• Title/Summary/Keyword: Turbo spin echo

Search Result 40, Processing Time 0.031 seconds

Depiction of Acute Stroke Using 3-Tesla Clinical Amide Proton Transfer Imaging: Saturation Time Optimization Using an in vivo Rat Stroke Model, and a Preliminary Study in Human

  • Park, Ji Eun;Kim, Ho Sung;Jung, Seung Chai;Keupp, Jochen;Jeong, Ha-Kyu;Kim, Sang Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To optimize the saturation time and maximizing the pH-weighted difference between the normal and ischemic brain regions, on 3-tesla amide proton transfer (APT) imaging using an in vivo rat model. Materials and Methods: Three male Wistar rats underwent middle cerebral artery occlusion, and were examined in a 3-tesla magnetic resonance imaging (MRI) scanner. APT imaging acquisition was performed with 3-dimensional turbo spin-echo imaging, using a 32-channel head coil and 2-channel parallel radiofrequency transmission. An off-resonance radiofrequency pulse was applied with a Sinc-Gauss pulse at a $B_{1,rms}$ amplitude of $1.2{\mu}T$ using a 2-channel parallel transmission. Saturation times of 3, 4, or 5 s were tested. The APT effect was quantified using the magnetization-transfer-ratio asymmetry at 3.5 ppm with respect to the water resonance (APT-weighted signal), and compared with the normal and ischemic regions. The result was then applied to an acute stroke patient to evaluate feasibility. Results: Visual detection of ischemic regions was achieved with the 3-, 4-, and 5-s protocols. Among the different saturation times at $1.2{\mu}T$ power, 4 s showed the maximum difference between the ischemic and normal regions (-0.95%, P = 0.029). The APTw signal difference for 3 and 5 s was -0.9% and -0.7%, respectively. The 4-s saturation time protocol also successfully depicted the pH-weighted differences in an acute stroke patient. Conclusion: For 3-tesla turbo spin-echo APT imaging, the maximal pH-weighted difference achieved when using the $1.2{\mu}T$ power, was with the 4 s saturation time. This protocol will be helpful to depict pH-weighted difference in stroke patients in clinical settings.

The Latest Trend of Dynamic MR Defecography for the Chronic Constipation Patient (만성 기능성 변비 환자에서 동적 MR Defecography의 최신동향)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.17-21
    • /
    • 2004
  • With advancement of the medical imaging technology, the dynamic pelvic MRI (magnetic resonance imaging) has been introduced and used for dynamic MR defecography to improved diagnosis of the patients. At the early stage of its use, it was mostly used to diagnose enterocele or cystocele, then its use was extended to diagnose the organ prolapse and other dysfunctional pelvis organs. There now have been many reports of other diseases such as the functional constipation and others. This paper introduces the pelvis MRI and the dynamic MR defecography and reports the future trend in their clinical applications. Until recently, the studies with pelvic MRI were mostly focused on observing the movement of the pelvis in the supine position. Yang and 26 others reported good result in observing the patients with the pelvic organ prolapse by using the pubococcygeal line as the anatomical index. Using the fast gradient recalled acquisition (fast GRASS), they compared cystocoele, genitourinary prolapse, enterocoele and rectocoele with the control group. Kruyt et al. observed the posterior compartment and reported that MRI was more helpful than the fluoroscopy. Healy et al. applied the dynamic MRI test on the patients with constipation or incontinence as well as the control group without those symptoms. Since then, MRI technology has further advance by Lienemann, who was able to attain the more detailed images using the fast T2 weighted turbo spin echo technology, and others. If its limitation in diagnosing intussusception and the like, since the observation can be made only from the supine position, can be overcome with open MR or others, it is envisages that the method can eventually replace the radiological defecography.

