• Title/Summary/Keyword: Turbine-generator

Search Result 990, Processing Time 0.035 seconds

Understanding Governor Droop of Turbine-Generator through Graph and Proportional Expression (터빈-발전기 Governor Droop의 그래프와 비례식을 통한 특성 고찰)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.33-38
    • /
    • 2013
  • This paper presents a simpler calculation of the generator load sharing according to the change of system frequency and the droop setting of turbine-generator governor. The author firstly draws a graph based on the generator operation at rated MW output and normal frequency, and secondly, builds a proportional expression using the graph in order to obtain the solution in a simpler way rather than using conventional mathematical calculation, to provide the readers with an easier understanding of the droop setting of turbine-generator governor.

Hydrogen Peroxide Gas Generator Design and Investigation of Power Measurement Method Utilizing Turbocharger (과산화수소 가스발생기 설계와 터보차저를 이용한 동력 측정 방법 검토)

  • Park, Dae-Jong;An, Sung-Yong;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.41-44
    • /
    • 2008
  • In this paper, the gas generator using hydrogen peroxide catalytic decomposition was designed for turbine generator operation. The gas generator used 90wt% rocket-grade of hydrogen peroxide and manganese dioxide as a catalyst. Turbine generators utilizing gas generators were investigated and the prestudy was prepared using automobile turbocharger instead of turbine generator.

  • PDF

A Sensitivity and Performance Analysis for Torque Mode Switching on 2MW Direct Drive Wind Turbine Generator (2MW급 직접구동형 풍력발전기의 풍황 민감도 및 토크모드 스위칭 성능 해석)

  • Rho, Joo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1455-1460
    • /
    • 2014
  • Wind turbine generators were designed on general regulations of wind condition. At real situations, it could be different from the design conditions. There are many control methods and definitions of transient region, because an efficient wind turbine generator control logic is the important matter in generator performance and annual energy production at real conditions. In this document, the power generation sensitivity for wind speed and turbulence intensities was defined to know the sensitive transient region. Wind conditions are applied for the ranges of 7~10m/s mean wind speed and 14~20% turbulence intensity. The sensibility of HR-D86 wind generator was increased in transient region(8~10m/s) on power curve diagram through a torque control to a pitch control. And then GH-bladed simulations was performed for performance analysis of the torque mode switching in transient region on 2MW direct drive wind generator(HR-D86) which is designed IEC class II for onshore. Through the sensitivity and performance analysis, the sensitivity for real wind condition could be the performance index for an wind generator. And the torque mode switching in transient region can increase the mean power generation on HR-D86 wind turbine generator.

Hot Firing Tests of a Gas Generator for Liquid Rocket Engine using a Turbine Manifold Simulator (터빈 매니폴드 모사장치를 이용한 액체로켓엔진 가스발생기 연소시험)

  • Lim, Byoungjik;Kim, Munki;Kim, Jonggyu;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.22-30
    • /
    • 2015
  • A gas generator which generates turbine driving gas by burning a part of propellants is used in an open cycle liquid rocket engine and as a main component of an open cycle liquid rocket engine autonomous hot firing tests are required to investigate the combustion performance and characteristics of the gas generator. However, since the combustion gas generated by a gas generator is choked at the turbine nozzle in the turbine manifold, it is necessary to consider the internal volume of turbine manifold as well as that of the gas generator for correct investigation of the combustion performance, characteristics, and acoustic characteristics of the gas generator. Therefore, in the paper hot firing test results of a gas generator with a turbine manifold simulator are described and characteristic prediction using the autonomous test of a gas generator is explained.

