a scaffold from different available biomaterials that mimic the shape, size, and dimension of a defect without relying only on the surgeon's skills and capabilities, and subsequently, may enhance surgical outcomes and, in turn, patient satisfaction and quality of life. Review: This review summarizes different biomaterial classes that can be used in 3D bioprinters as bioinks to fabricate bone scaffolds, including polymers, bioceramics, and composites. It also describes the advantages and limitations of the three currently used 3D bioprinting technologies: inkjet bioprinting, micro-extrusion, and laserassisted bioprinting. Conclusions: Although 3D bioprinting technology is still in its infancy and requires further development and optimization both in biomaterials and techniques, it offers great promise and potential for facial reconstruction with improved outcome.

Surgical Outcome of Reconstruction of Neglected Chronic Achilles Tendon Ruptures (진구성 만성 아킬레스 건 파열의 수술적 치료의 결과)

  • Sung, Ki-Sun;Heo, Jae-Won
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • Purpose: The purpose of this study was to report the surgical outcome of reconstruction of neglected chronic Achilles tendon ruptures with various methods including Achilles tendon allograft. Materials and Methods: Between October 2003 and November 2008, 8 consecutive neglected chronic Achilles tendon ruptures with the defect gap of more than 4 cm underwent surgical reconstruction including V-Y advancement, gastrocnemius fascial turn-down flap, flexor hallucis longus transfer and Achilles tendon allograft. There were 7 males and 1 female who were evaluated at more than 18 months after surgery. At the time of followup, all patients were assessed with regard to postoperative complications, their self-reported level of satisfaction, the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot scale, 10 repetitive single heel rise, single leg hopping test, and ankle range of motion. Results: The AOFAS score increased from average 71.4 (50-87) to 96.4 (86-100). All patients were able to perform 10-repetitive single heel raise and single leg hopping at the latest follow up. No patient experienced wound complications and deep infection. Six patients were rated as 'excellent' and the other two as 'good'. Conclusion: Neglected chronic Achilles tendon ruptures could be successfully treated with careful selection of the reconstruction method according to the amount of defect gap. With an extensive defect, Achilles tendon allograft can be a good option when the reconstruction is not feasible otherwise.

Superficial Circumflex Iliac Artery Perforator Free Flap for Reconstruction of Small or Medium Sized Defect on Lower Extremities (하지의 작거나 중등도의 결손 부위 재건을 위한 얕은엉덩휘돌이동맥 천공지 유리 피판술)

  • Kim, Kyu Nam;Jeong, Woo Shik;Hong, Joon Pio;Yoon, Chi Seon
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.1
    • /
    • pp.18-23
    • /
    • 2013
  • Purpose: For reconstruction of lower extremity defects, various flaps can be used and the appropriate flap must be selected and applied according to the size of the defect. In particular, in cases where the defect size is small to moderate, thinner or smaller volume flaps are useful. The authors performed reconstruction of small to moderate defects on the lower extremities using superficial circumflex iliac artery perforator free flaps and are reporting the results. Materials and Methods: Fifteen patients underwent reconstruction of defects on lower extremity areas using superficial circumflex iliac artery perforator free flaps from July 2011 to July 2012 at this hospital. The flaps were elevated from above the deep fat layer, and, in all cases, the vessel diameter of the flaps was less than 1mm, with the exception of superficial vein that accompanied it. Results: The mean follow up period was 4.46 months, and, despite a partial loss in the flap in two cases, there were no total losses. All donor sites were closed with primary closure, and there was no occurrence of complications, such as hematomas, seromas, or lymphorrheas. The patients were highly satisfied with the donor site scar since it could be masked by underwear. Conclusion: Compared to other flaps, superficial circumflex iliac artery perforator free flaps are thinner in thickness and smaller in volume, which results in a more natural contour of the recipient site after the operation. In addition, since the flap can be elevated from supra-deep fat layer, the operation time can be shortened, and lymphorrhea can be prevented, which in turn lessens donor-site morbidity.

  • PDF

Surface Segregation of Sulfur in Ti and ti-Aluminide Alloys (티타늄과 티타늄 알루니마이드 합금에서 황의 표면석출)

  • 이원식;이재희
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.1
    • /
    • pp.39-47
    • /
    • 1996
  • The segregation of S in electrotransport-purified polycrystaline $\alpha$-Ti and Ti-aluminide alloys has been studied by Auger electron spectroscopy(AES), Ion scattering spectroscopy(ISS) and Secondary ion mass spectrometry(SIMS) in the temperature range extending from 20 to $1000^{\circ}C$. The chemisorbed oxygen and carbon on Ti were observed to disappear at T>$400^{\circ}C$ after which the S signal increased to levels approaching 0.5 monolayer. At lower temperatures the presence of the surface oxygen and carbon appeared to inhibit the segregation, presumably because there were no available surfaces sites for the S emerging from the bulk. The activation energy for the S segregation in pure polycrystaline Ti was determined to be 16.7 kcal/mol, which, when compared to S segretation from single-crystal Ti, is quite small and suggests grain boundary or defect diffusion segregation kinetics. In the Ti-aluminide alloys, the presence of Al appeared to enhance the retention of surface oxygen which, in turn, substantially reduced the S segretation. The $\gamma$ alloy, with its high Al content, exhibited the greatest retention of surface oxygen and the smallest quantity of the S segregation(T$\simeq1000^{\circ}C$).

  • PDF

Analysis of Insulation Condition in High Voltage Motor Model Coils (고압전동기 모델 코일의 절연상태 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Byeong-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1612-1614
    • /
    • 2003
  • 80pF capacitive couplers were connected to six 6.6kV motor model coil terminals. The voltage applied to the coils were 3.81kv, 4.76 kV and 6.6kV, respectively. These stator coils have various types of artificial insulation defects such as large voids, semi-conductive coating damage and strand insulation fault. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in PD were measured with a conventional digital PD detector. Most of the defect mechanism of large motor stator winding can be associated with PD patterns such as internal and slot discharges. PD patterns coincide with PDD and TGA. These instruments have an input bandwidth of 40-400kHz and 0.1-350MHz. Surge testing detects faults in inter-turn winding of high voltage motor model coils.

  • PDF