  • PDF

The Evaluation of Optimized Inversion-Recovery Fat-Suppression Techniques for T2-Weighted Abdominal MR Imaging : Preliminary report (복부의 T2강조 영상에서 지방소거기법의최적의 평가)

  • Lee, Da-Hee;Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.31-35
    • /
    • 2012
  • To test the real image quality of a spectral attenuated inversion-recovery (SPAIR) fat-suppression (FS) techniquein clinical abdominal MRI by comparison to turbo spin echo inversion-recovery (TSEIR) fat-suppression (FS) technique. 3.0T MRI studies of the abdomen were performed in 30 patients with liver lesions (hemangiomas n: 15; HCC n: 15). T2W sequences were acquired using SPAIR TSEIR. Measurements included retroperitoneal and mesenteric fat signal-to-noise (SNR) to evaluate FS; liver lesion contrast-to-noise (CNR) to evaluate bulk water signal recovery effects; and bowel wall delineation to evaluate susceptibility and physiological motion effects. SPAIR-TSEIR images produce significantly improved FS and liver lesion CNR. The mean SNR of the retroperitoneal and mesenteric fat for SPAIR were 20.5, 10.2 and TSEIR were 43.2, 24.1 (P<0.05). SPAIR-TSEIR images produced higher CNR for both hemangiomas CNR 164.88 vs 126.83 (P<0.05) and metastasis CNR 75.27 vs 53.19 (P<0.05). Bowel wall visualization was significantly improved using in both SPAIR-TSEIR (P< 0.05). The real image quality of SPAIR was better than over conventional TSEIR FS on clinical abdominal MRI scans.

  • PDF

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

Optimal Flip Angle for T2-Weighted Effect in Micro 4.7T MRI SE Sequence (마이크로 4.7T MRI SE Sequence에서 T2강조효과를 위한 최적의 Flip Angle)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.113-117
    • /
    • 2019
  • The purpose of this study was to investigate the FA value which can produce the best T2-weighted images by measuring the signal intensity and noise according to the FA value change in the brain image and the abdominal image of the mouse using micro-MRI. Brain imaging and abdominal imaging of BALB / C mice weighing 20g were performed using 4.7T (Bruker BioSpin MRI GmbH) micro-MRI equipment, Turbo RARE-T2 (spin echo-T2) images were scanned at TR 3500 msec and TE 36 msec. The changes of the FA values were $60^{\circ}$, $80^{\circ}$, $100^{\circ}$, $120^{\circ}$, $140^{\circ}$, $160^{\circ}$ and $180^{\circ}$. We measured signal intensity according to FA values of ventricle and thalamus in brain imaging, The signal intensity of kidney and muscle around the kidney was measured in abdominal images. To obtain SNR and CNR, we measured the background signals of two different parts, not the tissue. In the brain (thalamus) image, the signal intensity of FA $100^{\circ}$ was 7,433 and SNR (6.49) was the highest. In the abdominal (kidney) image, the signal intensity was highest at 16,523 when FA was $120^{\circ}$, and the highest SNR was 8.54 when FA was $140^{\circ}$. The CNR value of the brain image was 1.38 at FA $60^{\circ}$ and gradually increased to 8.29 at FA $180^{\circ}$. The CNR value of the muscle adjacent to the kidney gradually increased from 2.36 when the FA value was $60^{\circ}$ and the highest value was 4,57 at the FA value $180^{\circ}$.

Chemical Saturation Breath-hold Fast MR Imaging for characterization of Regional Fatty Changes in Liver (화학적 포화 호흡정지 급속 자기공명영상에서 국소적 간지방병변의 특성화)

  • 김동국;유정식;김태훈;오세정;김지형
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.135-141
    • /
    • 1997
  • Purpose: To assess the usefulness of breath-hold fast MR imaging of liver with fat suppression (FS) by application of chemical saturation technique in the diagnosis of regional fatty changes suspected in sonography. Materials and Methods: Thirteen patients who had focal lesions with diffuse, homogeneous signal changes after FS through chemical saturation technique without additional changes of imaging parameter during MR imaging of liver were selected. T1-weighted fast low-angle shot and T2-weighted turbo spin-echo sequences were obtained with or without FS during each single breath-holding session. Subjective changes of signal intensity between the pre-FS and the FS images were compared with the sonographic findings in each lesion. Results: Seven lesions of decreased signal intensity after FS on T1 or T2-weighted images, including three lesions only at FS T1 images, were regarded as focal fat infiltration. All seven lesions had compatible sonographic findings as homogenously echogenic areas. Another six lesions of subjectively increased signal intensity including two lesions only at FS T2 images were regarded as focal fat sparing. All six lesions had sonographic findings as homogenous echo poor areas suggesting focal fat sparing. In cases regarded as fat infiltration, score changes were more prominent at FS T1 images than FS T2 images(p=0.0002). In cases regarded as fat sparing, score changes were more prominent at FS T2 images than FS T1 images(p=0.042). Conclusion: Breath-hold fast T1 and T2-weighted MR imaging with and without chemical saturation pre-pulse may be sufficient for characterization of regional fatty changes in the differential diagnosis of focal hepatic lesion found at sonography.