A Study on the Operational Characteristics of a Squirrel-cage type Wind Turine Induction Generator (농형 풍력 유도발전기의 운전 특성에 관한 연구)

  • Jang, Sung-Il;Jeong, Jong-Chan;Choi, Jeong-Hwan;Park, Je-Young;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1309-1312
    • /
    • 2002
  • The electric power network paralleled with wind turbine generator may have the negative impacts on the protection, operation, and management caused by the operation of wind turbine generator. Therefore, it is necessary to investigate the operating characteristic of wind turbine generator. This paper describes model of a squirrel-cage type wind turbine induction generator and the soft cut-in connection method for reducing the transient state on power network, and simulates various cases of wind turbine operations. The radial distribution network of IEEE 13-bus are modeled and tested by PSCAD/EMTDC.

  • PDF

Seismic Response Analysis of Steam Turbine-Generator Rotor System(1st Report, In case of rotor-bearing system only) (증기터빈$\cdot$발전기축계의 지진응답해석(제 1 보, 로터$\cdot$베어링시스템만을 고려한 경우))

  • 양보석;김용한
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.554-564
    • /
    • 1999
  • This paper presents the analytical method to evaluate the seismic responses on steam turbine-generator rotor system. Deterministic analytical methods, such as response spectrum approach, modal superposition method and direct integration method, are used to calculate the seismic response. The computer software is also developed based on the methods then can be applied to estimate the seismic safety of turbine-generator rotor system for power plants. Numerical example of a steam turbine-generator rotor system of 1007MW nuclear power plant is presented. The aseismatic performance are checked by comparing maximum seismic deflection at bearing positions with bearing clearance.

  • PDF

A comparison of speed control of various turbines according to power plant types (발전방식별 여러 가지 터빈의 속도제어 비교)

  • Choi, I.K.;Jeong, C.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2314-2316
    • /
    • 2001
  • The steam gererator which produces thermal energy from coal or gas is a very important device in power plants, including the turbine driving synchronous generator which transforms kinetic energy into electrical energy. The turbine and the generator are driven by many kinds of media according to the types of which power plants are classified into steam turbine generator, gas turbine generator, water turbine generator and so on. This paper introduces the overspeed protection as well as the various speed and load control methods of some types of turbines.

  • PDF

A simulation test of lone rejection for steam turbine generator in nuclear power plant (원자력발전소 증기터빈 발전기의 부하차단 모의시험)

  • Choi, In-Kyu;Jeong, Tae-Woon;Lee, Ki-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2301-2303
    • /
    • 2003
  • A steam turnine in thermal/nuclear power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy. After synchronization in parallel with the power system, generator output increases according as the governor, that is the controller, increases steam flow into turbine. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip setpoint by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a simulation test of generator load rejection to be implemented on the turbine governor in a 600MW nuclear power plant before its startup.

  • PDF

Analysis of Shorted Turns in Turbine Generator Rotor Windings (터빈 발전기 회전자 권선의 층간단락 분석)

  • Kim, Hee-Dong;Kim, Byeong-Rae;Choi, Hyung-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1555-1559
    • /
    • 2011
  • Turbine generator(13.8 kV, 137.5 MW) has high bearing vibration at rotation speed. Shorted turns in generator rotor windings have strong correlation with increased field current which is thus related to increase in bearing vibration. The recurrent surge oscillograph (RSO) test is performed on the rotor winding in turbine generator to detect shorted turns. The result of the RSO test indicates that shorted turns of rotor winding are generated in two locations. The RSO test was capable of identifying the presence, number, and location of shorted turns in generator rotor windings.

Analysis of Dynamic Characteristics for Doubly-Fed Induction Generator in Wind Turbine System based on Stiffness of Linked System (연계계통의 강인성에 따른 이중여자유도발전 풍력시스템의 동특성 해석)

  • Kim, Tae-Ho;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.458_459
    • /
    • 2009
  • This paper analyzes the dynamic characteristics for doubly-fed induction generator(DFIG) in wind turbine system. This paper presents a modeling and simulation of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink, and analyzes the responses DFIG wind turbine system for stiffness of linked system. Simulation results show the variations of generator's active/reactive output, terminal voltage, fault current, etc.

  • PDF