  • PDF

Comparative Study on Usefulness of SPAIR and STIR Fast SE T2-weighted 3T Magnetic Resonance Imaging (3T 고속스핀에코 T2강조영상에서 지방소거 반전회복기법의 유용성 연구 - SPAIR와 STIR와의 비교 -)

  • Lee, Hoo-Min;Yoon, Joon;Yeo, Young-Bok
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2010
  • In this study, we compared the clinical usefulness of SPAIR (Spectral Adiabatic Inversion Recovery) and STIR (Short TI Inversion Recovery) to evaluate the fat tissues precisely. The images of brain axial (n = 20), lumber spine sagittal (n = 20), hip joint coronal (n = 17) and knee joint (n = 25) were obtained by turbo spin echo T2 weighted method on 3T magnetic resonance image. The signal intensity (SI) values were measured using region of interest in fat, muscle tissue, and background noise. The inhomogeneity values were measured using the standard deviation (SD) value divided by the mean values. SD signifies the amount of error which is similar to the imaging heterogeneity. In brain axial images, the SPAIR showed more superior SI and inhomogeneity results than the STIR. In spine, hip and knee images, STIR showed more excellent SI results, but poor inhomogeneity than the SPAIR.

Quantitative Evaluation of Optimized Fat-Suppression Techniques for T1 Weighted Cervical Spine MR Imaging: Comparison of TSE-CHESS and TSE-SPAIR (T1 강조 경추자기공명영상에 대한 최적의 지방소거기법의 정량적 평가: TSE-CHESS 과 TSE-SPAIR 의 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.529-536
    • /
    • 2013
  • The purpose of this study is to know clinical usefulness for fat suppression of the body curved portion compared with TSE-CHESS and TSE-SPAIR technique. A total of 25 normal volunteers without cervical spine disease were studied on a 3.0 T MRI scanner. As a quantitative analysis, PSNRs and CNRs were evaluated by using two methods for fat suppression of the body curved portion. As a results, PSNRs and CNRs for fat suppression were significantly greater for the TSE-SPAIR technique compared to TSE-CHESS technique. In conclusion, this study showed that a TSE-SPAIR technique has improved PSNRs and CNRs for evaluating of fat suppression in the body curved portion. These conclusions in the future will be provided information in diagnosis of fat suppression for the body curved portion.

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

Added Predictive Values of Proton Density Magnetic Resonance Imaging on Posterior Communicating Artery Aneurysms and Surrounding Soft Tissues with Simple Classification

  • Sun Yoon;Min Jeoung Kim;Hyun Jin Han;Keun Young Park;Joonho Chung;Yong Bae Kim
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.4
    • /
    • pp.418-425
    • /
    • 2023
  • Objective : Deciphering the anatomy of posterior communicating artery (PCoA) aneurysms in relation to surrounding structures is essential to determine adjuvant surgical procedures. However, it is difficult to predict surgical structures through preoperative imaging studies. We aimed to present anatomical structures using preoperative high-resolution three-dimensional proton density-weighted turbo spin-echo magnetic resonance (PDMR) imaging with simple classification. Methods : From January 2020 to April 2022, 30 patients underwent PDMR before microsurgical clipping for unruptured PCoA aneurysms in a single tertiary institute. We retrospectively reviewed the radiographic images and operative data of these patients. The structural relationship described by PDMR and intraoperative findings were compared. Subsequently, we classified aneurysms into two groups and analyzed the rate of adjuvant surgical procedures and contact with the surrounding structures. Results : Correlations between preoperative PDMR predictions and actual intraoperative findings for PCoA aneurysm contact to the oculomotor nerve, temporal uncus, and anterior petroclinoid fold (APCF) reported a diagnostic accuracy of 0.90, 0.87, and 0.90, respectively. In 12 patients (40.0%), an aneurysm dome was located on the plane of the oculomotor triangle and was classified as the infratentorial type. Compared to the supratentorial type PCoA aneurysm, adjuvant procedures were required more frequently (66.7% vs. 22.2%, p=0.024) for infratentorial type PCoA aneurysm clipping. Conclusion : Preoperative PCoA aneurysm categorization using PDMR can be helpful for predicting surgical complexity and planning of microsurgical clipping.